summaryrefslogtreecommitdiff
path: root/drivers/cpufreq
diff options
context:
space:
mode:
authorRafael J. Wysocki <rafael.j.wysocki@intel.com>2018-01-18 04:52:42 +0300
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>2018-01-18 04:52:42 +0300
commitf06970f4b03dffeb9831a8ad605db3c85a55aca1 (patch)
treea4477a4878350d63e3399e7f0d57d64e26065f09 /drivers/cpufreq
parent343a8d17fa8d6dd97f408e8fedbcef12073f3774 (diff)
parentac89c400ebb146604e718b3fa168c15592e73a8c (diff)
downloadlinux-f06970f4b03dffeb9831a8ad605db3c85a55aca1.tar.xz
Merge branch 'pm-cpufreq-thermal' into pm-cpufreq
* pm-cpufreq-thermal: cpu_cooling: Remove static-power related documentation cpu_cooling: Drop static-power related stuff cpu_cooling: Keep only one of_cpufreq*cooling_register() helper cpu_cooling: Remove unused cpufreq_power_cooling_register() cpu_cooling: Make of_cpufreq_power_cooling_register() parse DT
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r--drivers/cpufreq/arm_big_little.c23
-rw-r--r--drivers/cpufreq/cpufreq-dt.c27
-rw-r--r--drivers/cpufreq/mediatek-cpufreq.c22
-rw-r--r--drivers/cpufreq/qoriq-cpufreq.c14
4 files changed, 4 insertions, 82 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c
index 65ec5f01aa8d..c56b57dcfda5 100644
--- a/drivers/cpufreq/arm_big_little.c
+++ b/drivers/cpufreq/arm_big_little.c
@@ -526,34 +526,13 @@ static int bL_cpufreq_exit(struct cpufreq_policy *policy)
static void bL_cpufreq_ready(struct cpufreq_policy *policy)
{
- struct device *cpu_dev = get_cpu_device(policy->cpu);
int cur_cluster = cpu_to_cluster(policy->cpu);
- struct device_node *np;
/* Do not register a cpu_cooling device if we are in IKS mode */
if (cur_cluster >= MAX_CLUSTERS)
return;
- np = of_node_get(cpu_dev->of_node);
- if (WARN_ON(!np))
- return;
-
- if (of_find_property(np, "#cooling-cells", NULL)) {
- u32 power_coefficient = 0;
-
- of_property_read_u32(np, "dynamic-power-coefficient",
- &power_coefficient);
-
- cdev[cur_cluster] = of_cpufreq_power_cooling_register(np,
- policy, power_coefficient, NULL);
- if (IS_ERR(cdev[cur_cluster])) {
- dev_err(cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(cdev[cur_cluster]));
- cdev[cur_cluster] = NULL;
- }
- }
- of_node_put(np);
+ cdev[cur_cluster] = of_cpufreq_cooling_register(policy);
}
static struct cpufreq_driver bL_cpufreq_driver = {
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index 545946ad0752..de3d104c25d7 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -319,33 +319,8 @@ static int cpufreq_exit(struct cpufreq_policy *policy)
static void cpufreq_ready(struct cpufreq_policy *policy)
{
struct private_data *priv = policy->driver_data;
- struct device_node *np = of_node_get(priv->cpu_dev->of_node);
- if (WARN_ON(!np))
- return;
-
- /*
- * For now, just loading the cooling device;
- * thermal DT code takes care of matching them.
- */
- if (of_find_property(np, "#cooling-cells", NULL)) {
- u32 power_coefficient = 0;
-
- of_property_read_u32(np, "dynamic-power-coefficient",
- &power_coefficient);
-
- priv->cdev = of_cpufreq_power_cooling_register(np,
- policy, power_coefficient, NULL);
- if (IS_ERR(priv->cdev)) {
- dev_err(priv->cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(priv->cdev));
-
- priv->cdev = NULL;
- }
- }
-
- of_node_put(np);
+ priv->cdev = of_cpufreq_cooling_register(policy);
}
static struct cpufreq_driver dt_cpufreq_driver = {
diff --git a/drivers/cpufreq/mediatek-cpufreq.c b/drivers/cpufreq/mediatek-cpufreq.c
index b783919f063d..8c04dddd3c28 100644
--- a/drivers/cpufreq/mediatek-cpufreq.c
+++ b/drivers/cpufreq/mediatek-cpufreq.c
@@ -310,28 +310,8 @@ static int mtk_cpufreq_set_target(struct cpufreq_policy *policy,
static void mtk_cpufreq_ready(struct cpufreq_policy *policy)
{
struct mtk_cpu_dvfs_info *info = policy->driver_data;
- struct device_node *np = of_node_get(info->cpu_dev->of_node);
- u32 capacitance = 0;
- if (WARN_ON(!np))
- return;
-
- if (of_find_property(np, "#cooling-cells", NULL)) {
- of_property_read_u32(np, DYNAMIC_POWER, &capacitance);
-
- info->cdev = of_cpufreq_power_cooling_register(np,
- policy, capacitance, NULL);
-
- if (IS_ERR(info->cdev)) {
- dev_err(info->cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(info->cdev));
-
- info->cdev = NULL;
- }
- }
-
- of_node_put(np);
+ info->cdev = of_cpufreq_cooling_register(policy);
}
static int mtk_cpu_dvfs_info_init(struct mtk_cpu_dvfs_info *info, int cpu)
diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c
index 4ada55b8856e..0562761a3dec 100644
--- a/drivers/cpufreq/qoriq-cpufreq.c
+++ b/drivers/cpufreq/qoriq-cpufreq.c
@@ -275,20 +275,8 @@ static int qoriq_cpufreq_target(struct cpufreq_policy *policy,
static void qoriq_cpufreq_ready(struct cpufreq_policy *policy)
{
struct cpu_data *cpud = policy->driver_data;
- struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
- if (of_find_property(np, "#cooling-cells", NULL)) {
- cpud->cdev = of_cpufreq_cooling_register(np, policy);
-
- if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) {
- pr_err("cpu%d is not running as cooling device: %ld\n",
- policy->cpu, PTR_ERR(cpud->cdev));
-
- cpud->cdev = NULL;
- }
- }
-
- of_node_put(np);
+ cpud->cdev = of_cpufreq_cooling_register(policy);
}
static struct cpufreq_driver qoriq_cpufreq_driver = {