diff options
author | Peter Ujfalusi <peter.ujfalusi@ti.com> | 2020-10-29 13:03:35 +0300 |
---|---|---|
committer | Daniel Lezcano <daniel.lezcano@linaro.org> | 2020-11-12 14:30:29 +0300 |
commit | b98467fe96d2415836d154ecfe1cd389bf4147b5 (patch) | |
tree | 147b16f86708bc381d3b6efed0c1f4424c0a1dbb | |
parent | f8394f232b1eab649ce2df5c5f15b0e528c92091 (diff) | |
download | linux-b98467fe96d2415836d154ecfe1cd389bf4147b5.tar.xz |
thermal: ti-soc-thermal: Disable the CPU PM notifier for OMAP4430
It has been observed that on OMAP4430 (ES2.0, ES2.1 and ES2.3) the enabled
notifier causes errors on the DTEMP readout values:
ti-soc-thermal 4a002260.bandgap: in range ADC val: 52
ti-soc-thermal 4a002260.bandgap: in range ADC val: 64
ti-soc-thermal 4a002260.bandgap: in range ADC val: 64
ti-soc-thermal 4a002260.bandgap: out of range ADC val: 0
thermal thermal_zone0: failed to read out thermal zone (-5)
ti-soc-thermal 4a002260.bandgap: out of range ADC val: 0
thermal thermal_zone0: failed to read out thermal zone (-5)
ti-soc-thermal 4a002260.bandgap: out of range ADC val: 4
thermal thermal_zone0: failed to read out thermal zone (-5)
ti-soc-thermal 4a002260.bandgap: in range ADC val: 100
raw 100 translates to 133 Celsius on omap4-sdp, triggering shutdown due to
critical temperature.
When the notifier is disable for OMAP4430 the DTEMP values are stable:
ti-soc-thermal 4a002260.bandgap: in range ADC val: 56
ti-soc-thermal 4a002260.bandgap: in range ADC val: 56
ti-soc-thermal 4a002260.bandgap: in range ADC val: 57
ti-soc-thermal 4a002260.bandgap: in range ADC val: 57
ti-soc-thermal 4a002260.bandgap: in range ADC val: 56
Fixes: 5093402e5b44 ("thermal: ti-soc-thermal: Enable addition power management")
Signed-off-by: Peter Ujfalusi <peter.ujfalusi@ti.com>
Tested-by: Tony Lindgren <tony@atomide.com>
Acked-by: Keerthy <j-keerthy@ti.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201029100335.27665-1-peter.ujfalusi@ti.com
-rw-r--r-- | drivers/thermal/ti-soc-thermal/ti-bandgap.c | 18 |
1 files changed, 16 insertions, 2 deletions
diff --git a/drivers/thermal/ti-soc-thermal/ti-bandgap.c b/drivers/thermal/ti-soc-thermal/ti-bandgap.c index 5e596168ba73..dcac99f327b0 100644 --- a/drivers/thermal/ti-soc-thermal/ti-bandgap.c +++ b/drivers/thermal/ti-soc-thermal/ti-bandgap.c @@ -20,6 +20,7 @@ #include <linux/err.h> #include <linux/types.h> #include <linux/spinlock.h> +#include <linux/sys_soc.h> #include <linux/reboot.h> #include <linux/of_device.h> #include <linux/of_platform.h> @@ -864,6 +865,17 @@ static struct ti_bandgap *ti_bandgap_build(struct platform_device *pdev) return bgp; } +/* + * List of SoCs on which the CPU PM notifier can cause erros on the DTEMP + * readout. + * Enabled notifier on these machines results in erroneous, random values which + * could trigger unexpected thermal shutdown. + */ +static const struct soc_device_attribute soc_no_cpu_notifier[] = { + { .machine = "OMAP4430" }, + { /* sentinel */ }, +}; + /*** Device driver call backs ***/ static @@ -1020,7 +1032,8 @@ int ti_bandgap_probe(struct platform_device *pdev) #ifdef CONFIG_PM_SLEEP bgp->nb.notifier_call = bandgap_omap_cpu_notifier; - cpu_pm_register_notifier(&bgp->nb); + if (!soc_device_match(soc_no_cpu_notifier)) + cpu_pm_register_notifier(&bgp->nb); #endif return 0; @@ -1056,7 +1069,8 @@ int ti_bandgap_remove(struct platform_device *pdev) struct ti_bandgap *bgp = platform_get_drvdata(pdev); int i; - cpu_pm_unregister_notifier(&bgp->nb); + if (!soc_device_match(soc_no_cpu_notifier)) + cpu_pm_unregister_notifier(&bgp->nb); /* Remove sensor interfaces */ for (i = 0; i < bgp->conf->sensor_count; i++) { |