summaryrefslogtreecommitdiff
path: root/Documentation/powerpc/papr_hcalls.rst
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/powerpc/papr_hcalls.rst')
-rw-r--r--Documentation/powerpc/papr_hcalls.rst14
1 files changed, 14 insertions, 0 deletions
diff --git a/Documentation/powerpc/papr_hcalls.rst b/Documentation/powerpc/papr_hcalls.rst
index 48fcf1255a33..648f278eea8f 100644
--- a/Documentation/powerpc/papr_hcalls.rst
+++ b/Documentation/powerpc/papr_hcalls.rst
@@ -275,6 +275,20 @@ Health Bitmap Flags:
Given a DRC Index collect the performance statistics for NVDIMM and copy them
to the resultBuffer.
+**H_SCM_FLUSH**
+
+| Input: *drcIndex, continue-token*
+| Out: *continue-token*
+| Return Value: *H_SUCCESS, H_Parameter, H_P2, H_BUSY*
+
+Given a DRC Index Flush the data to backend NVDIMM device.
+
+The hcall returns H_BUSY when the flush takes longer time and the hcall needs
+to be issued multiple times in order to be completely serviced. The
+*continue-token* from the output to be passed in the argument list of
+subsequent hcalls to the hypervisor until the hcall is completely serviced
+at which point H_SUCCESS or other error is returned by the hypervisor.
+
References
==========
.. [1] "Power Architecture Platform Reference"