ACPI / battery: fix wrong value of capacity_now reported when fully charged
It seems that some batteries (noticed on DELL JYPJ136) assume capacity_now = design_capacity when fully charged. This causes reported capacity to suddenly jump to >full_charge_capacity (and that means capacity reported to userspace is >100% and incorrect) values after 99%. This patch detects capacity_now > full_charge_capacity, notifies userspace (unless it is the known bug where capacity_now == design_capacity) and trims the value to full_charge_capacity. Signed-off-by: Josef Gajdusek <atx@atx.name> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/acpi/battery.c14
1 files changed, 14 insertions, 0 deletions
diff --git a/drivers/acpi/battery.c b/drivers/acpi/battery.c
index bc0b286ff2ba..130f513e08c9 100644
--- a/drivers/acpi/battery.c
+++ b/drivers/acpi/battery.c
@@ -535,6 +535,20 @@ static int acpi_battery_get_state(struct acpi_battery *battery)
" invalid.\n");
}
+ /*
+ * When fully charged, some batteries wrongly report
+ * capacity_now = design_capacity instead of = full_charge_capacity
+ */
+ if (battery->capacity_now > battery->full_charge_capacity
+ && battery->full_charge_capacity != ACPI_BATTERY_VALUE_UNKNOWN) {
+ battery->capacity_now = battery->full_charge_capacity;
+ if (battery->capacity_now != battery->design_capacity)
+ printk_once(KERN_WARNING FW_BUG
+ "battery: reported current charge level (%d) "
+ "is higher than reported maximum charge level (%d).\n",
+ battery->capacity_now, battery->full_charge_capacity);
+ }
+
if (test_bit(ACPI_BATTERY_QUIRK_PERCENTAGE_CAPACITY, &battery->flags)
&& battery->capacity_now >= 0 && battery->capacity_now <= 100)
battery->capacity_now = (battery->capacity_now *