Age | Commit message (Collapse) | Author | Files | Lines |
|
The timer driver subsystem does not need any extra data, so it can use
`struct fdt_driver` directly. The generic fdt_timer_init() performs a
best-effort initialization of all matching DT nodes.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
Now that driver lifecycle is managed from within the SBI timer core,
platforms need only to initialize the driver once during cold init.
Remove the remaining platform hooks that are no longer used.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
Currently, the platform's timer device is tracked in two places: the
core SBI implementation has `timer_dev`, and the FDT timer layer has
`current_driver`. The latter is used for warm initialization of the
timer device. However, this warm init is not specific to FDT-based
platforms; other platforms call exactly the same functions from the
same point in the boot sequence.
The code is simplified and made common across platforms by treating warm
init and exit as properties of the driver, not the platform. Then the
platform's only role is to select and prepare a driver during cold boot.
For now, only add a .warm_init hook, since none of the existing drivers
need an .exit hook. It could be added in the future if needed.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
Indicate that none of these functions modify the devicetree by
constifying the parameter type.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Andrew Jones <ajones@ventanamicro.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
The parser will fail if the timer is clint timer and has regname
property. As the regname is only meaningful for aclint, it is more
robust to only check regname for aclint timer.
Fixes: 6112d58 ("lib: utils/fdt: Allow to use reg-names when parsing ACLINT")
Signed-off-by: Inochi Amaoto <inochiama@outlook.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
T-HEAD allows soc vendor to map the mtimer and mswi of C9xx clint on
different address, which may cause a misuse if use the same compatible
string, add a new timer compatible string to avoid this.
Signed-off-by: Inochi Amaoto <inochiama@outlook.com>
Link: https://lore.kernel.org/linux-riscv/6e48cbe5e60f9ada2fd1fe58e803e127f1a678e5.1696433229.git.unicorn_wang@outlook.com/
Reviewed-by: Guo Ren <guoren@kernel.org>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
The quirks checking will cause ACLINT step into a CLINT code path, this
is not expected when ACLINT needs custom quirks.
Add a new quirk to identify custom ACLINT, and apply the general quirks
after applying CLINT specific quirks.
Signed-off-by: Inochi Amaoto <inochiama@outlook.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
Let's use heap allocation in ACLINT MTIMER driver instead of using
a fixed size global array.
Signed-off-by: Anup Patel <apatel@ventanamicro.com>
Reviewed-by: Andrew Jones <ajones@ventanamicro.com>
|
|
As we already added the quirk for lacking mtime register to MTIMER
driver, add T-Head C9xx CLINT compatible to it and wire the quirk.
Signed-off-by: Icenowy Zheng <uwu@icenowy.me>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
T-Head developers surely have a different understanding of time CSR and
CLINT's mtime register with SiFive ones, that they did not implement
the mtime register at all -- as shown in openC906 source code, their
time CSR value is just exposed at the top of their processor IP block
and expects an external continous counter, which makes it not
overrideable, and thus mtime register is not implemented, even not for
reading. However, if CLINTEE is not enabled in T-Head's MXSTATUS
extended CSR, these systems still rely on the mtimecmp registers to
generate timer interrupts. This makes it necessary to implement T-Head
C9xx CLINT support in OpenSBI MTIMER driver, which skips implementing
reading mtime register and falls back to default code that reads time
CSR.
Add a quirk into MTIMER driver, which represents a mtime register is
lacking and time CSR value should be used instead.
Signed-off-by: Icenowy Zheng <uwu@icenowy.me>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
The allwinner,sun20i-d1-clint compatible string is not documented in any
official binding, so it should not be used by drivers.
The MSWI in the D1 CLINT is compatible with the ACLINT specification, so
it can take advantage of generic driver support. However, that is only
possible if the MSWI and MTIMER are split into separate DT nodes. This
means the final binding for this device is likely to be incompatible
with what is implemented here.
Remove this compatible string from the driver to prevent it from
appearing in a stable version and causing future issues.
Signed-off-by: Samuel Holland <samuel@sholland.org>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
The CLINT in the Allwinner D1 SoC apparently does not support 64-bit
MMIO access. A property was added to support this quirk (and that
property was copied to the ACLINT MTIMER code). However, since this
difference in behavior makes the D1 CLINT incompatible with the SiFive
CLINT's programming interface, a better solution is to use a separate
compatible string.
Signed-off-by: Samuel Holland <samuel@sholland.org>
Reviewed-by: Anup Patel <anup@brainfault.org>
|
|
Match data stores hardware attributes which do not change at runtime, so
it does not need to be mutable. Make it const.
Reviewed-by: Guo Ren <guoren@kernel.org>
Reviewed-by: Xiang W <wxjstz@126.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
Signed-off-by: Samuel Holland <samuel@sholland.org>
|
|
Generic mdelay() and udelay() functions can be provided by the
sbi_timer framework if timer frequency is available in the timer
instance provided by the platform support or timer driver.
This patch adds timer frequency (timer_freq) member in the
struct sbi_timer_device for above purpose.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Xiang W <wxjstz@126.com>
|
|
We simplify MTIMER synchronization as follows:
1) Detect MTIMER devices with unique (or non-shared) MTIME
register at boot-time
2) Select first MTIMER device with no associated HART as our
reference MTIMER device
3) Only synchronize MTIMER devices with unique (or non-shared)
MTIME register using reference MTIMER device
4) Directly update the MTIME register at time of synchronization
because MTIME is a read/write register.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>
|
|
We can have ACLINT MTIMER devices which only support 32-bit MMIO
accesses on RV64 system so this patch adds a boolean DT property
"mtimer,no-64bit-mmio" to detect this from MTIMER DT node.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>
|
|
The fdt_parse_aclint_node() is used to parse DT node for SiFive
CLINT, ACLINT MTIMER, and ACLINT MSWI devices.
The ACLINT MTIMER has undergone following changes:
1) MTIMER DT node now requires separate addresses in for MTIME
register and MTIMECMPx registers in the reg DT property.
2) MTIMER DT node might have no interrupts-extended DT property
when the MTIMER device has no associated HARTs (i.e. the
MTIMER device has no MTIMECMPx registers)
This patch extends fdt_parse_aclint_node() to handle above
mentioned changes in ACLINT MTIMER DT bindings.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>
|
|
We extend the ACLINT library to support separate base addresses
for MTIME and MTIMECMP registers.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>
|
|
We add a new FDT based ACLINT MTIMER driver which works for
both CLINT device and standalone ACLINT MTIMER device.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Xiang W <wxjstz@126.com>
|