summaryrefslogtreecommitdiff
path: root/drivers/parisc
diff options
context:
space:
mode:
authorThierry Reding <treding@nvidia.com>2014-11-13 16:27:29 +0300
committerThierry Reding <treding@nvidia.com>2014-11-13 18:12:10 +0300
commit183ef2883d060d69d17d63f7c56fbf1a5d65e3f9 (patch)
treeaf87185c07e47a1c0397723922b03d279bcaedad /drivers/parisc
parent976cebc35bed0456a42bf96073a26f251d23b264 (diff)
downloadlinux-183ef2883d060d69d17d63f7c56fbf1a5d65e3f9.tar.xz
drm/tegra: dsi: Do not manage clock on enable/disable
In preparation for supporting command mode panels, don't disable the clock when the output is disabled. The output will be enabled only after the panel has been programmed in command mode, so the clock must always remain on. As a side-effect, pad calibration now only needs to be done at driver probe time, since neither power nor controller state will go away before driver removal. While at it, use a 32-bit variable to store register content because the registers are 32-bit even on 64-bit Tegra. Signed-off-by: Thierry Reding <treding@nvidia.com>
Diffstat (limited to 'drivers/parisc')
0 files changed, 0 insertions, 0 deletions