summaryrefslogtreecommitdiff
path: root/Documentation/input
diff options
context:
space:
mode:
authorWei-Ning Huang <wnhuang@chromium.org>2017-10-12 09:21:43 +0300
committerJiri Kosina <jkosina@suse.cz>2017-12-01 12:01:01 +0300
commit00720277a517e6dcc4773fb413711fe0131ee9bd (patch)
treeef9e7d02143daab51abe1d03fefd41238812fb6a /Documentation/input
parent127e71bd462b87301f5ff1d1fd686515b4a4af9c (diff)
downloadlinux-00720277a517e6dcc4773fb413711fe0131ee9bd.tar.xz
HID: hid-multitouch: support fine-grain orientation reporting
The current hid-multitouch driver only allow the report of two orientations, vertical and horizontal. We use the Azimuth orientation usage 0x3F under the Digitizer usage page to report orientation if the device supports it. Changelog: v1 -> v2: - Fix commit message. - Remove resolution reporting for ABS_MT_ORIENTATION. v2 -> v3: - Fix commit message. v3 -> v4: - Fix ABS_MT_ORIENTATION ABS param range. - Don't set ABS_MT_ORIENTATION in ABS_DG_HEIGHT when it is already set by ABS_DG_AZIMUTH. v4 -> v5: - Improve multi-touch-protocol.rst documentation. Signed-off-by: Wei-Ning Huang <wnhuang@chromium.org> Signed-off-by: Wei-Ning Huang <wnhuang@google.com> Reviewed-by: Dmitry Torokhov <dtor@chromium.org> Reviewed-by: Henrik Rydberg <rydberg@bitmath.org> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Diffstat (limited to 'Documentation/input')
-rw-r--r--Documentation/input/multi-touch-protocol.rst9
1 files changed, 5 insertions, 4 deletions
diff --git a/Documentation/input/multi-touch-protocol.rst b/Documentation/input/multi-touch-protocol.rst
index 8035868c56bc..b51751a0cd5d 100644
--- a/Documentation/input/multi-touch-protocol.rst
+++ b/Documentation/input/multi-touch-protocol.rst
@@ -269,10 +269,11 @@ ABS_MT_ORIENTATION
The orientation of the touching ellipse. The value should describe a signed
quarter of a revolution clockwise around the touch center. The signed value
range is arbitrary, but zero should be returned for an ellipse aligned with
- the Y axis of the surface, a negative value when the ellipse is turned to
- the left, and a positive value when the ellipse is turned to the
- right. When completely aligned with the X axis, the range max should be
- returned.
+ the Y axis (north) of the surface, a negative value when the ellipse is
+ turned to the left, and a positive value when the ellipse is turned to the
+ right. When aligned with the X axis in the positive direction, the range
+ max should be returned; when aligned with the X axis in the negative
+ direction, the range -max should be returned.
Touch ellipsis are symmetrical by default. For devices capable of true 360
degree orientation, the reported orientation must exceed the range max to