summaryrefslogtreecommitdiff
path: root/drivers/net/wireless/rt2x00/rt2800lib.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/wireless/rt2x00/rt2800lib.c')
-rw-r--r--drivers/net/wireless/rt2x00/rt2800lib.c99
1 files changed, 99 insertions, 0 deletions
diff --git a/drivers/net/wireless/rt2x00/rt2800lib.c b/drivers/net/wireless/rt2x00/rt2800lib.c
index 19534f272d76..4ecacea677ac 100644
--- a/drivers/net/wireless/rt2x00/rt2800lib.c
+++ b/drivers/net/wireless/rt2x00/rt2800lib.c
@@ -1169,6 +1169,102 @@ void rt2800_config_intf(struct rt2x00_dev *rt2x00dev, struct rt2x00_intf *intf,
}
EXPORT_SYMBOL_GPL(rt2800_config_intf);
+static void rt2800_config_ht_opmode(struct rt2x00_dev *rt2x00dev,
+ struct rt2x00lib_erp *erp)
+{
+ bool any_sta_nongf = !!(erp->ht_opmode &
+ IEEE80211_HT_OP_MODE_NON_GF_STA_PRSNT);
+ u8 protection = erp->ht_opmode & IEEE80211_HT_OP_MODE_PROTECTION;
+ u8 mm20_mode, mm40_mode, gf20_mode, gf40_mode;
+ u16 mm20_rate, mm40_rate, gf20_rate, gf40_rate;
+ u32 reg;
+
+ /* default protection rate for HT20: OFDM 24M */
+ mm20_rate = gf20_rate = 0x4004;
+
+ /* default protection rate for HT40: duplicate OFDM 24M */
+ mm40_rate = gf40_rate = 0x4084;
+
+ switch (protection) {
+ case IEEE80211_HT_OP_MODE_PROTECTION_NONE:
+ /*
+ * All STAs in this BSS are HT20/40 but there might be
+ * STAs not supporting greenfield mode.
+ * => Disable protection for HT transmissions.
+ */
+ mm20_mode = mm40_mode = gf20_mode = gf40_mode = 0;
+
+ break;
+ case IEEE80211_HT_OP_MODE_PROTECTION_20MHZ:
+ /*
+ * All STAs in this BSS are HT20 or HT20/40 but there
+ * might be STAs not supporting greenfield mode.
+ * => Protect all HT40 transmissions.
+ */
+ mm20_mode = gf20_mode = 0;
+ mm40_mode = gf40_mode = 2;
+
+ break;
+ case IEEE80211_HT_OP_MODE_PROTECTION_NONMEMBER:
+ /*
+ * Nonmember protection:
+ * According to 802.11n we _should_ protect all
+ * HT transmissions (but we don't have to).
+ *
+ * But if cts_protection is enabled we _shall_ protect
+ * all HT transmissions using a CCK rate.
+ *
+ * And if any station is non GF we _shall_ protect
+ * GF transmissions.
+ *
+ * We decide to protect everything
+ * -> fall through to mixed mode.
+ */
+ case IEEE80211_HT_OP_MODE_PROTECTION_NONHT_MIXED:
+ /*
+ * Legacy STAs are present
+ * => Protect all HT transmissions.
+ */
+ mm20_mode = mm40_mode = gf20_mode = gf40_mode = 2;
+
+ /*
+ * If erp protection is needed we have to protect HT
+ * transmissions with CCK 11M long preamble.
+ */
+ if (erp->cts_protection) {
+ /* don't duplicate RTS/CTS in CCK mode */
+ mm20_rate = mm40_rate = 0x0003;
+ gf20_rate = gf40_rate = 0x0003;
+ }
+ break;
+ };
+
+ /* check for STAs not supporting greenfield mode */
+ if (any_sta_nongf)
+ gf20_mode = gf40_mode = 2;
+
+ /* Update HT protection config */
+ rt2800_register_read(rt2x00dev, MM20_PROT_CFG, &reg);
+ rt2x00_set_field32(&reg, MM20_PROT_CFG_PROTECT_RATE, mm20_rate);
+ rt2x00_set_field32(&reg, MM20_PROT_CFG_PROTECT_CTRL, mm20_mode);
+ rt2800_register_write(rt2x00dev, MM20_PROT_CFG, reg);
+
+ rt2800_register_read(rt2x00dev, MM40_PROT_CFG, &reg);
+ rt2x00_set_field32(&reg, MM40_PROT_CFG_PROTECT_RATE, mm40_rate);
+ rt2x00_set_field32(&reg, MM40_PROT_CFG_PROTECT_CTRL, mm40_mode);
+ rt2800_register_write(rt2x00dev, MM40_PROT_CFG, reg);
+
+ rt2800_register_read(rt2x00dev, GF20_PROT_CFG, &reg);
+ rt2x00_set_field32(&reg, GF20_PROT_CFG_PROTECT_RATE, gf20_rate);
+ rt2x00_set_field32(&reg, GF20_PROT_CFG_PROTECT_CTRL, gf20_mode);
+ rt2800_register_write(rt2x00dev, GF20_PROT_CFG, reg);
+
+ rt2800_register_read(rt2x00dev, GF40_PROT_CFG, &reg);
+ rt2x00_set_field32(&reg, GF40_PROT_CFG_PROTECT_RATE, gf40_rate);
+ rt2x00_set_field32(&reg, GF40_PROT_CFG_PROTECT_CTRL, gf40_mode);
+ rt2800_register_write(rt2x00dev, GF40_PROT_CFG, reg);
+}
+
void rt2800_config_erp(struct rt2x00_dev *rt2x00dev, struct rt2x00lib_erp *erp,
u32 changed)
{
@@ -1213,6 +1309,9 @@ void rt2800_config_erp(struct rt2x00_dev *rt2x00dev, struct rt2x00lib_erp *erp,
erp->beacon_int * 16);
rt2800_register_write(rt2x00dev, BCN_TIME_CFG, reg);
}
+
+ if (changed & BSS_CHANGED_HT)
+ rt2800_config_ht_opmode(rt2x00dev, erp);
}
EXPORT_SYMBOL_GPL(rt2800_config_erp);