summaryrefslogtreecommitdiff
path: root/drivers/power
diff options
context:
space:
mode:
authorMajor Lee <major_lee@wistrom.com>2011-11-16 03:31:23 +0400
committerIngo Molnar <mingo@elte.hu>2011-12-05 20:06:37 +0400
commita7a280493fb63f8e9fbfc8feec5810bf50e1e54f (patch)
tree9b8be8a0da29a64d0a9e990af1f366a63f09d3f4 /drivers/power
parent2cd1c8d4dc7ecca9e9431e2dabe41ae9c7d89e51 (diff)
downloadlinux-a7a280493fb63f8e9fbfc8feec5810bf50e1e54f.tar.xz
x86/mrst: Battery fixes
When DCDC input line over current detecting, PMIC will change charging current automatically. Logging event is enough. Signed-off-by: Major Lee <major_lee@wistron.com> Signed-off-by: Alan Cox <alan@linux.intel.com> Cc: Mathias Nyman <mathias.nyman@linux.intel.com> Cc: Feng Tang <feng.tang@intel.com> Cc: "H. Peter Anvin" <hpa@zytor.com> [fix build] Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Ingo Molnar <mingo@elte.hu>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/intel_mid_battery.c12
1 files changed, 6 insertions, 6 deletions
diff --git a/drivers/power/intel_mid_battery.c b/drivers/power/intel_mid_battery.c
index cffcb7c00b00..01fa671ec97f 100644
--- a/drivers/power/intel_mid_battery.c
+++ b/drivers/power/intel_mid_battery.c
@@ -61,7 +61,8 @@ MODULE_PARM_DESC(debug, "Flag to enable PMIC Battery debug messages.");
#define PMIC_BATT_CHR_SBATDET_MASK (1 << 5)
#define PMIC_BATT_CHR_SDCLMT_MASK (1 << 6)
#define PMIC_BATT_CHR_SUSBOVP_MASK (1 << 7)
-#define PMIC_BATT_CHR_EXCPT_MASK 0xC6
+#define PMIC_BATT_CHR_EXCPT_MASK 0x86
+
#define PMIC_BATT_ADC_ACCCHRG_MASK (1 << 31)
#define PMIC_BATT_ADC_ACCCHRGVAL_MASK 0x7FFFFFFF
@@ -304,11 +305,6 @@ static void pmic_battery_read_status(struct pmic_power_module_info *pbi)
pbi->batt_status = POWER_SUPPLY_STATUS_NOT_CHARGING;
pmic_battery_log_event(BATT_EVENT_BATOVP_EXCPT);
batt_exception = 1;
- } else if (r8 & PMIC_BATT_CHR_SDCLMT_MASK) {
- pbi->batt_health = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
- pbi->batt_status = POWER_SUPPLY_STATUS_NOT_CHARGING;
- pmic_battery_log_event(BATT_EVENT_DCLMT_EXCPT);
- batt_exception = 1;
} else if (r8 & PMIC_BATT_CHR_STEMP_MASK) {
pbi->batt_health = POWER_SUPPLY_HEALTH_OVERHEAT;
pbi->batt_status = POWER_SUPPLY_STATUS_NOT_CHARGING;
@@ -316,6 +312,10 @@ static void pmic_battery_read_status(struct pmic_power_module_info *pbi)
batt_exception = 1;
} else {
pbi->batt_health = POWER_SUPPLY_HEALTH_GOOD;
+ if (r8 & PMIC_BATT_CHR_SDCLMT_MASK) {
+ /* PMIC will change charging current automatically */
+ pmic_battery_log_event(BATT_EVENT_DCLMT_EXCPT);
+ }
}
}