@@ -17,8 +17,9 @@ management with temperature and remote voltage sensing. Various fan control
features are provided, including PWM frequency control, temperature hysteresis,
dual tachometer measurements, and fan health monitoring.
-For dual rotor fan configuration, the MAX31785 exposes the slowest rotor of the
-two in the fan[1-4]_input attributes.
+For dual-rotor configurations the MAX31785A exposes the second rotor tachometer
+readings in attributes fan[5-8]_input. By contrast the MAX31785 only exposes
+the slowest rotor measurement, and does so in the fan[1-4]_input attributes.
Usage Notes
-----------
@@ -31,7 +32,9 @@ Sysfs attributes
fan[1-4]_alarm Fan alarm.
fan[1-4]_fault Fan fault.
-fan[1-4]_input Fan RPM.
+fan[1-8]_input Fan RPM. On the MAX31785A, inputs 5-8 correspond to the
+ second rotor of fans 1-4
+fan[1-4]_target Fan input target
in[1-6]_crit Critical maximum output voltage
in[1-6]_crit_alarm Output voltage critical high alarm
@@ -44,6 +47,12 @@ in[1-6]_max_alarm Output voltage high alarm
in[1-6]_min Minimum output voltage
in[1-6]_min_alarm Output voltage low alarm
+pwm[1-4] Fan target duty cycle (0..255)
+pwm[1-4]_enable 0: Full-speed
+ 1: Manual PWM control
+ 2: Automatic PWM (tach-feedback RPM fan-control)
+ 3: Automatic closed-loop (temp-feedback fan-control)
+
temp[1-11]_crit Critical high temperature
temp[1-11]_crit_alarm Chip temperature critical high alarm
temp[1-11]_input Measured temperature