diff options
author | Benson Leung <bleung@chromium.org> | 2021-01-29 09:14:04 +0300 |
---|---|---|
committer | Benson Leung <bleung@chromium.org> | 2021-02-02 10:49:54 +0300 |
commit | 3b3dd1f0dbfe92781c60f36ea5c22b26360f9909 (patch) | |
tree | 39677549f67a6d2ef9bda2c6e040fa12690456fe /drivers/platform/chrome | |
parent | 14336151fdf1046853fea7c68aa116b8f47bb2a4 (diff) | |
download | linux-3b3dd1f0dbfe92781c60f36ea5c22b26360f9909.tar.xz |
platform/chrome: cros_ec_typec: Report SOP' PD revision from status
cros_typec_handle_sop_prime_disc now takes the PD revision provided
by the EC_CMD_TYPEC_STATUS command response for the SOP'.
Attach the properly formatted pd_revision to the cable desc before
registering the cable.
Signed-off-by: Benson Leung <bleung@chromium.org>
Acked-by: Heikki Krogerus <heikki.krogerus@linux.intel.com>
Acked-by: Enric Balletbo i Serra <enric.balletbo@collabora.com>
Reviewed-by: Prashant Malani <pmalani@chromium.org>
Link: https://lore.kernel.org/r/20210129061406.2680146-5-bleung@chromium.org
Signed-off-by: Benson Leung <bleung@chromium.org>
Diffstat (limited to 'drivers/platform/chrome')
-rw-r--r-- | drivers/platform/chrome/cros_ec_typec.c | 9 |
1 files changed, 7 insertions, 2 deletions
diff --git a/drivers/platform/chrome/cros_ec_typec.c b/drivers/platform/chrome/cros_ec_typec.c index e724a5eaef1c..30600e9454e1 100644 --- a/drivers/platform/chrome/cros_ec_typec.c +++ b/drivers/platform/chrome/cros_ec_typec.c @@ -748,7 +748,7 @@ static void cros_typec_parse_pd_identity(struct usb_pd_identity *id, id->vdo[i - 3] = disc->discovery_vdo[i]; } -static int cros_typec_handle_sop_prime_disc(struct cros_typec_data *typec, int port_num) +static int cros_typec_handle_sop_prime_disc(struct cros_typec_data *typec, int port_num, u16 pd_revision) { struct cros_typec_port *port = typec->ports[port_num]; struct ec_response_typec_discovery *disc = port->disc_data; @@ -794,6 +794,7 @@ static int cros_typec_handle_sop_prime_disc(struct cros_typec_data *typec, int p } c_desc.identity = &port->c_identity; + c_desc.pd_revision = pd_revision; port->cable = typec_register_cable(port->port, &c_desc); if (IS_ERR(port->cable)) { @@ -893,7 +894,11 @@ static void cros_typec_handle_status(struct cros_typec_data *typec, int port_num if (resp.events & PD_STATUS_EVENT_SOP_PRIME_DISC_DONE && !typec->ports[port_num]->sop_prime_disc_done) { - ret = cros_typec_handle_sop_prime_disc(typec, port_num); + u16 sop_prime_revision; + + /* Convert BCD to the format preferred by the TypeC framework */ + sop_prime_revision = (le16_to_cpu(resp.sop_prime_revision) & 0xff00) >> 4; + ret = cros_typec_handle_sop_prime_disc(typec, port_num, sop_prime_revision); if (ret < 0) dev_err(typec->dev, "Couldn't parse SOP' Disc data, port: %d\n", port_num); else |