summaryrefslogtreecommitdiff
path: root/drivers/net
diff options
context:
space:
mode:
authorManish Chopra <manishc@marvell.com>2019-12-11 20:59:55 +0300
committerJakub Kicinski <jakub.kicinski@netronome.com>2019-12-14 23:59:16 +0300
commit7113f796bbbced2470cd6d7379d50d7a7a78bf34 (patch)
treee50adb6c869661ccfba2241543817b17d6c1a90a /drivers/net
parented56dd8f60cf3d56ca1416288b09eec27bdd5413 (diff)
downloadlinux-7113f796bbbced2470cd6d7379d50d7a7a78bf34.tar.xz
bnx2x: Do not handle requests from VFs after parity
Parity error from the hardware will cause PF to lose the state of their VFs due to PF's internal reload and hardware reset following the parity error. Restrict any configuration request from the VFs after the parity as it could cause unexpected hardware behavior, only way for VFs to recover would be to trigger FLR on VFs and reload them. Signed-off-by: Manish Chopra <manishc@marvell.com> Signed-off-by: Ariel Elior <aelior@marvell.com> Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
Diffstat (limited to 'drivers/net')
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c12
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h1
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c12
3 files changed, 23 insertions, 2 deletions
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
index 192ff8d5da32..cff64e43bdd8 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
@@ -9976,10 +9976,18 @@ static void bnx2x_recovery_failed(struct bnx2x *bp)
*/
static void bnx2x_parity_recover(struct bnx2x *bp)
{
- bool global = false;
u32 error_recovered, error_unrecovered;
- bool is_parity;
+ bool is_parity, global = false;
+#ifdef CONFIG_BNX2X_SRIOV
+ int vf_idx;
+
+ for (vf_idx = 0; vf_idx < bp->requested_nr_virtfn; vf_idx++) {
+ struct bnx2x_virtf *vf = BP_VF(bp, vf_idx);
+ if (vf)
+ vf->state = VF_LOST;
+ }
+#endif
DP(NETIF_MSG_HW, "Handling parity\n");
while (1) {
switch (bp->recovery_state) {
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
index b6ebd92ec565..3a716c015415 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.h
@@ -139,6 +139,7 @@ struct bnx2x_virtf {
#define VF_ACQUIRED 1 /* VF acquired, but not initialized */
#define VF_ENABLED 2 /* VF Enabled */
#define VF_RESET 3 /* VF FLR'd, pending cleanup */
+#define VF_LOST 4 /* Recovery while VFs are loaded */
bool flr_clnup_stage; /* true during flr cleanup */
bool malicious; /* true if FW indicated so, until FLR */
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
index 0752b7fa4d9c..ea0e9394f898 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_vfpf.c
@@ -2107,6 +2107,18 @@ static void bnx2x_vf_mbx_request(struct bnx2x *bp, struct bnx2x_virtf *vf,
{
int i;
+ if (vf->state == VF_LOST) {
+ /* Just ack the FW and return if VFs are lost
+ * in case of parity error. VFs are supposed to be timedout
+ * on waiting for PF response.
+ */
+ DP(BNX2X_MSG_IOV,
+ "VF 0x%x lost, not handling the request\n", vf->abs_vfid);
+
+ storm_memset_vf_mbx_ack(bp, vf->abs_vfid);
+ return;
+ }
+
/* check if tlv type is known */
if (bnx2x_tlv_supported(mbx->first_tlv.tl.type)) {