summaryrefslogtreecommitdiff
path: root/tools/perf
diff options
context:
space:
mode:
authorThomas Richter <tmricht@linux.vnet.ibm.com>2018-03-26 11:25:37 +0300
committerArnaldo Carvalho de Melo <acme@redhat.com>2018-03-27 19:13:39 +0300
commitbc17f949d6feb633e579ee7e7dd58d9200073215 (patch)
tree0ea0161ce4e5fe4e9e5413b8d37e8f713cf8aad5 /tools/perf
parent3fb1a23155e91bd00281425041ec2381e435dcc2 (diff)
downloadlinux-bc17f949d6feb633e579ee7e7dd58d9200073215.tar.xz
perf vendor events s390: Add JSON files for IBM z13
Add CPU measurement counter facility event description files (json files) for IBM z13. Signed-off-by: Thomas Richter <tmricht@linux.vnet.ibm.com> Reviewed-by: Hendrik Brueckner <brueckner@linux.vnet.ibm.com> Cc: Heiko Carstens <heiko.carstens@de.ibm.com> Cc: Martin Schwidefsky <schwidefsky@de.ibm.com> Link: http://lkml.kernel.org/r/20180326082538.2258-4-tmricht@linux.vnet.ibm.com Signed-off-by: Arnaldo Carvalho de Melo <acme@redhat.com>
Diffstat (limited to 'tools/perf')
-rw-r--r--tools/perf/pmu-events/arch/s390/cf_z13/basic.json74
-rw-r--r--tools/perf/pmu-events/arch/s390/cf_z13/crypto.json98
-rw-r--r--tools/perf/pmu-events/arch/s390/cf_z13/extended.json338
-rw-r--r--tools/perf/pmu-events/arch/s390/mapfile.csv1
4 files changed, 511 insertions, 0 deletions
diff --git a/tools/perf/pmu-events/arch/s390/cf_z13/basic.json b/tools/perf/pmu-events/arch/s390/cf_z13/basic.json
new file mode 100644
index 000000000000..8bf16759ca53
--- /dev/null
+++ b/tools/perf/pmu-events/arch/s390/cf_z13/basic.json
@@ -0,0 +1,74 @@
+[
+ {
+ "EventCode": "0",
+ "EventName": "CPU_CYCLES",
+ "BriefDescription": "CPU Cycles",
+ "PublicDescription": "Cycle Count"
+ },
+ {
+ "EventCode": "1",
+ "EventName": "INSTRUCTIONS",
+ "BriefDescription": "Instructions",
+ "PublicDescription": "Instruction Count"
+ },
+ {
+ "EventCode": "2",
+ "EventName": "L1I_DIR_WRITES",
+ "BriefDescription": "L1I Directory Writes",
+ "PublicDescription": "Level-1 I-Cache Directory Write Count"
+ },
+ {
+ "EventCode": "3",
+ "EventName": "L1I_PENALTY_CYCLES",
+ "BriefDescription": "L1I Penalty Cycles",
+ "PublicDescription": "Level-1 I-Cache Penalty Cycle Count"
+ },
+ {
+ "EventCode": "4",
+ "EventName": "L1D_DIR_WRITES",
+ "BriefDescription": "L1D Directory Writes",
+ "PublicDescription": "Level-1 D-Cache Directory Write Count"
+ },
+ {
+ "EventCode": "5",
+ "EventName": "L1D_PENALTY_CYCLES",
+ "BriefDescription": "L1D Penalty Cycles",
+ "PublicDescription": "Level-1 D-Cache Penalty Cycle Count"
+ },
+ {
+ "EventCode": "32",
+ "EventName": "PROBLEM_STATE_CPU_CYCLES",
+ "BriefDescription": "Problem-State CPU Cycles",
+ "PublicDescription": "Problem-State Cycle Count"
+ },
+ {
+ "EventCode": "33",
+ "EventName": "PROBLEM_STATE_INSTRUCTIONS",
+ "BriefDescription": "Problem-State Instructions",
+ "PublicDescription": "Problem-State Instruction Count"
+ },
+ {
+ "EventCode": "34",
+ "EventName": "PROBLEM_STATE_L1I_DIR_WRITES",
+ "BriefDescription": "Problem-State L1I Directory Writes",
+ "PublicDescription": "Problem-State Level-1 I-Cache Directory Write Count"
+ },
+ {
+ "EventCode": "35",
+ "EventName": "PROBLEM_STATE_L1I_PENALTY_CYCLES",
+ "BriefDescription": "Problem-State L1I Penalty Cycles",
+ "PublicDescription": "Problem-State Level-1 I-Cache Penalty Cycle Count"
+ },
+ {
+ "EventCode": "36",
+ "EventName": "PROBLEM_STATE_L1D_DIR_WRITES",
+ "BriefDescription": "Problem-State L1D Directory Writes",
+ "PublicDescription": "Problem-State Level-1 D-Cache Directory Write Count"
+ },
+ {
+ "EventCode": "37",
+ "EventName": "PROBLEM_STATE_L1D_PENALTY_CYCLES",
+ "BriefDescription": "Problem-State L1D Penalty Cycles",
+ "PublicDescription": "Problem-State Level-1 D-Cache Penalty Cycle Count"
+ },
+]
diff --git a/tools/perf/pmu-events/arch/s390/cf_z13/crypto.json b/tools/perf/pmu-events/arch/s390/cf_z13/crypto.json
new file mode 100644
index 000000000000..7e5b72492141
--- /dev/null
+++ b/tools/perf/pmu-events/arch/s390/cf_z13/crypto.json
@@ -0,0 +1,98 @@
+[
+ {
+ "EventCode": "64",
+ "EventName": "PRNG_FUNCTIONS",
+ "BriefDescription": "PRNG Functions",
+ "PublicDescription": "Total number of the PRNG functions issued by the CPU"
+ },
+ {
+ "EventCode": "65",
+ "EventName": "PRNG_CYCLES",
+ "BriefDescription": "PRNG Cycles",
+ "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing PRNG functions issued by the CPU"
+ },
+ {
+ "EventCode": "66",
+ "EventName": "PRNG_BLOCKED_FUNCTIONS",
+ "BriefDescription": "PRNG Blocked Functions",
+ "PublicDescription": "Total number of the PRNG functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU"
+ },
+ {
+ "EventCode": "67",
+ "EventName": "PRNG_BLOCKED_CYCLES",
+ "BriefDescription": "PRNG Blocked Cycles",
+ "PublicDescription": "Total number of CPU cycles blocked for the PRNG functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU"
+ },
+ {
+ "EventCode": "68",
+ "EventName": "SHA_FUNCTIONS",
+ "BriefDescription": "SHA Functions",
+ "PublicDescription": "Total number of SHA functions issued by the CPU"
+ },
+ {
+ "EventCode": "69",
+ "EventName": "SHA_CYCLES",
+ "BriefDescription": "SHA Cycles",
+ "PublicDescription": "Total number of CPU cycles when the SHA coprocessor is busy performing the SHA functions issued by the CPU"
+ },
+ {
+ "EventCode": "70",
+ "EventName": "SHA_BLOCKED_FUNCTIONS",
+ "BriefDescription": "SHA Blocked Functions",
+ "PublicDescription": "Total number of the SHA functions that are issued by the CPU and are blocked because the SHA coprocessor is busy performing a function issued by another CPU"
+ },
+ {
+ "EventCode": "71",
+ "EventName": "SHA_BLOCKED_CYCLES",
+ "BriefDescription": "SHA Bloced Cycles",
+ "PublicDescription": "Total number of CPU cycles blocked for the SHA functions issued by the CPU because the SHA coprocessor is busy performing a function issued by another CPU"
+ },
+ {
+ "EventCode": "72",
+ "EventName": "DEA_FUNCTIONS",
+ "BriefDescription": "DEA Functions",
+ "PublicDescription": "Total number of the DEA functions issued by the CPU"
+ },
+ {
+ "EventCode": "73",
+ "EventName": "DEA_CYCLES",
+ "BriefDescription": "DEA Cycles",
+ "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing the DEA functions issued by the CPU"
+ },
+ {
+ "EventCode": "74",
+ "EventName": "DEA_BLOCKED_FUNCTIONS",
+ "BriefDescription": "DEA Blocked Functions",
+ "PublicDescription": "Total number of the DEA functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU"
+ },
+ {
+ "EventCode": "75",
+ "EventName": "DEA_BLOCKED_CYCLES",
+ "BriefDescription": "DEA Blocked Cycles",
+ "PublicDescription": "Total number of CPU cycles blocked for the DEA functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU"
+ },
+ {
+ "EventCode": "76",
+ "EventName": "AES_FUNCTIONS",
+ "BriefDescription": "AES Functions",
+ "PublicDescription": "Total number of AES functions issued by the CPU"
+ },
+ {
+ "EventCode": "77",
+ "EventName": "AES_CYCLES",
+ "BriefDescription": "AES Cycles",
+ "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing the AES functions issued by the CPU"
+ },
+ {
+ "EventCode": "78",
+ "EventName": "AES_BLOCKED_FUNCTIONS",
+ "BriefDescription": "AES Blocked Functions",
+ "PublicDescription": "Total number of AES functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU"
+ },
+ {
+ "EventCode": "79",
+ "EventName": "AES_BLOCKED_CYCLES",
+ "BriefDescription": "AES Blocked Cycles",
+ "PublicDescription": "Total number of CPU cycles blocked for the AES functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU"
+ },
+]
diff --git a/tools/perf/pmu-events/arch/s390/cf_z13/extended.json b/tools/perf/pmu-events/arch/s390/cf_z13/extended.json
new file mode 100644
index 000000000000..9a002b6967f1
--- /dev/null
+++ b/tools/perf/pmu-events/arch/s390/cf_z13/extended.json
@@ -0,0 +1,338 @@
+[
+ {
+ "EventCode": "128",
+ "EventName": "L1D_RO_EXCL_WRITES",
+ "BriefDescription": "L1D Read-only Exclusive Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache where the line was originally in a Read-Only state in the cache but has been updated to be in the Exclusive state that allows stores to the cache line."
+ },
+ {
+ "EventCode": "129",
+ "EventName": "DTLB1_WRITES",
+ "BriefDescription": "DTLB1 Writes",
+ "PublicDescription": "A translation entry has been written to the Level-1 Data Translation Lookaside Buffer"
+ },
+ {
+ "EventCode": "130",
+ "EventName": "DTLB1_MISSES",
+ "BriefDescription": "DTLB1 Misses",
+ "PublicDescription": "Level-1 Data TLB miss in progress. Incremented by one for every cycle a DTLB1 miss is in progress."
+ },
+ {
+ "EventCode": "131",
+ "EventName": "DTLB1_HPAGE_WRITES",
+ "BriefDescription": "DTLB1 One-Megabyte Page Writes",
+ "PublicDescription": "A translation entry has been written to the Level-1 Data Translation Lookaside Buffer for a one-megabyte page"
+ },
+ {
+ "EventCode": "132",
+ "EventName": "DTLB1_GPAGE_WRITES",
+ "BriefDescription": "DTLB1 Two-Gigabyte Page Writes",
+ "PublicDescription": "Counter:132 Name:DTLB1_GPAGE_WRITES A translation entry has been written to the Level-1 Data Translation Lookaside Buffer for a two-gigabyte page."
+ },
+ {
+ "EventCode": "133",
+ "EventName": "L1D_L2D_SOURCED_WRITES",
+ "BriefDescription": "L1D L2D Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the Level-2 Data cache"
+ },
+ {
+ "EventCode": "134",
+ "EventName": "ITLB1_WRITES",
+ "BriefDescription": "ITLB1 Writes",
+ "PublicDescription": "A translation entry has been written to the Level-1 Instruction Translation Lookaside Buffer"
+ },
+ {
+ "EventCode": "135",
+ "EventName": "ITLB1_MISSES",
+ "BriefDescription": "ITLB1 Misses",
+ "PublicDescription": "Level-1 Instruction TLB miss in progress. Incremented by one for every cycle an ITLB1 miss is in progress"
+ },
+ {
+ "EventCode": "136",
+ "EventName": "L1I_L2I_SOURCED_WRITES",
+ "BriefDescription": "L1I L2I Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the Level-2 Instruction cache"
+ },
+ {
+ "EventCode": "137",
+ "EventName": "TLB2_PTE_WRITES",
+ "BriefDescription": "TLB2 PTE Writes",
+ "PublicDescription": "A translation entry has been written to the Level-2 TLB Page Table Entry arrays"
+ },
+ {
+ "EventCode": "138",
+ "EventName": "TLB2_CRSTE_HPAGE_WRITES",
+ "BriefDescription": "TLB2 CRSTE One-Megabyte Page Writes",
+ "PublicDescription": "A translation entry has been written to the Level-2 TLB Combined Region Segment Table Entry arrays for a one-megabyte large page translation"
+ },
+ {
+ "EventCode": "139",
+ "EventName": "TLB2_CRSTE_WRITES",
+ "BriefDescription": "TLB2 CRSTE Writes",
+ "PublicDescription": "A translation entry has been written to the Level-2 TLB Combined Region Segment Table Entry arrays"
+ },
+ {
+ "EventCode": "140",
+ "EventName": "TX_C_TEND",
+ "BriefDescription": "Completed TEND instructions in constrained TX mode",
+ "PublicDescription": "A TEND instruction has completed in a constrained transactional-execution mode"
+ },
+ {
+ "EventCode": "141",
+ "EventName": "TX_NC_TEND",
+ "BriefDescription": "Completed TEND instructions in non-constrained TX mode",
+ "PublicDescription": "A TEND instruction has completed in a non-constrained transactional-execution mode"
+ },
+ {
+ "EventCode": "143",
+ "EventName": "L1C_TLB1_MISSES",
+ "BriefDescription": "L1C TLB1 Misses",
+ "PublicDescription": "Increments by one for any cycle where a Level-1 cache or Level-1 TLB miss is in progress."
+ },
+ {
+ "EventCode": "144",
+ "EventName": "L1D_ONCHIP_L3_SOURCED_WRITES",
+ "BriefDescription": "L1D On-Chip L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "145",
+ "EventName": "L1D_ONCHIP_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1D On-Chip L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "146",
+ "EventName": "L1D_ONNODE_L4_SOURCED_WRITES",
+ "BriefDescription": "L1D On-Node L4 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Node Level-4 cache"
+ },
+ {
+ "EventCode": "147",
+ "EventName": "L1D_ONNODE_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1D On-Node L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Node Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "148",
+ "EventName": "L1D_ONNODE_L3_SOURCED_WRITES",
+ "BriefDescription": "L1D On-Node L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Node Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "149",
+ "EventName": "L1D_ONDRAWER_L4_SOURCED_WRITES",
+ "BriefDescription": "L1D On-Drawer L4 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-4 cache"
+ },
+ {
+ "EventCode": "150",
+ "EventName": "L1D_ONDRAWER_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1D On-Drawer L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "151",
+ "EventName": "L1D_ONDRAWER_L3_SOURCED_WRITES",
+ "BriefDescription": "L1D On-Drawer L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "152",
+ "EventName": "L1D_OFFDRAWER_SCOL_L4_SOURCED_WRITES",
+ "BriefDescription": "L1D Off-Drawer Same-Column L4 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-4 cache"
+ },
+ {
+ "EventCode": "153",
+ "EventName": "L1D_OFFDRAWER_SCOL_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1D Off-Drawer Same-Column L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "154",
+ "EventName": "L1D_OFFDRAWER_SCOL_L3_SOURCED_WRITES",
+ "BriefDescription": "L1D Off-Drawer Same-Column L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "155",
+ "EventName": "L1D_OFFDRAWER_FCOL_L4_SOURCED_WRITES",
+ "BriefDescription": "L1D Off-Drawer Far-Column L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-4 cache"
+ },
+ {
+ "EventCode": "156",
+ "EventName": "L1D_OFFDRAWER_FCOL_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1D Off-Drawer Far-Column L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "157",
+ "EventName": "L1D_OFFDRAWER_FCOL_L3_SOURCED_WRITES",
+ "BriefDescription": "L1D Off-Drawer Far-Column L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "158",
+ "EventName": "L1D_ONNODE_MEM_SOURCED_WRITES",
+ "BriefDescription": "L1D On-Node Memory Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Node memory"
+ },
+ {
+ "EventCode": "159",
+ "EventName": "L1D_ONDRAWER_MEM_SOURCED_WRITES",
+ "BriefDescription": "L1D On-Drawer Memory Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Drawer memory"
+ },
+ {
+ "EventCode": "160",
+ "EventName": "L1D_OFFDRAWER_MEM_SOURCED_WRITES",
+ "BriefDescription": "L1D Off-Drawer Memory Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Drawer memory"
+ },
+ {
+ "EventCode": "161",
+ "EventName": "L1D_ONCHIP_MEM_SOURCED_WRITES",
+ "BriefDescription": "L1D On-Chip Memory Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Chip memory"
+ },
+ {
+ "EventCode": "162",
+ "EventName": "L1I_ONCHIP_L3_SOURCED_WRITES",
+ "BriefDescription": "L1I On-Chip L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "163",
+ "EventName": "L1I_ONCHIP_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1I On-Chip L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On Chip Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "164",
+ "EventName": "L1I_ONNODE_L4_SOURCED_WRITES",
+ "BriefDescription": "L1I On-Chip L4 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Node Level-4 cache"
+ },
+ {
+ "EventCode": "165",
+ "EventName": "L1I_ONNODE_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1I On-Node L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Node Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "166",
+ "EventName": "L1I_ONNODE_L3_SOURCED_WRITES",
+ "BriefDescription": "L1I On-Node L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Node Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "167",
+ "EventName": "L1I_ONDRAWER_L4_SOURCED_WRITES",
+ "BriefDescription": "L1I On-Drawer L4 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-4 cache"
+ },
+ {
+ "EventCode": "168",
+ "EventName": "L1I_ONDRAWER_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1I On-Drawer L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "169",
+ "EventName": "L1I_ONDRAWER_L3_SOURCED_WRITES",
+ "BriefDescription": "L1I On-Drawer L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "170",
+ "EventName": "L1I_OFFDRAWER_SCOL_L4_SOURCED_WRITES",
+ "BriefDescription": "L1I Off-Drawer Same-Column L4 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-4 cache"
+ },
+ {
+ "EventCode": "171",
+ "EventName": "L1I_OFFDRAWER_SCOL_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1I Off-Drawer Same-Column L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "172",
+ "EventName": "L1I_OFFDRAWER_SCOL_L3_SOURCED_WRITES",
+ "BriefDescription": "L1I Off-Drawer Same-Column L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "173",
+ "EventName": "L1I_OFFDRAWER_FCOL_L4_SOURCED_WRITES",
+ "BriefDescription": "L1I Off-Drawer Far-Column L4 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-4 cache"
+ },
+ {
+ "EventCode": "174",
+ "EventName": "L1I_OFFDRAWER_FCOL_L3_SOURCED_WRITES_IV",
+ "BriefDescription": "L1I Off-Drawer Far-Column L3 Sourced Writes with Intervention",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-3 cache with intervention"
+ },
+ {
+ "EventCode": "175",
+ "EventName": "L1I_OFFDRAWER_FCOL_L3_SOURCED_WRITES",
+ "BriefDescription": "L1I Off-Drawer Far-Column L3 Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-3 cache without intervention"
+ },
+ {
+ "EventCode": "176",
+ "EventName": "L1I_ONNODE_MEM_SOURCED_WRITES",
+ "BriefDescription": "L1I On-Node Memory Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Node memory"
+ },
+ {
+ "EventCode": "177",
+ "EventName": "L1I_ONDRAWER_MEM_SOURCED_WRITES",
+ "BriefDescription": "L1I On-Drawer Memory Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Drawer memory"
+ },
+ {
+ "EventCode": "178",
+ "EventName": "L1I_OFFDRAWER_MEM_SOURCED_WRITES",
+ "BriefDescription": "L1I Off-Drawer Memory Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Drawer memory"
+ },
+ {
+ "EventCode": "179",
+ "EventName": "L1I_ONCHIP_MEM_SOURCED_WRITES",
+ "BriefDescription": "L1I On-Chip Memory Sourced Writes",
+ "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Chip memory"
+ },
+ {
+ "EventCode": "218",
+ "EventName": "TX_NC_TABORT",
+ "BriefDescription": "Aborted transactions in non-constrained TX mode",
+ "PublicDescription": "A transaction abort has occurred in a non-constrained transactional-execution mode"
+ },
+ {
+ "EventCode": "219",
+ "EventName": "TX_C_TABORT_NO_SPECIAL",
+ "BriefDescription": "Aborted transactions in constrained TX mode not using special completion logic",
+ "PublicDescription": "A transaction abort has occurred in a constrained transactional-execution mode and the CPU is not using any special logic to allow the transaction to complete"
+ },
+ {
+ "EventCode": "220",
+ "EventName": "TX_C_TABORT_SPECIAL",
+ "BriefDescription": "Aborted transactions in constrained TX mode using special completion logic",
+ "PublicDescription": "A transaction abort has occurred in a constrained transactional-execution mode and the CPU is using special logic to allow the transaction to complete"
+ },
+ {
+ "EventCode": "448",
+ "EventName": "MT_DIAG_CYCLES_ONE_THR_ACTIVE",
+ "BriefDescription": "Cycle count with one thread active",
+ "PublicDescription": "Cycle count with one thread active"
+ },
+ {
+ "EventCode": "449",
+ "EventName": "MT_DIAG_CYCLES_TWO_THR_ACTIVE",
+ "BriefDescription": "Cycle count with two threads active",
+ "PublicDescription": "Cycle count with two threads active"
+ },
+]
diff --git a/tools/perf/pmu-events/arch/s390/mapfile.csv b/tools/perf/pmu-events/arch/s390/mapfile.csv
index c57f8e75fa23..3cff9c64bb85 100644
--- a/tools/perf/pmu-events/arch/s390/mapfile.csv
+++ b/tools/perf/pmu-events/arch/s390/mapfile.csv
@@ -2,3 +2,4 @@ Family-model,Version,Filename,EventType
209[78],1,cf_z10,core
281[78],1,cf_z196,core
282[78],1,cf_zec12,core
+296[45],1,cf_z13,core