summaryrefslogtreecommitdiff
path: root/Documentation/ABI/testing/sysfs-class-led-trigger-netdev
diff options
context:
space:
mode:
authorChristian Marangi <ansuelsmth@gmail.com>2023-06-21 12:26:53 +0300
committerJakub Kicinski <kuba@kernel.org>2023-06-23 05:51:02 +0300
commit2ffb8d02a9b60d9190a871cb8466cd0721bc0a49 (patch)
tree450ff39b21491e07f0b317848e148aaaed14b083 /Documentation/ABI/testing/sysfs-class-led-trigger-netdev
parent004d25060c78fc31f66da0fa439c544dda1ac9d5 (diff)
downloadlinux-2ffb8d02a9b60d9190a871cb8466cd0721bc0a49.tar.xz
docs: ABI: sysfs-class-led-trigger-netdev: add new modes and entry
Document newly introduced modes and entry for the LED netdev trigger. Add documentation for new modes: - link_10 - link_100 - link_1000 - half_duplex - full_duplex Add documentation for new entry: - hw_control Also add additional info for the interval entry and the tx/rx modes with the special case of hw_control ON. Signed-off-by: Christian Marangi <ansuelsmth@gmail.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Link: https://lore.kernel.org/r/20230621092653.23172-1-ansuelsmth@gmail.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Diffstat (limited to 'Documentation/ABI/testing/sysfs-class-led-trigger-netdev')
-rw-r--r--Documentation/ABI/testing/sysfs-class-led-trigger-netdev89
1 files changed, 89 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-led-trigger-netdev b/Documentation/ABI/testing/sysfs-class-led-trigger-netdev
index 646540950e38..78b62a23b14a 100644
--- a/Documentation/ABI/testing/sysfs-class-led-trigger-netdev
+++ b/Documentation/ABI/testing/sysfs-class-led-trigger-netdev
@@ -13,6 +13,11 @@ Description:
Specifies the duration of the LED blink in milliseconds.
Defaults to 50 ms.
+ With hw_control ON, the interval value MUST be set to the
+ default value and cannot be changed.
+ Trying to set any value in this specific mode will return
+ an EINVAL error.
+
What: /sys/class/leds/<led>/link
Date: Dec 2017
KernelVersion: 4.16
@@ -39,6 +44,9 @@ Description:
If set to 1, the LED will blink for the milliseconds specified
in interval to signal transmission.
+ With hw_control ON, the blink interval is controlled by hardware
+ and won't reflect the value set in interval.
+
What: /sys/class/leds/<led>/rx
Date: Dec 2017
KernelVersion: 4.16
@@ -50,3 +58,84 @@ Description:
If set to 1, the LED will blink for the milliseconds specified
in interval to signal reception.
+
+ With hw_control ON, the blink interval is controlled by hardware
+ and won't reflect the value set in interval.
+
+What: /sys/class/leds/<led>/hw_control
+Date: Jun 2023
+KernelVersion: 6.5
+Contact: linux-leds@vger.kernel.org
+Description:
+ Communicate whether the LED trigger modes are driven by hardware
+ or software fallback is used.
+
+ If 0, the LED is using software fallback to blink.
+
+ If 1, the LED is using hardware control to blink and signal the
+ requested modes.
+
+What: /sys/class/leds/<led>/link_10
+Date: Jun 2023
+KernelVersion: 6.5
+Contact: linux-leds@vger.kernel.org
+Description:
+ Signal the link speed state of 10Mbps of the named network device.
+
+ If set to 0 (default), the LED's normal state is off.
+
+ If set to 1, the LED's normal state reflects the link state
+ speed of 10MBps of the named network device.
+ Setting this value also immediately changes the LED state.
+
+What: /sys/class/leds/<led>/link_100
+Date: Jun 2023
+KernelVersion: 6.5
+Contact: linux-leds@vger.kernel.org
+Description:
+ Signal the link speed state of 100Mbps of the named network device.
+
+ If set to 0 (default), the LED's normal state is off.
+
+ If set to 1, the LED's normal state reflects the link state
+ speed of 100Mbps of the named network device.
+ Setting this value also immediately changes the LED state.
+
+What: /sys/class/leds/<led>/link_1000
+Date: Jun 2023
+KernelVersion: 6.5
+Contact: linux-leds@vger.kernel.org
+Description:
+ Signal the link speed state of 1000Mbps of the named network device.
+
+ If set to 0 (default), the LED's normal state is off.
+
+ If set to 1, the LED's normal state reflects the link state
+ speed of 1000Mbps of the named network device.
+ Setting this value also immediately changes the LED state.
+
+What: /sys/class/leds/<led>/half_duplex
+Date: Jun 2023
+KernelVersion: 6.5
+Contact: linux-leds@vger.kernel.org
+Description:
+ Signal the link half duplex state of the named network device.
+
+ If set to 0 (default), the LED's normal state is off.
+
+ If set to 1, the LED's normal state reflects the link half
+ duplex state of the named network device.
+ Setting this value also immediately changes the LED state.
+
+What: /sys/class/leds/<led>/full_duplex
+Date: Jun 2023
+KernelVersion: 6.5
+Contact: linux-leds@vger.kernel.org
+Description:
+ Signal the link full duplex state of the named network device.
+
+ If set to 0 (default), the LED's normal state is off.
+
+ If set to 1, the LED's normal state reflects the link full
+ duplex state of the named network device.
+ Setting this value also immediately changes the LED state.