summaryrefslogtreecommitdiff
path: root/scripts/gdb/linux/utils.py
diff options
context:
space:
mode:
authorVadim Pasternak <vadimp@nvidia.com>2023-08-24 16:43:10 +0300
committerDavid S. Miller <davem@davemloft.net>2023-08-25 12:53:37 +0300
commit3fc134a07438055fc93ce1bbacf2702ddd09500c (patch)
treee6892e2516d5dd59d35c2a881591b0b8b79a4231 /scripts/gdb/linux/utils.py
parentd7248f1cc835bd80e936dc5b2d94b149bdd0077d (diff)
downloadlinux-3fc134a07438055fc93ce1bbacf2702ddd09500c.tar.xz
mlxsw: core_hwmon: Adjust module label names based on MTCAP sensor counter
Transceiver module temperature sensors are indexed after ASIC and platform sensors. The current label printing method does not take this into account and simply prints the index of the transceiver module sensor. On new systems that have platform sensors this results in incorrect (shifted) transceiver module labels being printed: $ sensors [...] front panel 002: +37.0°C (crit = +70.0°C, emerg = +75.0°C) front panel 003: +47.0°C (crit = +70.0°C, emerg = +75.0°C) [...] Fix by taking the sensor count into account. After the fix: $ sensors [...] front panel 001: +37.0°C (crit = +70.0°C, emerg = +75.0°C) front panel 002: +47.0°C (crit = +70.0°C, emerg = +75.0°C) [...] Fixes: a53779de6a0e ("mlxsw: core: Add QSFP module temperature label attribute to hwmon") Signed-off-by: Vadim Pasternak <vadimp@nvidia.com> Reviewed-by: Ido Schimmel <idosch@nvidia.com> Signed-off-by: Petr Machata <petrm@nvidia.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'scripts/gdb/linux/utils.py')
0 files changed, 0 insertions, 0 deletions