diff options
author | Hans Verkuil <hans.verkuil@cisco.com> | 2013-03-18 20:20:00 +0400 |
---|---|---|
committer | Mauro Carvalho Chehab <mchehab@redhat.com> | 2013-03-25 16:25:53 +0400 |
commit | 820eac0ef8b86f7275acd1f8bccfb0b30f17bbe9 (patch) | |
tree | c64f011b39810ef775955e94154161cffa73c216 /Documentation/DocBook | |
parent | 9d5f4839cc098f15a48f7063d39805ddfe84565c (diff) | |
download | linux-820eac0ef8b86f7275acd1f8bccfb0b30f17bbe9.tar.xz |
[media] DocBook media: fix syntax problems in dvbproperty.xml
Caught by xmllint.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@redhat.com>
Diffstat (limited to 'Documentation/DocBook')
-rw-r--r-- | Documentation/DocBook/media/dvb/dvbproperty.xml | 46 |
1 files changed, 22 insertions, 24 deletions
diff --git a/Documentation/DocBook/media/dvb/dvbproperty.xml b/Documentation/DocBook/media/dvb/dvbproperty.xml index 31dc4dfd1d6a..a9b15e34c5b2 100644 --- a/Documentation/DocBook/media/dvb/dvbproperty.xml +++ b/Documentation/DocBook/media/dvb/dvbproperty.xml @@ -903,14 +903,12 @@ enum fe_interleaving { <constant>svalue</constant> is for signed values of the measure (dB measures) and <constant>uvalue</constant> is for unsigned values (counters, relative scale)</para></listitem> <listitem><para><constant>scale</constant> - Scale for the value. It can be:</para> - <section id = "fecap-scale-params"> - <itemizedlist mark='bullet'> + <itemizedlist mark='bullet' id="fecap-scale-params"> <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - The parameter is supported by the frontend, but it was not possible to collect it (could be a transitory or permanent condition)</para></listitem> <listitem><para><constant>FE_SCALE_DECIBEL</constant> - parameter is a signed value, measured in 1/1000 dB</para></listitem> <listitem><para><constant>FE_SCALE_RELATIVE</constant> - parameter is a unsigned value, where 0 means 0% and 65535 means 100%.</para></listitem> <listitem><para><constant>FE_SCALE_COUNTER</constant> - parameter is a unsigned value that counts the occurrence of an event, like bit error, block error, or lapsed time.</para></listitem> </itemizedlist> - </section> </listitem> </itemizedlist> <section id="DTV-STAT-SIGNAL-STRENGTH"> @@ -918,9 +916,9 @@ enum fe_interleaving { <para>Indicates the signal strength level at the analog part of the tuner or of the demod.</para> <para>Possible scales for this metric are:</para> <itemizedlist mark='bullet'> - <listitem><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</listitem> - <listitem><constant>FE_SCALE_DECIBEL</constant> - signal strength is in 0.0001 dBm units, power measured in miliwatts. This value is generally negative.</listitem> - <listitem><constant>FE_SCALE_RELATIVE</constant> - The frontend provides a 0% to 100% measurement for power (actually, 0 to 65535).</listitem> + <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</para></listitem> + <listitem><para><constant>FE_SCALE_DECIBEL</constant> - signal strength is in 0.0001 dBm units, power measured in miliwatts. This value is generally negative.</para></listitem> + <listitem><para><constant>FE_SCALE_RELATIVE</constant> - The frontend provides a 0% to 100% measurement for power (actually, 0 to 65535).</para></listitem> </itemizedlist> </section> <section id="DTV-STAT-CNR"> @@ -928,9 +926,9 @@ enum fe_interleaving { <para>Indicates the Signal to Noise ratio for the main carrier.</para> <para>Possible scales for this metric are:</para> <itemizedlist mark='bullet'> - <listitem><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</listitem> - <listitem><constant>FE_SCALE_DECIBEL</constant> - Signal/Noise ratio is in 0.0001 dB units.</listitem> - <listitem><constant>FE_SCALE_RELATIVE</constant> - The frontend provides a 0% to 100% measurement for Signal/Noise (actually, 0 to 65535).</listitem> + <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</para></listitem> + <listitem><para><constant>FE_SCALE_DECIBEL</constant> - Signal/Noise ratio is in 0.0001 dB units.</para></listitem> + <listitem><para><constant>FE_SCALE_RELATIVE</constant> - The frontend provides a 0% to 100% measurement for Signal/Noise (actually, 0 to 65535).</para></listitem> </itemizedlist> </section> <section id="DTV-STAT-PRE-ERROR-BIT-COUNT"> @@ -943,8 +941,8 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned.</para> <para>Possible scales for this metric are:</para> <itemizedlist mark='bullet'> - <listitem><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</listitem> - <listitem><constant>FE_SCALE_COUNTER</constant> - Number of error bits counted before the inner coding.</listitem> + <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</para></listitem> + <listitem><para><constant>FE_SCALE_COUNTER</constant> - Number of error bits counted before the inner coding.</para></listitem> </itemizedlist> </section> <section id="DTV-STAT-PRE-TOTAL-BIT-COUNT"> @@ -957,9 +955,9 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned.</para> <para>Possible scales for this metric are:</para> <itemizedlist mark='bullet'> - <listitem><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</listitem> - <listitem><constant>FE_SCALE_COUNTER</constant> - Number of bits counted while measuring - <link linkend="DTV-STAT-PRE-ERROR-BIT-COUNT"><constant>DTV_STAT_PRE_ERROR_BIT_COUNT</constant></link>.</listitem> + <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</para></listitem> + <listitem><para><constant>FE_SCALE_COUNTER</constant> - Number of bits counted while measuring + <link linkend="DTV-STAT-PRE-ERROR-BIT-COUNT"><constant>DTV_STAT_PRE_ERROR_BIT_COUNT</constant></link>.</para></listitem> </itemizedlist> </section> <section id="DTV-STAT-POST-ERROR-BIT-COUNT"> @@ -972,8 +970,8 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned.</para> <para>Possible scales for this metric are:</para> <itemizedlist mark='bullet'> - <listitem><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</listitem> - <listitem><constant>FE_SCALE_COUNTER</constant> - Number of error bits counted after the inner coding.</listitem> + <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</para></listitem> + <listitem><para><constant>FE_SCALE_COUNTER</constant> - Number of error bits counted after the inner coding.</para></listitem> </itemizedlist> </section> <section id="DTV-STAT-POST-TOTAL-BIT-COUNT"> @@ -986,9 +984,9 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned.</para> <para>Possible scales for this metric are:</para> <itemizedlist mark='bullet'> - <listitem><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</listitem> - <listitem><constant>FE_SCALE_COUNTER</constant> - Number of bits counted while measuring - <link linkend="DTV-STAT-POST-ERROR-BIT-COUNT"><constant>DTV_STAT_POST_ERROR_BIT_COUNT</constant></link>.</listitem> + <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</para></listitem> + <listitem><para><constant>FE_SCALE_COUNTER</constant> - Number of bits counted while measuring + <link linkend="DTV-STAT-POST-ERROR-BIT-COUNT"><constant>DTV_STAT_POST_ERROR_BIT_COUNT</constant></link>.</para></listitem> </itemizedlist> </section> <section id="DTV-STAT-ERROR-BLOCK-COUNT"> @@ -998,8 +996,8 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned.</para> <para>Possible scales for this metric are:</para> <itemizedlist mark='bullet'> - <listitem><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</listitem> - <listitem><constant>FE_SCALE_COUNTER</constant> - Number of error blocks counted after the outer coding.</listitem> + <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</para></listitem> + <listitem><para><constant>FE_SCALE_COUNTER</constant> - Number of error blocks counted after the outer coding.</para></listitem> </itemizedlist> </section> <section id="DTV-STAT-TOTAL-BLOCK-COUNT"> @@ -1011,9 +1009,9 @@ enum fe_interleaving { by <link linkend="DTV-STAT-TOTAL-BLOCK-COUNT"><constant>DTV-STAT-TOTAL-BLOCK-COUNT</constant></link>.</para> <para>Possible scales for this metric are:</para> <itemizedlist mark='bullet'> - <listitem><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</listitem> - <listitem><constant>FE_SCALE_COUNTER</constant> - Number of blocks counted while measuring - <link linkend="DTV-STAT-ERROR-BLOCK-COUNT"><constant>DTV_STAT_ERROR_BLOCK_COUNT</constant></link>.</listitem> + <listitem><para><constant>FE_SCALE_NOT_AVAILABLE</constant> - it failed to measure it, or the measurement was not complete yet.</para></listitem> + <listitem><para><constant>FE_SCALE_COUNTER</constant> - Number of blocks counted while measuring + <link linkend="DTV-STAT-ERROR-BLOCK-COUNT"><constant>DTV_STAT_ERROR_BLOCK_COUNT</constant></link>.</para></listitem> </itemizedlist> </section> </section> |