blob: 03d054b2bf9af5244e20c4eb35266c8d103449bb (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
|
/*
* Device Tree Source for OMAP4/5 SoC CPU thermal
*
* Copyright (C) 2013 Texas Instruments Incorporated - https://www.ti.com/
* Contact: Eduardo Valentin <eduardo.valentin@ti.com>
*
* This file is licensed under the terms of the GNU General Public License
* version 2. This program is licensed "as is" without any warranty of any
* kind, whether express or implied.
*/
#include <dt-bindings/thermal/thermal.h>
cpu_thermal: cpu_thermal {
polling-delay-passive = <250>; /* milliseconds */
polling-delay = <1000>; /* milliseconds */
/* sensor ID */
thermal-sensors = <&bandgap 0>;
cpu_trips: trips {
cpu_alert0: cpu_alert {
temperature = <100000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "passive";
};
cpu_crit: cpu_crit {
temperature = <125000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "critical";
};
};
cpu_cooling_maps: cooling-maps {
map0 {
trip = <&cpu_alert0>;
cooling-device =
<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
};
|