hwmon: (aquacomputer_d5next) Add support for Quadro flow sensor pulses
Add support for reading and writing flow sensor pulses value on
the Aquacomputer Quadro. Implemented by Leonard Anderweit [1].
[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/45
Originally-from: Leonard Anderweit <leonard.anderweit@gmail.com>
Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20221126071313.34356-1-savicaleksa83@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/aquacomputer_d5next.rst')
-rw-r--r-- | Documentation/hwmon/aquacomputer_d5next.rst | 3 |
1 files changed, 2 insertions, 1 deletions
diff --git a/Documentation/hwmon/aquacomputer_d5next.rst b/Documentation/hwmon/aquacomputer_d5next.rst index 15226346434d..637bdbc8fcad 100644 --- a/Documentation/hwmon/aquacomputer_d5next.rst +++ b/Documentation/hwmon/aquacomputer_d5next.rst @@ -39,7 +39,7 @@ current. The Quadro exposes four physical and sixteen virtual temperature sensors, a flow sensor and four PWM controllable fans, along with their speed (in RPM), power, -voltage and current. +voltage and current. Flow sensor pulses are also available. The Farbwerk and Farbwerk 360 expose four temperature sensors. Additionally, sixteen virtual temperature sensors of the Farbwerk 360 are exposed. @@ -64,6 +64,7 @@ Sysfs entries temp[1-20]_input Physical/virtual temperature sensors (in millidegrees Celsius) temp[1-4]_offset Temperature sensor correction offset (in millidegrees Celsius) fan[1-8]_input Pump/fan speed (in RPM) / Flow speed (in dL/h) +fan5_pulses Quadro flow sensor pulses power[1-8]_input Pump/fan power (in micro Watts) in[0-7]_input Pump/fan voltage (in milli Volts) curr[1-8]_input Pump/fan current (in milli Amperes) |