1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
|
# SPDX-License-Identifier: GPL-2.0
%YAML 1.2
---
$id: http://devicetree.org/schemas/regulator/pwm-regulator.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#
title: Generic PWM Regulator
maintainers:
- Brian Norris <briannorris@chromium.org>
- Lee Jones <lee@kernel.org>
- Alexandre Courbot <acourbot@nvidia.com>
description: |
Currently supports 2 modes of operation:
Voltage Table:
When in this mode, a voltage table (See below) of predefined voltage <=>
duty-cycle values must be provided via DT. Limitations are that the
regulator can only operate at the voltages supplied in the table.
Intermediary duty-cycle values which would normally allow finer grained
voltage selection are ignored and rendered useless. Although more control
is given to the user if the assumptions made in continuous-voltage mode do
not reign true.
Continuous Voltage:
This mode uses the regulator's maximum and minimum supplied voltages
specified in the regulator-{min,max}-microvolt properties to calculate
appropriate duty-cycle values. This allows for a much more fine grained
solution when compared with voltage-table mode above. This solution does
make an assumption that a %50 duty-cycle value will cause the regulator
voltage to run at half way between the supplied max_uV and min_uV values.
If voltage-table is provided, then the device will be used in Voltage Table
Mode. If no voltage-table is provided, then the device will be used in
Continuous Voltage Mode.
allOf:
- $ref: regulator.yaml#
properties:
compatible:
const: pwm-regulator
pwms:
maxItems: 1
voltage-table:
description: Voltage and Duty-Cycle table.
$ref: /schemas/types.yaml#/definitions/uint32-matrix
items:
items:
- description: voltage in microvolts (uV)
- description: duty-cycle in percent (%)
enable-gpios:
description: Regulator enable GPIO
maxItems: 1
# Optional properties for Continuous mode:
pwm-dutycycle-unit:
description:
Integer value encoding the duty cycle unit. If not
defined, <100> is assumed, meaning that
pwm-dutycycle-range contains values expressed in
percent.
default: 100
pwm-dutycycle-range:
description:
Should contain 2 entries. The first entry is encoding
the dutycycle for regulator-min-microvolt and the
second one the dutycycle for regulator-max-microvolt.
Duty cycle values are expressed in pwm-dutycycle-unit.
If not defined, <0 100> is assumed.
$ref: /schemas/types.yaml#/definitions/uint32-array
items:
- description: the dutycycle for regulator-min-microvolt
- description: the dutycycle for regulator-max-microvolt
default: [ 0 100 ]
required:
- compatible
- pwms
unevaluatedProperties: false
examples:
- |
#include <dt-bindings/gpio/gpio.h>
// Continuous Voltage With Enable GPIO Example:
regulator {
compatible = "pwm-regulator";
pwms = <&pwm1 0 8448 0>;
enable-gpios = <&gpio0 23 GPIO_ACTIVE_HIGH>;
regulator-min-microvolt = <1016000>;
regulator-max-microvolt = <1114000>;
regulator-name = "vdd_logic";
/* unit == per-mille */
pwm-dutycycle-unit = <1000>;
/*
* Inverted PWM logic, and the duty cycle range is limited
* to 30%-70%.
*/
pwm-dutycycle-range = <700 300>; /* */
};
- |
// Voltage Table Example:
regulator {
compatible = "pwm-regulator";
pwms = <&pwm1 0 8448 0>;
regulator-min-microvolt = <1016000>;
regulator-max-microvolt = <1114000>;
regulator-name = "vdd_logic";
/* Voltage Duty-Cycle */
voltage-table = <1114000 0>,
<1095000 10>,
<1076000 20>,
<1056000 30>,
<1036000 40>,
<1016000 50>;
};
...
|