clk: imx6ul: fix enet1 gate configuration
According to the "i.MX 6UltraLite Applications Processor Reference Manual, Rev. 2, 03/2017", BIT(13) is ENET1_125M_EN which is not controlling root of PLL6. It is controlling ENET1 separately. So, instead of this picture (implementation before this patch): fec1 <- enet_ref (divider) <---------------------------, |- pll6_enet (gate) fec2 <- enet2_ref_125m (gate) <- enet2_ref (divider) <-´ we should have this one (after this patch): fec1 <- enet1_ref_125m (gate) <- enet1_ref (divider) <-, |- pll6_enet fec2 <- enet2_ref_125m (gate) <- enet2_ref (divider) <-´ With this fix, the RMII reference clock will be turned off, after setting network interface down on each separate interface (ip l s dev eth0 down). Which was not working before, on system with both FECs enabled. Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de> Reviewed-by: Abel Vesa <abel.vesa@linaro.org> Signed-off-by: Abel Vesa <abel.vesa@linaro.org> Link: https://lore.kernel.org/r/20230131084642.709385-16-o.rempel@pengutronix.de