cpufreq: scmi: Account for malformed DT in scmi_dev_used_by_cpus()
Broadcom STB platforms were early adopters (2017) of the SCMI framework and as a result, not all deployed systems have a Device Tree entry where SCMI protocol 0x13 (PERFORMANCE) is declared as a clock provider, nor are the CPU Device Tree node(s) referencing protocol 0x13 as their clock provider. This was clarified in commit e11c480b6df1 ("dt-bindings: firmware: arm,scmi: Extend bindings for protocol@13") in 2023. For those platforms, we allow the checks done by scmi_dev_used_by_cpus() to continue, and in the event of not having done an early return, we key off the documented compatible string and give them a pass to continue to use scmi-cpufreq. Fixes: 6c9bb8692272 ("cpufreq: scmi: Skip SCMI devices that aren't used by the CPUs") Signed-off-by: Florian Fainelli <florian.fainelli@broadcom.com> Reviewed-by: Sudeep Holla <sudeep.holla@arm.com> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r--drivers/cpufreq/scmi-cpufreq.c10
1 files changed, 10 insertions, 0 deletions
diff --git a/drivers/cpufreq/scmi-cpufreq.c b/drivers/cpufreq/scmi-cpufreq.c
index ef078426bfd5..38c165d526d1 100644
--- a/drivers/cpufreq/scmi-cpufreq.c
+++ b/drivers/cpufreq/scmi-cpufreq.c
@@ -15,6 +15,7 @@
#include <linux/energy_model.h>
#include <linux/export.h>
#include <linux/module.h>
+#include <linux/of.h>
#include <linux/pm_opp.h>
#include <linux/pm_qos.h>
#include <linux/slab.h>
@@ -424,6 +425,15 @@ static bool scmi_dev_used_by_cpus(struct device *scmi_dev)
return true;
}
+ /*
+ * Older Broadcom STB chips had a "clocks" property for CPU node(s)
+ * that did not match the SCMI performance protocol node, if we got
+ * there, it means we had such an older Device Tree, therefore return
+ * true to preserve backwards compatibility.
+ */
+ if (of_machine_is_compatible("brcm,brcmstb"))
+ return true;
+
return false;
}