summaryrefslogtreecommitdiff
path: root/arch/riscv
diff options
context:
space:
mode:
authorPalmer Dabbelt <palmerdabbelt@google.com>2020-09-14 19:56:30 +0300
committerPalmer Dabbelt <palmerdabbelt@google.com>2020-09-19 23:21:11 +0300
commitd5be89a8d118a8e8d09cd74a921a808f17fbdd09 (patch)
tree23ca84b9c2f1ae9f5f1ac483bf72c60e9934786b /arch/riscv
parentf025d9d9934b84cd03b7796072d10686029c408e (diff)
downloadlinux-d5be89a8d118a8e8d09cd74a921a808f17fbdd09.tar.xz
RISC-V: Resurrect the MMIO timer implementation for M-mode systems
The K210 doesn't implement rdtime in M-mode, and since that's where Linux runs in the NOMMU systems that means we can't use rdtime. The K210 is the only system that anyone is currently running NOMMU or M-mode on, so here we're just inlining the timer read directly. This also adds the CLINT driver as an !MMU dependency, as it's currently the only timer driver availiable for these systems and without it we get a build failure for some configurations. Tested-by: Damien Le Moal <damien.lemoal@wdc.com> Signed-off-by: Palmer Dabbelt <palmerdabbelt@google.com>
Diffstat (limited to 'arch/riscv')
-rw-r--r--arch/riscv/Kconfig1
-rw-r--r--arch/riscv/include/asm/clint.h26
-rw-r--r--arch/riscv/include/asm/timex.h27
3 files changed, 54 insertions, 0 deletions
diff --git a/arch/riscv/Kconfig b/arch/riscv/Kconfig
index df18372861d8..7766e1289468 100644
--- a/arch/riscv/Kconfig
+++ b/arch/riscv/Kconfig
@@ -32,6 +32,7 @@ config RISCV
select ARCH_WANT_FRAME_POINTERS
select ARCH_WANT_HUGE_PMD_SHARE if 64BIT
select CLONE_BACKWARDS
+ select CLINT_TIMER if !MMU
select COMMON_CLK
select EDAC_SUPPORT
select GENERIC_ARCH_TOPOLOGY if SMP
diff --git a/arch/riscv/include/asm/clint.h b/arch/riscv/include/asm/clint.h
new file mode 100644
index 000000000000..0789fd37b40a
--- /dev/null
+++ b/arch/riscv/include/asm/clint.h
@@ -0,0 +1,26 @@
+/* SPDX-License-Identifier: GPL-2.0-only */
+/*
+ * Copyright (C) 2020 Google, Inc
+ */
+
+#ifndef _ASM_RISCV_CLINT_H
+#define _ASM_RISCV_CLINT_H
+
+#include <linux/types.h>
+#include <asm/mmio.h>
+
+#ifdef CONFIG_RISCV_M_MODE
+/*
+ * This lives in the CLINT driver, but is accessed directly by timex.h to avoid
+ * any overhead when accessing the MMIO timer.
+ *
+ * The ISA defines mtime as a 64-bit memory-mapped register that increments at
+ * a constant frequency, but it doesn't define some other constraints we depend
+ * on (most notably ordering constraints, but also some simpler stuff like the
+ * memory layout). Thus, this is called "clint_time_val" instead of something
+ * like "riscv_mtime", to signify that these non-ISA assumptions must hold.
+ */
+extern u64 __iomem *clint_time_val;
+#endif
+
+#endif
diff --git a/arch/riscv/include/asm/timex.h b/arch/riscv/include/asm/timex.h
index a3fb85d505d4..7f659dda0032 100644
--- a/arch/riscv/include/asm/timex.h
+++ b/arch/riscv/include/asm/timex.h
@@ -10,6 +10,31 @@
typedef unsigned long cycles_t;
+#ifdef CONFIG_RISCV_M_MODE
+
+#include <asm/clint.h>
+
+#ifdef CONFIG_64BIT
+static inline cycles_t get_cycles(void)
+{
+ return readq_relaxed(clint_time_val);
+}
+#else /* !CONFIG_64BIT */
+static inline u32 get_cycles(void)
+{
+ return readl_relaxed(((u32 *)clint_time_val));
+}
+#define get_cycles get_cycles
+
+static inline u32 get_cycles_hi(void)
+{
+ return readl_relaxed(((u32 *)clint_time_val) + 1);
+}
+#define get_cycles_hi get_cycles_hi
+#endif /* CONFIG_64BIT */
+
+#else /* CONFIG_RISCV_M_MODE */
+
static inline cycles_t get_cycles(void)
{
return csr_read(CSR_TIME);
@@ -41,6 +66,8 @@ static inline u64 get_cycles64(void)
}
#endif /* CONFIG_64BIT */
+#endif /* !CONFIG_RISCV_M_MODE */
+
#define ARCH_HAS_READ_CURRENT_TIMER
static inline int read_current_timer(unsigned long *timer_val)
{