diff options
author | Daniel Lezcano <daniel.lezcano@linaro.org> | 2021-03-14 14:13:31 +0300 |
---|---|---|
committer | Daniel Lezcano <daniel.lezcano@linaro.org> | 2021-03-15 06:47:04 +0300 |
commit | f8d354e821b268c23a6cd548b7154e55c3954496 (patch) | |
tree | ba3ae1ecdfce2756f6f1a05edf93d80fb3595719 /drivers/thermal/devfreq_cooling.c | |
parent | ef37d1f9acb57b7a5993e93ae582ba5f4108919e (diff) | |
download | linux-f8d354e821b268c23a6cd548b7154e55c3954496.tar.xz |
thermal/drivers/devfreq_cooling: Use device name instead of auto-numbering
Currently the naming of a cooling device is just a cooling technique
followed by a number. When there are multiple cooling devices using
the same technique, it is impossible to clearly identify the related
device as this one is just a number.
For instance:
thermal-devfreq-0
thermal-devfreq-1
etc ...
The 'thermal' prefix is redundant with the subsystem namespace. This
patch removes the 'thermal' prefix and changes the number by the device
name. So the naming above becomes:
devfreq-5000000.gpu
devfreq-1d84000.ufshc
etc ...
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://lore.kernel.org/r/20210314111333.16551-3-daniel.lezcano@linaro.org
Diffstat (limited to 'drivers/thermal/devfreq_cooling.c')
-rw-r--r-- | drivers/thermal/devfreq_cooling.c | 25 |
1 files changed, 8 insertions, 17 deletions
diff --git a/drivers/thermal/devfreq_cooling.c b/drivers/thermal/devfreq_cooling.c index fed3121ff2a1..fb250ac16f50 100644 --- a/drivers/thermal/devfreq_cooling.c +++ b/drivers/thermal/devfreq_cooling.c @@ -14,7 +14,6 @@ #include <linux/devfreq_cooling.h> #include <linux/energy_model.h> #include <linux/export.h> -#include <linux/idr.h> #include <linux/slab.h> #include <linux/pm_opp.h> #include <linux/pm_qos.h> @@ -25,11 +24,8 @@ #define HZ_PER_KHZ 1000 #define SCALE_ERROR_MITIGATION 100 -static DEFINE_IDA(devfreq_ida); - /** * struct devfreq_cooling_device - Devfreq cooling device - * @id: unique integer value corresponding to each * devfreq_cooling_device registered. * @cdev: Pointer to associated thermal cooling device. * @devfreq: Pointer to associated devfreq device. @@ -51,7 +47,6 @@ static DEFINE_IDA(devfreq_ida); * @em_pd: Energy Model for the associated Devfreq device */ struct devfreq_cooling_device { - int id; struct thermal_cooling_device *cdev; struct devfreq *devfreq; unsigned long cooling_state; @@ -363,7 +358,7 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, struct thermal_cooling_device *cdev; struct device *dev = df->dev.parent; struct devfreq_cooling_device *dfc; - char dev_name[THERMAL_NAME_LENGTH]; + char *name; int err, num_opps; dfc = kzalloc(sizeof(*dfc), GFP_KERNEL); @@ -407,30 +402,27 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, if (err < 0) goto free_table; - err = ida_simple_get(&devfreq_ida, 0, 0, GFP_KERNEL); - if (err < 0) + cdev = ERR_PTR(-ENOMEM); + name = kasprintf(GFP_KERNEL, "devfreq-%s", dev_name(dev)); + if (!name) goto remove_qos_req; - dfc->id = err; - - snprintf(dev_name, sizeof(dev_name), "thermal-devfreq-%d", dfc->id); - - cdev = thermal_of_cooling_device_register(np, dev_name, dfc, + cdev = thermal_of_cooling_device_register(np, name, dfc, &devfreq_cooling_ops); + kfree(name); + if (IS_ERR(cdev)) { err = PTR_ERR(cdev); dev_err(dev, "Failed to register devfreq cooling device (%d)\n", err); - goto release_ida; + goto remove_qos_req; } dfc->cdev = cdev; return cdev; -release_ida: - ida_simple_remove(&devfreq_ida, dfc->id); remove_qos_req: dev_pm_qos_remove_request(&dfc->req_max_freq); free_table: @@ -527,7 +519,6 @@ void devfreq_cooling_unregister(struct thermal_cooling_device *cdev) dev = dfc->devfreq->dev.parent; thermal_cooling_device_unregister(dfc->cdev); - ida_simple_remove(&devfreq_ida, dfc->id); dev_pm_qos_remove_request(&dfc->req_max_freq); em_dev_unregister_perf_domain(dev); |