1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
|
.. -*- coding: utf-8; mode: rst -*-
.. _lirc_dev_intro:
************
Introduction
************
LIRC stands for Linux Infrared Remote Control. The LIRC device interface is
a bi-directional interface for transporting raw IR and decoded scancodes
data between userspace and kernelspace. Fundamentally, it is just a chardev
(/dev/lircX, for X = 0, 1, 2, ...), with a number of standard struct
file_operations defined on it. With respect to transporting raw IR and
decoded scancodes to and fro, the essential fops are read, write and ioctl.
Example dmesg output upon a driver registering w/LIRC:
.. code-block:: none
$ dmesg |grep lirc_dev
rc rc0: lirc_dev: driver mceusb registered at minor = 0
What you should see for a chardev:
.. code-block:: none
$ ls -l /dev/lirc*
crw-rw---- 1 root root 248, 0 Jul 2 22:20 /dev/lirc0
.. _lirc_modes:
**********
LIRC modes
**********
LIRC supports some modes of receiving and sending IR codes, as shown
on the following table.
.. _lirc-mode-scancode:
.. _lirc-scancode-flag-toggle:
.. _lirc-scancode-flag-repeat:
``LIRC_MODE_SCANCODE``
This mode is for both sending and receiving IR.
For transmitting (aka sending), create a ``struct lirc_scancode`` with
the desired scancode set in the ``scancode`` member, :c:type:`rc_proto`
set the IR protocol, and all other members set to 0. Write this struct to
the lirc device.
For receiving, you read ``struct lirc_scancode`` from the lirc device,
with ``scancode`` set to the received scancode and the IR protocol
:c:type:`rc_proto`. If the scancode maps to a valid key code, this is set
in the ``keycode`` field, else it is set to ``KEY_RESERVED``.
The ``flags`` can have ``LIRC_SCANCODE_FLAG_TOGGLE`` set if the toggle
bit is set in protocols that support it (e.g. rc-5 and rc-6), or
``LIRC_SCANCODE_FLAG_REPEAT`` for when a repeat is received for protocols
that support it (e.g. nec).
In the Sanyo and NEC protocol, if you hold a button on remote, rather than
repeating the entire scancode, the remote sends a shorter message with
no scancode, which just means button is held, a "repeat". When this is
received, the ``LIRC_SCANCODE_FLAG_REPEAT`` is set and the scancode and
keycode is repeated.
With nec, there is no way to distinguish "button hold" from "repeatedly
pressing the same button". The rc-5 and rc-6 protocols have a toggle bit.
When a button is released and pressed again, the toggle bit is inverted.
If the toggle bit is set, the ``LIRC_SCANCODE_FLAG_TOGGLE`` is set.
The ``timestamp`` field is filled with the time nanoseconds
(in ``CLOCK_MONOTONIC``) when the scancode was decoded.
.. _lirc-mode-mode2:
``LIRC_MODE_MODE2``
The driver returns a sequence of pulse and space codes to userspace,
as a series of u32 values.
This mode is used only for IR receive.
The upper 8 bits determine the packet type, and the lower 24 bits
the payload. Use ``LIRC_VALUE()`` macro to get the payload, and
the macro ``LIRC_MODE2()`` will give you the type, which
is one of:
``LIRC_MODE2_PULSE``
Signifies the presence of IR in microseconds.
``LIRC_MODE2_SPACE``
Signifies absence of IR in microseconds.
``LIRC_MODE2_FREQUENCY``
If measurement of the carrier frequency was enabled with
:ref:`lirc_set_measure_carrier_mode` then this packet gives you
the carrier frequency in Hertz.
``LIRC_MODE2_TIMEOUT``
If timeout reports are enabled with
:ref:`lirc_set_rec_timeout_reports`, when the timeout set with
:ref:`lirc_set_rec_timeout` expires due to no IR being detected,
this packet will be sent, with the number of microseconds with
no IR.
.. _lirc-mode-pulse:
``LIRC_MODE_PULSE``
In pulse mode, a sequence of pulse/space integer values are written to the
lirc device using :ref:`lirc-write`.
The values are alternating pulse and space lengths, in microseconds. The
first and last entry must be a pulse, so there must be an odd number
of entries.
This mode is used only for IR send.
**************************
Remote Controller protocol
**************************
An enum :c:type:`rc_proto` in the :ref:`lirc_header` lists all the
supported IR protocols:
.. kernel-doc:: include/uapi/linux/lirc.h
|