diff options
Diffstat (limited to 'Documentation/powerpc/papr_hcalls.rst')
-rw-r--r-- | Documentation/powerpc/papr_hcalls.rst | 14 |
1 files changed, 14 insertions, 0 deletions
diff --git a/Documentation/powerpc/papr_hcalls.rst b/Documentation/powerpc/papr_hcalls.rst index 48fcf1255a33..648f278eea8f 100644 --- a/Documentation/powerpc/papr_hcalls.rst +++ b/Documentation/powerpc/papr_hcalls.rst @@ -275,6 +275,20 @@ Health Bitmap Flags: Given a DRC Index collect the performance statistics for NVDIMM and copy them to the resultBuffer. +**H_SCM_FLUSH** + +| Input: *drcIndex, continue-token* +| Out: *continue-token* +| Return Value: *H_SUCCESS, H_Parameter, H_P2, H_BUSY* + +Given a DRC Index Flush the data to backend NVDIMM device. + +The hcall returns H_BUSY when the flush takes longer time and the hcall needs +to be issued multiple times in order to be completely serviced. The +*continue-token* from the output to be passed in the argument list of +subsequent hcalls to the hypervisor until the hcall is completely serviced +at which point H_SUCCESS or other error is returned by the hypervisor. + References ========== .. [1] "Power Architecture Platform Reference" |