What: /sys/class/power_supply/max1720x/temp_ain1
Date: January 2025
KernelVersion: 6.14
Contact: Dimitri Fedrau <dimitri.fedrau@liebherr.com>
Description:
Reports the current temperature reading from AIN1 thermistor.
Access: Read
Valid values: Represented in 1/10 Degrees Celsius
What: /sys/class/power_supply/max1720x/temp_ain2
Date: January 2025
KernelVersion: 6.14
Contact: Dimitri Fedrau <dimitri.fedrau@liebherr.com>
Description:
Reports the current temperature reading from AIN2 thermistor.
Access: Read
Valid values: Represented in 1/10 Degrees Celsius
What: /sys/class/power_supply/max1720x/temp_int
Date: January 2025
KernelVersion: 6.14
Contact: Dimitri Fedrau <dimitri.fedrau@liebherr.com>
Description:
Reports the current temperature reading from internal die.
Access: Read
Valid values: Represented in 1/10 Degrees Celsius
|