powerpc/5xxx: Add common mpc5xxx_get_bus_frequency() function
So far, MPC512x used mpc512x_find_ips_freq() to get the bus frequency, while MPC52xx used mpc52xx_find_ipb_freq(). Despite the different clock names (IPS vs. IPB) the code was identical. Use common code for both processor families. Signed-off-by: Wolfgang Denk <wd@denx.de> Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
Diffstat (limited to 'drivers/ata')
-rw-r--r--drivers/ata/pata_mpc52xx.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/ata/pata_mpc52xx.c b/drivers/ata/pata_mpc52xx.c
index 68d27bc70d06..2bc2dbe30e8f 100644
--- a/drivers/ata/pata_mpc52xx.c
+++ b/drivers/ata/pata_mpc52xx.c
@@ -694,7 +694,7 @@ mpc52xx_ata_probe(struct of_device *op, const struct of_device_id *match)
struct bcom_task *dmatsk = NULL;
/* Get ipb frequency */
- ipb_freq = mpc52xx_find_ipb_freq(op->node);
+ ipb_freq = mpc5xxx_get_bus_frequency(op->node);
if (!ipb_freq) {
dev_err(&op->dev, "could not determine IPB bus frequency\n");
return -ENODEV;