diff options
author | Tobias Waldekranz <tobias@waldekranz.com> | 2021-07-22 18:55:38 +0300 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2021-07-23 18:32:37 +0300 |
commit | 472111920f1c5fbe103022a4b05bfb37128a2a29 (patch) | |
tree | 68f8f35206681a9b0567b7f2b5353d6465690e28 /drivers/net/ethernet/freescale/dpaa2 | |
parent | 5af84df962dd6699e3972fda7a0c8b579fb3ab04 (diff) | |
download | linux-472111920f1c5fbe103022a4b05bfb37128a2a29.tar.xz |
net: bridge: switchdev: allow the TX data plane forwarding to be offloaded
Allow switchdevs to forward frames from the CPU in accordance with the
bridge configuration in the same way as is done between bridge
ports. This means that the bridge will only send a single skb towards
one of the ports under the switchdev's control, and expects the driver
to deliver the packet to all eligible ports in its domain.
Primarily this improves the performance of multicast flows with
multiple subscribers, as it allows the hardware to perform the frame
replication.
The basic flow between the driver and the bridge is as follows:
- When joining a bridge port, the switchdev driver calls
switchdev_bridge_port_offload() with tx_fwd_offload = true.
- The bridge sends offloadable skbs to one of the ports under the
switchdev's control using skb->offload_fwd_mark = true.
- The switchdev driver checks the skb->offload_fwd_mark field and lets
its FDB lookup select the destination port mask for this packet.
v1->v2:
- convert br_input_skb_cb::fwd_hwdoms to a plain unsigned long
- introduce a static key "br_switchdev_fwd_offload_used" to minimize the
impact of the newly introduced feature on all the setups which don't
have hardware that can make use of it
- introduce a check for nbp->flags & BR_FWD_OFFLOAD to optimize cache
line access
- reorder nbp_switchdev_frame_mark_accel() and br_handle_vlan() in
__br_forward()
- do not strip VLAN on egress if forwarding offload on VLAN-aware bridge
is being used
- propagate errors from .ndo_dfwd_add_station() if not EOPNOTSUPP
v2->v3:
- replace the solution based on .ndo_dfwd_add_station with a solution
based on switchdev_bridge_port_offload
- rename BR_FWD_OFFLOAD to BR_TX_FWD_OFFLOAD
v3->v4: rebase
v4->v5:
- make sure the static key is decremented on bridge port unoffload
- more function and variable renaming and comments for them:
br_switchdev_fwd_offload_used to br_switchdev_tx_fwd_offload
br_switchdev_accels_skb to br_switchdev_frame_uses_tx_fwd_offload
nbp_switchdev_frame_mark_tx_fwd to nbp_switchdev_frame_mark_tx_fwd_to_hwdom
nbp_switchdev_frame_mark_accel to nbp_switchdev_frame_mark_tx_fwd_offload
fwd_accel to tx_fwd_offload
Signed-off-by: Tobias Waldekranz <tobias@waldekranz.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ethernet/freescale/dpaa2')
-rw-r--r-- | drivers/net/ethernet/freescale/dpaa2/dpaa2-switch.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/net/ethernet/freescale/dpaa2/dpaa2-switch.c b/drivers/net/ethernet/freescale/dpaa2/dpaa2-switch.c index 3d021edb78e6..c233e8786e19 100644 --- a/drivers/net/ethernet/freescale/dpaa2/dpaa2-switch.c +++ b/drivers/net/ethernet/freescale/dpaa2/dpaa2-switch.c @@ -1936,7 +1936,7 @@ static int dpaa2_switch_port_bridge_join(struct net_device *netdev, err = switchdev_bridge_port_offload(netdev, netdev, NULL, &dpaa2_switch_port_switchdev_nb, &dpaa2_switch_port_switchdev_blocking_nb, - extack); + false, extack); if (err) goto err_switchdev_offload; |