diff options
Diffstat (limited to 'arch/s390/kernel/runtime_instr.c')
-rw-r--r-- | arch/s390/kernel/runtime_instr.c | 64 |
1 files changed, 3 insertions, 61 deletions
diff --git a/arch/s390/kernel/runtime_instr.c b/arch/s390/kernel/runtime_instr.c index 26b4ae96fdd7..fffa0e5462af 100644 --- a/arch/s390/kernel/runtime_instr.c +++ b/arch/s390/kernel/runtime_instr.c @@ -18,11 +18,6 @@ /* empty control block to disable RI by loading it */ struct runtime_instr_cb runtime_instr_empty_cb; -static int runtime_instr_avail(void) -{ - return test_facility(64); -} - static void disable_runtime_instr(void) { struct pt_regs *regs = task_pt_regs(current); @@ -40,7 +35,6 @@ static void disable_runtime_instr(void) static void init_runtime_instr_cb(struct runtime_instr_cb *cb) { cb->buf_limit = 0xfff; - cb->int_requested = 1; cb->pstate = 1; cb->pstate_set_buf = 1; cb->pstate_sample = 1; @@ -57,46 +51,14 @@ void exit_thread_runtime_instr(void) return; disable_runtime_instr(); kfree(task->thread.ri_cb); - task->thread.ri_signum = 0; task->thread.ri_cb = NULL; } -static void runtime_instr_int_handler(struct ext_code ext_code, - unsigned int param32, unsigned long param64) -{ - struct siginfo info; - - if (!(param32 & CPU_MF_INT_RI_MASK)) - return; - - inc_irq_stat(IRQEXT_CMR); - - if (!current->thread.ri_cb) - return; - if (current->thread.ri_signum < SIGRTMIN || - current->thread.ri_signum > SIGRTMAX) { - WARN_ON_ONCE(1); - return; - } - - memset(&info, 0, sizeof(info)); - info.si_signo = current->thread.ri_signum; - info.si_code = SI_QUEUE; - if (param32 & CPU_MF_INT_RI_BUF_FULL) - info.si_int = ENOBUFS; - else if (param32 & CPU_MF_INT_RI_HALTED) - info.si_int = ECANCELED; - else - return; /* unknown reason */ - - send_sig_info(current->thread.ri_signum, &info, current); -} - -SYSCALL_DEFINE2(s390_runtime_instr, int, command, int, signum) +SYSCALL_DEFINE1(s390_runtime_instr, int, command) { struct runtime_instr_cb *cb; - if (!runtime_instr_avail()) + if (!test_facility(64)) return -EOPNOTSUPP; if (command == S390_RUNTIME_INSTR_STOP) { @@ -106,8 +68,7 @@ SYSCALL_DEFINE2(s390_runtime_instr, int, command, int, signum) return 0; } - if (command != S390_RUNTIME_INSTR_START || - (signum < SIGRTMIN || signum > SIGRTMAX)) + if (command != S390_RUNTIME_INSTR_START) return -EINVAL; if (!current->thread.ri_cb) { @@ -120,7 +81,6 @@ SYSCALL_DEFINE2(s390_runtime_instr, int, command, int, signum) } init_runtime_instr_cb(cb); - current->thread.ri_signum = signum; /* now load the control block to make it available */ preempt_disable(); @@ -129,21 +89,3 @@ SYSCALL_DEFINE2(s390_runtime_instr, int, command, int, signum) preempt_enable(); return 0; } - -static int __init runtime_instr_init(void) -{ - int rc; - - if (!runtime_instr_avail()) - return 0; - - irq_subclass_register(IRQ_SUBCLASS_MEASUREMENT_ALERT); - rc = register_external_irq(EXT_IRQ_MEASURE_ALERT, - runtime_instr_int_handler); - if (rc) - irq_subclass_unregister(IRQ_SUBCLASS_MEASUREMENT_ALERT); - else - pr_info("Runtime instrumentation facility initialized\n"); - return rc; -} -device_initcall(runtime_instr_init); |