From 17abc9ec68b73ddeb262a507a62421016b9c54d5 Mon Sep 17 00:00:00 2001 From: Tomasz Duszynski Date: Fri, 14 Dec 2018 19:28:01 +0100 Subject: iio: add IIO_MASSCONCENTRATION channel type Measuring particulate matter in ug / m3 (micro-grams per cubic meter) is de facto standard. Existing air quality sensors usually follow this convention and are capable of returning measurements using this unit. IIO currently does not offer suitable channel type for this type of measurements hence this patch adds this. In addition, extra modifiers are introduced used for distinguishing between fine pm1, pm2p5 and coarse pm4, pm10 particle measurements, i.e IIO_MOD_PM1, IIO_MOD_PM25 and IIO_MOD_PM4, IIO_MOD_PM10. pmX consists of particles with aerodynamic diameter less or equal to X micrometers. Signed-off-by: Tomasz Duszynski Acked-by: Matt Ranostay Signed-off-by: Jonathan Cameron --- include/uapi/linux/iio/types.h | 5 +++++ 1 file changed, 5 insertions(+) (limited to 'include') diff --git a/include/uapi/linux/iio/types.h b/include/uapi/linux/iio/types.h index 92baabc103ac..c59adac24b1c 100644 --- a/include/uapi/linux/iio/types.h +++ b/include/uapi/linux/iio/types.h @@ -46,6 +46,7 @@ enum iio_chan_type { IIO_GRAVITY, IIO_POSITIONRELATIVE, IIO_PHASE, + IIO_MASSCONCENTRATION, }; enum iio_modifier { @@ -87,6 +88,10 @@ enum iio_modifier { IIO_MOD_VOC, IIO_MOD_LIGHT_UV, IIO_MOD_LIGHT_DUV, + IIO_MOD_PM1, + IIO_MOD_PM2P5, + IIO_MOD_PM4, + IIO_MOD_PM10, }; enum iio_event_type { -- cgit v1.2.3