x86/resctrl: Make __mon_event_count() handle sum domains
Legacy resctrl monitor files must provide the sum of event values across
all Sub-NUMA Cluster (SNC) domains that share an L3 cache instance.
There are now two cases:
1) A specific domain is provided in struct rmid_read
This is either a non-SNC system, or the request is to read data
from just one SNC node.
2) Domain pointer is NULL. In this case the cacheinfo field in struct
rmid_read indicates that all SNC nodes that share that L3 cache
instance should have the event read and return the sum of all
values.
Update the CPU sanity check. The existing check that an event is read
from a CPU in the requested domain still applies when reading a single
domain. But when summing across domains a more relaxed check that the
current CPU is in the scope of the L3 cache instance is appropriate
since the MSRs to read events are scoped at L3 cache level.
Signed-off-by: Tony Luck <tony.luck@intel.com>
Signed-off-by: Borislav Petkov (AMD) <bp@alien8.de>
Reviewed-by: Reinette Chatre <reinette.chatre@intel.com>
Tested-by: Babu Moger <babu.moger@amd.com>
Link: https://lore.kernel.org/r/20240628215619.76401-17-tony.luck@intel.com
-rw-r--r-- | arch/x86/kernel/cpu/resctrl/monitor.c | 51 |
1 files changed, 42 insertions, 9 deletions
diff --git a/arch/x86/kernel/cpu/resctrl/monitor.c b/arch/x86/kernel/cpu/resctrl/monitor.c index ca309c93a56b..ca486d00541e 100644 --- a/arch/x86/kernel/cpu/resctrl/monitor.c +++ b/arch/x86/kernel/cpu/resctrl/monitor.c @@ -324,9 +324,6 @@ int resctrl_arch_rmid_read(struct rdt_resource *r, struct rdt_mon_domain *d, resctrl_arch_rmid_read_context_check(); - if (!cpumask_test_cpu(smp_processor_id(), &d->hdr.cpu_mask)) - return -EINVAL; - prmid = logical_rmid_to_physical_rmid(cpu, rmid); ret = __rmid_read_phys(prmid, eventid, &msr_val); if (ret) @@ -592,7 +589,10 @@ static struct mbm_state *get_mbm_state(struct rdt_mon_domain *d, u32 closid, static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) { + int cpu = smp_processor_id(); + struct rdt_mon_domain *d; struct mbm_state *m; + int err, ret; u64 tval = 0; if (rr->first) { @@ -603,14 +603,47 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) return 0; } - rr->err = resctrl_arch_rmid_read(rr->r, rr->d, closid, rmid, rr->evtid, - &tval, rr->arch_mon_ctx); - if (rr->err) - return rr->err; + if (rr->d) { + /* Reading a single domain, must be on a CPU in that domain. */ + if (!cpumask_test_cpu(cpu, &rr->d->hdr.cpu_mask)) + return -EINVAL; + rr->err = resctrl_arch_rmid_read(rr->r, rr->d, closid, rmid, + rr->evtid, &tval, rr->arch_mon_ctx); + if (rr->err) + return rr->err; - rr->val += tval; + rr->val += tval; - return 0; + return 0; + } + + /* Summing domains that share a cache, must be on a CPU for that cache. */ + if (!cpumask_test_cpu(cpu, &rr->ci->shared_cpu_map)) + return -EINVAL; + + /* + * Legacy files must report the sum of an event across all + * domains that share the same L3 cache instance. + * Report success if a read from any domain succeeds, -EINVAL + * (translated to "Unavailable" for user space) if reading from + * all domains fail for any reason. + */ + ret = -EINVAL; + list_for_each_entry(d, &rr->r->mon_domains, hdr.list) { + if (d->ci->id != rr->ci->id) + continue; + err = resctrl_arch_rmid_read(rr->r, d, closid, rmid, + rr->evtid, &tval, rr->arch_mon_ctx); + if (!err) { + rr->val += tval; + ret = 0; + } + } + + if (ret) + rr->err = ret; + + return ret; } /* |