diff options
Diffstat (limited to 'drivers/acpi/processor_thermal.c')
| -rw-r--r-- | drivers/acpi/processor_thermal.c | 71 | 
1 files changed, 0 insertions, 71 deletions
diff --git a/drivers/acpi/processor_thermal.c b/drivers/acpi/processor_thermal.c index 419f651b63f3..fde49b9b1d99 100644 --- a/drivers/acpi/processor_thermal.c +++ b/drivers/acpi/processor_thermal.c @@ -44,47 +44,6 @@  #define _COMPONENT              ACPI_PROCESSOR_COMPONENT  ACPI_MODULE_NAME("processor_thermal"); -/* -------------------------------------------------------------------------- -                                 Limit Interface -   -------------------------------------------------------------------------- */ -static int acpi_processor_apply_limit(struct acpi_processor *pr) -{ -	int result = 0; -	u16 px = 0; -	u16 tx = 0; - - -	if (!pr) -		return -EINVAL; - -	if (!pr->flags.limit) -		return -ENODEV; - -	if (pr->flags.throttling) { -		if (pr->limit.user.tx > tx) -			tx = pr->limit.user.tx; -		if (pr->limit.thermal.tx > tx) -			tx = pr->limit.thermal.tx; - -		result = acpi_processor_set_throttling(pr, tx, false); -		if (result) -			goto end; -	} - -	pr->limit.state.px = px; -	pr->limit.state.tx = tx; - -	ACPI_DEBUG_PRINT((ACPI_DB_INFO, -			  "Processor [%d] limit set to (P%d:T%d)\n", pr->id, -			  pr->limit.state.px, pr->limit.state.tx)); - -      end: -	if (result) -		printk(KERN_ERR PREFIX "Unable to set limit\n"); - -	return result; -} -  #ifdef CONFIG_CPU_FREQ  /* If a passive cooling situation is detected, primarily CPUfreq is used, as it @@ -107,36 +66,6 @@ static int cpu_has_cpufreq(unsigned int cpu)  	return 1;  } -static int acpi_thermal_cpufreq_increase(unsigned int cpu) -{ -	if (!cpu_has_cpufreq(cpu)) -		return -ENODEV; - -	if (per_cpu(cpufreq_thermal_reduction_pctg, cpu) < -		CPUFREQ_THERMAL_MAX_STEP) { -		per_cpu(cpufreq_thermal_reduction_pctg, cpu)++; -		cpufreq_update_policy(cpu); -		return 0; -	} - -	return -ERANGE; -} - -static int acpi_thermal_cpufreq_decrease(unsigned int cpu) -{ -	if (!cpu_has_cpufreq(cpu)) -		return -ENODEV; - -	if (per_cpu(cpufreq_thermal_reduction_pctg, cpu) > -		(CPUFREQ_THERMAL_MIN_STEP + 1)) -		per_cpu(cpufreq_thermal_reduction_pctg, cpu)--; -	else -		per_cpu(cpufreq_thermal_reduction_pctg, cpu) = 0; -	cpufreq_update_policy(cpu); -	/* We reached max freq again and can leave passive mode */ -	return !per_cpu(cpufreq_thermal_reduction_pctg, cpu); -} -  static int acpi_thermal_cpufreq_notifier(struct notifier_block *nb,  					 unsigned long event, void *data)  {  | 
