summaryrefslogtreecommitdiff
path: root/arch/powerpc/platforms/pseries
diff options
context:
space:
mode:
authorLinas Vepstas <linas@austin.ibm.com>2007-03-19 22:54:21 +0300
committerPaul Mackerras <paulus@samba.org>2007-03-22 14:52:52 +0300
commit147d6a37500348b6bda5738453d84c46678209cf (patch)
treeccc101c3901dd915bdfe86e3feac659124b037b3 /arch/powerpc/platforms/pseries
parent2fd30be8dae25386fc5167c34c6d73201334a8d4 (diff)
downloadlinux-147d6a37500348b6bda5738453d84c46678209cf.tar.xz
[POWERPC] EEH: support ibm,get-config-addr-info2 RTAS call
Provide support for the new ibm,get-config-addr-info2 RTAS token, whenever it is actually available. Signed-off-by: Linas Vepstas <linas@austin.ibm.com> Signed-off-by: Paul Mackerras <paulus@samba.org>
Diffstat (limited to 'arch/powerpc/platforms/pseries')
-rw-r--r--arch/powerpc/platforms/pseries/eeh.c44
1 files changed, 35 insertions, 9 deletions
diff --git a/arch/powerpc/platforms/pseries/eeh.c b/arch/powerpc/platforms/pseries/eeh.c
index 2d0a43f1efb4..44aae9193a90 100644
--- a/arch/powerpc/platforms/pseries/eeh.c
+++ b/arch/powerpc/platforms/pseries/eeh.c
@@ -83,6 +83,7 @@ static int ibm_read_slot_reset_state;
static int ibm_read_slot_reset_state2;
static int ibm_slot_error_detail;
static int ibm_get_config_addr_info;
+static int ibm_get_config_addr_info2;
static int ibm_configure_bridge;
int eeh_subsystem_enabled;
@@ -744,6 +745,38 @@ struct eeh_early_enable_info {
unsigned int buid_lo;
};
+static int get_pe_addr (int config_addr,
+ struct eeh_early_enable_info *info)
+{
+ unsigned int rets[3];
+ int ret;
+
+ /* Use latest config-addr token on power6 */
+ if (ibm_get_config_addr_info2 != RTAS_UNKNOWN_SERVICE) {
+ /* Make sure we have a PE in hand */
+ ret = rtas_call (ibm_get_config_addr_info2, 4, 2, rets,
+ config_addr, info->buid_hi, info->buid_lo, 1);
+ if (ret || (rets[0]==0))
+ return 0;
+
+ ret = rtas_call (ibm_get_config_addr_info2, 4, 2, rets,
+ config_addr, info->buid_hi, info->buid_lo, 0);
+ if (ret)
+ return 0;
+ return rets[0];
+ }
+
+ /* Use older config-addr token on power5 */
+ if (ibm_get_config_addr_info != RTAS_UNKNOWN_SERVICE) {
+ ret = rtas_call (ibm_get_config_addr_info, 4, 2, rets,
+ config_addr, info->buid_hi, info->buid_lo, 0);
+ if (ret)
+ return 0;
+ return rets[0];
+ }
+ return 0;
+}
+
/* Enable eeh for the given device node. */
static void *early_enable_eeh(struct device_node *dn, void *data)
{
@@ -810,15 +843,7 @@ static void *early_enable_eeh(struct device_node *dn, void *data)
/* If the newer, better, ibm,get-config-addr-info is supported,
* then use that instead. */
- pdn->eeh_pe_config_addr = 0;
- if (ibm_get_config_addr_info != RTAS_UNKNOWN_SERVICE) {
- ret = rtas_call (ibm_get_config_addr_info, 4, 2, rets,
- pdn->eeh_config_addr,
- info->buid_hi, info->buid_lo,
- 0);
- if (ret == 0)
- pdn->eeh_pe_config_addr = rets[0];
- }
+ pdn->eeh_pe_config_addr = get_pe_addr(pdn->eeh_config_addr, info);
/* Some older systems (Power4) allow the
* ibm,set-eeh-option call to succeed even on nodes
@@ -889,6 +914,7 @@ void __init eeh_init(void)
ibm_read_slot_reset_state = rtas_token("ibm,read-slot-reset-state");
ibm_slot_error_detail = rtas_token("ibm,slot-error-detail");
ibm_get_config_addr_info = rtas_token("ibm,get-config-addr-info");
+ ibm_get_config_addr_info2 = rtas_token("ibm,get-config-addr-info2");
ibm_configure_bridge = rtas_token ("ibm,configure-bridge");
if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE)