diff options
author | Woods, Brian <Brian.Woods@amd.com> | 2018-11-06 23:08:16 +0300 |
---|---|---|
committer | Borislav Petkov <bp@suse.de> | 2018-11-07 23:28:29 +0300 |
commit | 556e4c62baffa71e2045a298379db7e57dd47f3d (patch) | |
tree | 15a43bd981ad397cb80d9a39187a74f97001d001 /arch/x86/kernel/amd_nb.c | |
parent | dedf7dce4cec5c0abe69f4fa6938d5100398220b (diff) | |
download | linux-556e4c62baffa71e2045a298379db7e57dd47f3d.tar.xz |
x86/amd_nb: Add support for newer PCI topologies
Add support for new processors which have multiple PCI root complexes
per data fabric/system management network interface. If there are (N)
multiple PCI roots per DF/SMN interface, then the PCI roots are
redundant (as far as SMN/DF access goes). For each DF/SMN interface:
map to the first available PCI root and skip the next N-1 PCI roots so
the following DF/SMN interface get mapped to a correct PCI root.
Ex:
DF/SMN 0 -> 60
40
20
00
DF/SMN 1 -> e0
c0
a0
80
Signed-off-by: Brian Woods <brian.woods@amd.com>
Signed-off-by: Borislav Petkov <bp@suse.de>
CC: Bjorn Helgaas <bhelgaas@google.com>
CC: Clemens Ladisch <clemens@ladisch.de>
CC: Guenter Roeck <linux@roeck-us.net>
CC: "H. Peter Anvin" <hpa@zytor.com>
CC: Ingo Molnar <mingo@redhat.com>
CC: Jean Delvare <jdelvare@suse.com>
CC: Jia Zhang <qianyue.zj@alibaba-inc.com>
CC: <linux-hwmon@vger.kernel.org>
CC: <linux-pci@vger.kernel.org>
CC: Pu Wen <puwen@hygon.cn>
CC: Thomas Gleixner <tglx@linutronix.de>
CC: x86-ml <x86@kernel.org>
Link: http://lkml.kernel.org/r/20181106200754.60722-3-brian.woods@amd.com
Diffstat (limited to 'arch/x86/kernel/amd_nb.c')
-rw-r--r-- | arch/x86/kernel/amd_nb.c | 44 |
1 files changed, 38 insertions, 6 deletions
diff --git a/arch/x86/kernel/amd_nb.c b/arch/x86/kernel/amd_nb.c index 19d489ee2b1e..cc34266e3c62 100644 --- a/arch/x86/kernel/amd_nb.c +++ b/arch/x86/kernel/amd_nb.c @@ -213,7 +213,10 @@ int amd_cache_northbridges(void) const struct pci_device_id *root_ids = amd_root_ids; struct pci_dev *root, *misc, *link; struct amd_northbridge *nb; - u16 i = 0; + u16 roots_per_misc = 0; + u16 misc_count = 0; + u16 root_count = 0; + u16 i, j; if (amd_northbridges.num) return 0; @@ -226,26 +229,55 @@ int amd_cache_northbridges(void) misc = NULL; while ((misc = next_northbridge(misc, misc_ids)) != NULL) - i++; + misc_count++; - if (!i) + if (!misc_count) return -ENODEV; - nb = kcalloc(i, sizeof(struct amd_northbridge), GFP_KERNEL); + root = NULL; + while ((root = next_northbridge(root, root_ids)) != NULL) + root_count++; + + if (root_count) { + roots_per_misc = root_count / misc_count; + + /* + * There should be _exactly_ N roots for each DF/SMN + * interface. + */ + if (!roots_per_misc || (root_count % roots_per_misc)) { + pr_info("Unsupported AMD DF/PCI configuration found\n"); + return -ENODEV; + } + } + + nb = kcalloc(misc_count, sizeof(struct amd_northbridge), GFP_KERNEL); if (!nb) return -ENOMEM; amd_northbridges.nb = nb; - amd_northbridges.num = i; + amd_northbridges.num = misc_count; link = misc = root = NULL; - for (i = 0; i != amd_northbridges.num; i++) { + for (i = 0; i < amd_northbridges.num; i++) { node_to_amd_nb(i)->root = root = next_northbridge(root, root_ids); node_to_amd_nb(i)->misc = misc = next_northbridge(misc, misc_ids); node_to_amd_nb(i)->link = link = next_northbridge(link, link_ids); + + /* + * If there are more PCI root devices than data fabric/ + * system management network interfaces, then the (N) + * PCI roots per DF/SMN interface are functionally the + * same (for DF/SMN access) and N-1 are redundant. N-1 + * PCI roots should be skipped per DF/SMN interface so + * the following DF/SMN interfaces get mapped to + * correct PCI roots. + */ + for (j = 1; j < roots_per_misc; j++) + root = next_northbridge(root, root_ids); } if (amd_gart_present()) |