hwmon: (pmbus/core) Use s64 instead of long for calculations
Using s64 type, instead of long type, for internal calculations and for the sysfs interface. This allows 64-bit values to appear correctly on 32-bit kernels. As wattage is reported in microwatts, monitoring a power supply over 2KW requires this. Although it may seem unlikely to run a 32-bit kernel on such a large machine, enterprise servers often include a BMC, and the BMC might be running a 32-bit kernel. Signed-off-by: Josh Lehan <krellan@google.com> [groeck: Removed Change-Id and other tags, reformatted description] Signed-off-by: Guenter Roeck <linux@roeck-us.net>