diff options
author | Jacek Anaszewski <j.anaszewski@samsung.com> | 2015-03-04 19:14:23 +0300 |
---|---|---|
committer | Bryan Wu <cooloney@gmail.com> | 2015-03-10 03:16:28 +0300 |
commit | 9c4a8e138cfe2cc7262d5d2224162add5632b546 (patch) | |
tree | 4bdb86c578d7b863daf78c92bc9a74ce5862626b /Documentation/ABI | |
parent | 94fdec768dc72a6993479f59a17daa413f30029e (diff) | |
download | linux-9c4a8e138cfe2cc7262d5d2224162add5632b546.tar.xz |
leds: flash: document sysfs interface
Add a documentation of LED Flash class specific sysfs attributes.
Signed-off-by: Jacek Anaszewski <j.anaszewski@samsung.com>
Acked-by: Kyungmin Park <kyungmin.park@samsung.com>
Cc: Richard Purdie <rpurdie@rpsys.net>
Signed-off-by: Bryan Wu <cooloney@gmail.com>
Diffstat (limited to 'Documentation/ABI')
-rw-r--r-- | Documentation/ABI/testing/sysfs-class-led-flash | 80 |
1 files changed, 80 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-led-flash b/Documentation/ABI/testing/sysfs-class-led-flash new file mode 100644 index 000000000000..220a0270b47b --- /dev/null +++ b/Documentation/ABI/testing/sysfs-class-led-flash @@ -0,0 +1,80 @@ +What: /sys/class/leds/<led>/flash_brightness +Date: March 2015 +KernelVersion: 4.0 +Contact: Jacek Anaszewski <j.anaszewski@samsung.com> +Description: read/write + Set the brightness of this LED in the flash strobe mode, in + microamperes. The file is created only for the flash LED devices + that support setting flash brightness. + + The value is between 0 and + /sys/class/leds/<led>/max_flash_brightness. + +What: /sys/class/leds/<led>/max_flash_brightness +Date: March 2015 +KernelVersion: 4.0 +Contact: Jacek Anaszewski <j.anaszewski@samsung.com> +Description: read only + Maximum brightness level for this LED in the flash strobe mode, + in microamperes. + +What: /sys/class/leds/<led>/flash_timeout +Date: March 2015 +KernelVersion: 4.0 +Contact: Jacek Anaszewski <j.anaszewski@samsung.com> +Description: read/write + Hardware timeout for flash, in microseconds. The flash strobe + is stopped after this period of time has passed from the start + of the strobe. The file is created only for the flash LED + devices that support setting flash timeout. + +What: /sys/class/leds/<led>/max_flash_timeout +Date: March 2015 +KernelVersion: 4.0 +Contact: Jacek Anaszewski <j.anaszewski@samsung.com> +Description: read only + Maximum flash timeout for this LED, in microseconds. + +What: /sys/class/leds/<led>/flash_strobe +Date: March 2015 +KernelVersion: 4.0 +Contact: Jacek Anaszewski <j.anaszewski@samsung.com> +Description: read/write + Flash strobe state. When written with 1 it triggers flash strobe + and when written with 0 it turns the flash off. + + On read 1 means that flash is currently strobing and 0 means + that flash is off. + +What: /sys/class/leds/<led>/flash_fault +Date: March 2015 +KernelVersion: 4.0 +Contact: Jacek Anaszewski <j.anaszewski@samsung.com> +Description: read only + Space separated list of flash faults that may have occurred. + Flash faults are re-read after strobing the flash. Possible + flash faults: + + * led-over-voltage - flash controller voltage to the flash LED + has exceeded the limit specific to the flash controller + * flash-timeout-exceeded - the flash strobe was still on when + the timeout set by the user has expired; not all flash + controllers may set this in all such conditions + * controller-over-temperature - the flash controller has + overheated + * controller-short-circuit - the short circuit protection + of the flash controller has been triggered + * led-power-supply-over-current - current in the LED power + supply has exceeded the limit specific to the flash + controller + * indicator-led-fault - the flash controller has detected + a short or open circuit condition on the indicator LED + * led-under-voltage - flash controller voltage to the flash + LED has been below the minimum limit specific to + the flash + * controller-under-voltage - the input voltage of the flash + controller is below the limit under which strobing the + flash at full current will not be possible; + the condition persists until this flag is no longer set + * led-over-temperature - the temperature of the LED has exceeded + its allowed upper limit |