summaryrefslogtreecommitdiff
path: root/include
diff options
context:
space:
mode:
authorVladimir Oltean <vladimir.oltean@nxp.com>2022-04-22 02:01:05 +0300
committerDavid S. Miller <davem@davemloft.net>2022-04-25 13:47:55 +0300
commit1fcb8fb3522f5b0f1cf0f5c7560cd6629abba0cb (patch)
tree738d868a63f89cfe55a5dcc037b275eda33cb086 /include
parent9323ac367005d6aa4d579311917c636c43206b53 (diff)
downloadlinux-1fcb8fb3522f5b0f1cf0f5c7560cd6629abba0cb.tar.xz
net: mscc: ocelot: don't add VID 0 to ocelot->vlans when leaving VLAN-aware bridge
DSA, through dsa_port_bridge_leave(), first notifies the port of the fact that it left a bridge, then, if that bridge was VLAN-aware, it notifies the port of the change in VLAN awareness state, towards VLAN-unaware mode. So ocelot_port_vlan_filtering() can be called when ocelot_port->bridge is NULL, and this makes ocelot_add_vlan_unaware_pvid() create a struct ocelot_bridge_vlan with a vid of 0 and an "untagged" setting of true on that port. In a way this structure correctly reflects the reality, but by design, VID 0 (OCELOT_STANDALONE_PVID) was not meant to be kept in the bridge VLAN list of the driver, but managed separately. Having OCELOT_STANDALONE_PVID in ocelot->vlans makes us trip up on several sanity checks that did not expect to have this VID there. For example, after we leave a VLAN-aware bridge and we re-join it, we can no longer program egress-tagged VLANs to hardware: # ip link add br0 type bridge vlan_filtering 1 && ip link set br0 up # ip link set swp0 master br0 # ip link set swp0 nomaster # ip link set swp0 master br0 # bridge vlan add dev swp0 vid 100 Error: mscc_ocelot_switch_lib: Port with more than one egress-untagged VLAN cannot have egress-tagged VLANs. But this configuration is in fact supported by the hardware, since we could use OCELOT_PORT_TAG_NATIVE. According to its comment: /* all VLANs except the native VLAN and VID 0 are egress-tagged */ yet when assessing the eligibility for this mode, we do not check for VID 0 in ocelot_port_uses_native_vlan(), instead we just ensure that ocelot_port_num_untagged_vlans() == 1. This is simply because VID 0 doesn't have a bridge VLAN structure. The way I identify the problem is that ocelot_port_vlan_filtering(false) only means to call ocelot_add_vlan_unaware_pvid() when we dynamically turn off VLAN awareness for a bridge we are under, and the PVID changes from the bridge PVID to a reserved PVID based on the bridge number. Since OCELOT_STANDALONE_PVID is statically added to the VLAN table during ocelot_vlan_init() and never removed afterwards, calling ocelot_add_vlan_unaware_pvid() for it is not intended and does not serve any purpose. Fix the issue by avoiding the call to ocelot_add_vlan_unaware_pvid(vid=0) when we're resetting VLAN awareness after leaving the bridge, to become a standalone port. Fixes: 54c319846086 ("net: mscc: ocelot: enforce FDB isolation when VLAN-unaware") Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'include')
0 files changed, 0 insertions, 0 deletions