summaryrefslogtreecommitdiff
path: root/include/linux/mlx5
AgeCommit message (Collapse)AuthorFilesLines
2019-04-23net/mlx5e: XDP, Inline small packets into the TX MPWQE in XDP xmit flowShay Agroskin1-0/+1
Upon high packet rate with multiple CPUs TX workloads, much of the HCA's resources are spent on prefetching TX descriptors, thus affecting transmission rates. This patch comes to mitigate this problem by moving some workload to the CPU and reducing the HW data prefetch overhead for small packets (<= 256B). When forwarding packets with XDP, a packet that is smaller than a certain size (set to ~256 bytes) would be sent inline within its WQE TX descrptor (mem-copied), when the hardware tx queue is congested beyond a pre-defined water-mark. This is added to better utilize the HW resources (which now makes one less packet data prefetch) and allow better scalability, on the account of CPU usage (which now 'memcpy's the packet into the WQE). To load balance between HW and CPU and get max packet rate, we use watermarks to detect how much the HW is congested and move the work loads back and forth between HW and CPU. Performance: Tested packet rate for UDP 64Byte multi-stream over two dual port ConnectX-5 100Gbps NICs. CPU: Intel(R) Xeon(R) CPU E5-2680 v3 @ 2.50GHz * Tested with hyper-threading disabled XDP_TX: | | before | after | | | 24 rings | 51Mpps | 116Mpps | +126% | | 1 ring | 12Mpps | 12Mpps | same | XDP_REDIRECT: ** Below is the transmit rate, not the redirection rate which might be larger, and is not affected by this patch. | | before | after | | | 32 rings | 64Mpps | 92Mpps | +43% | | 1 ring | 6.4Mpps | 6.4Mpps | same | As we can see, feature significantly improves scaling, without hurting single ring performance. Signed-off-by: Shay Agroskin <shayag@mellanox.com> Signed-off-by: Tariq Toukan <tariqt@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-04-23Merge branch 'mlx5-next' of ↵Saeed Mahameed1-0/+6
git://git.kernel.org/pub/scm/linux/kernel/git/mellanox/linux
2019-04-23Merge tag 'v5.1-rc1' of ↵Saeed Mahameed5-20/+48
git://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux into mlx5-next Linux 5.1-rc1 We forgot to reset the branch last merge window thus mlx5-next is outdated and still based on 5.0-rc2. This merge commit is needed to sync mlx5-next branch with 5.1-rc1. Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-04-10net/mlx5: E-Switch, add a new prio to be used by the RDMA sideMark Bloch1-0/+1
Create a new prio in the FDB, it will be used when inserting steering rules into the FDB from the RDMA side. We create a new PRIO so rules from the net side and rules from the RDMA side won't be inserted to the same PRIO, each side has it's own sandbox to play in. Signed-off-by: Mark Bloch <markb@mellanox.com> Reviewed-by: Maor Gottlieb <maorg@mellanox.com> Signed-off-by: Leon Romanovsky <leonro@mellanox.com>
2019-04-10net/mlx5: E-Switch, don't use hardcoded values for FDB priosMark Bloch1-0/+5
When creating the FDB prios, use the enum values already defined and not the hardcoded values. Signed-off-by: Mark Bloch <markb@mellanox.com> Reviewed-by: Maor Gottlieb <maorg@mellanox.com> Signed-off-by: Leon Romanovsky <leonro@mellanox.com>
2019-04-09Merge tag 'mlx5-updates-2019-04-02' of ↵David S. Miller5-32/+64
git://git.kernel.org/pub/scm/linux/kernel/git/saeed/linux Saeed Mamameed says: ==================== mlx5-updates-2019-04-02 This series provides misc updates to mlx5 driver 1) Aya Levin (1): Handle event of power detection in the PCIE slot 2) Eli Britstein (6): Some TC VLAN related updates and fixes to the previous VLAN modify action support patchset. Offload TC e-switch rules with egress/ingress VLAN devices 3) Max Gurtovoy (1): Fix double mutex initialization in esiwtch.c 4) Tariq Toukan (3): Misc small updates A write memory barrier is sufficient in EQ ci update Obsolete param field holding a constant value Unify logic of MTU boundaries 5) Tonghao Zhang (4): Misc updates to en_tc.c Make the log friendly when decapsulation offload not supported Remove 'parse_attr' argument in parse_tc_fdb_actions() Deletes unnecessary setting of esw_attr->parse_attr Return -EOPNOTSUPP when attempting to offload an unsupported action ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
2019-04-06Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/netDavid S. Miller1-0/+2
Minor comment merge conflict in mlx5. Staging driver has a fixup due to the skb->xmit_more changes in 'net-next', but was removed in 'net'. Signed-off-by: David S. Miller <davem@davemloft.net>
2019-04-06net/mlx5: Handle event of power detection in the PCIE slotAya Levin1-0/+1
Handle event of power state change in the PCIE slot. When the event occurs, check if query power state and PCI power fields is supported. If so, read these fields from MPEIN (management PCIE info) register and issue a corresponding message. Signed-off-by: Aya Levin <ayal@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-04-06Merge branch 'mlx5-next' of ↵Saeed Mahameed4-32/+63
git://git.kernel.org/pub/scm/linux/kernel/git/mellanox/linux This merge commit includes some misc shared code updates from mlx5-next branch needed for net-next. 1) From Maxim, Remove un-used macros and spinlock from mlx5 code. 2) From Aya, Expose Management PCIE info register layout and add rate limit print macros. 3) From Tariq, Compilation warning fix in fs_core.c 4) From Vu, Huy and Saeed, Improve mlx5 initialization flow: The goal is to provide a better logical separation of mlx5 core device initialization flow and will help to seamlessly support creating different mlx5 device types such as PF, VF and SF mlx5 sub-function virtual devices. Mlx5_core driver needs to separate HCA resources from pci resources. Its initialize/load/unload will be broken into stages: 1. Initialize common data structures 2. Setup function which initializes pci resources (for PF/VF) or some other specific resources for virtual device 3. Initialize software objects according to hardware capabilities 4. Load all mlx5_core components It is also necessary to detach mlx5_core mdev name/message from pci device mdev->pdev name/message for a clearer report/debug of different mlx5 device types. Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-04-02net/mlx5: Expose MPEIN (Management PCIE INfo) register layoutAya Levin2-1/+51
Expose PRM layout for handling MPEIN (Management PCIE Info). It will be used in the downstream patch for querying MPEIN via the driver. Signed-off-by: Aya Levin <ayal@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-04-02net/mlx5: Add explicit bar address fieldHuy Nguyen1-0/+1
Add bar_addr field to store bar-0 address to avoid calling pci_resource_start with hard-coded bar-0 as parameter. Also note that different mlx5 device types will have bar_addr on different bars. This patch does not change any functionality. Signed-off-by: Huy Nguyen <huyn@mellanox.com> Signed-off-by: Vu Pham <vuhuong@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-04-02net/mlx5: Move health and page alloc init to mdev_initSaeed Mahameed1-0/+1
Software structure initialization should be in mdev_init stage. This provides a better logical separation of mlx5 core device initialization flow and will help to seamlessly support creating different mlx5 device types such as PF, VF and SF mlx5 sub-function virtual device. This patch does not change any functionality. Signed-off-by: Vu Pham <vuhuong@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-04-02net/mlx5: Remove spinlock support from mlx5_write64Maxim Mikityanskiy2-23/+10
As there is no user of mlx5_write64 that passes a spinlock to mlx5_write64, remove this functionality and simplify the function. Signed-off-by: Maxim Mikityanskiy <maximmi@mellanox.com> Reviewed-by: Eran Ben Elisha <eranbe@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-04-02net/mlx5: Remove unused MLX5_*_DOORBELL_LOCK macrosMaxim Mikityanskiy1-8/+0
MLX5_*_DOORBELL_LOCK macros provided a way to avoid locking for mlx5_write64 on 64-bit platforms where it's not necessary. Currently all calls to mlx5_write64 don't use a spinlock, so the macros became unused. Signed-off-by: Maxim Mikityanskiy <maximmi@mellanox.com> Reviewed-by: Eran Ben Elisha <eranbe@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-03-29net/mlx5e: Add a lock on tir listYuval Avnery1-0/+2
Refresh tirs is looping over a global list of tirs while netdevs are adding and removing tirs from that list. That is why a lock is required. Fixes: 724b2aa15126 ("net/mlx5e: TIRs management refactoring") Signed-off-by: Yuval Avnery <yuvalav@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-03-28Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/netDavid S. Miller1-1/+2
2019-03-22net/mlx5e: Add VLAN ID rewrite fieldsEli Britstein1-0/+1
Add VLAN ID rewrite fields as a pre-step to support this rewrite. Signed-off-by: Eli Britstein <elibr@mellanox.com> Reviewed-by: Roi Dayan <roid@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-03-18IB/mlx5: Use mlx5 core to create/destroy a DEVX DCTYishai Hadas1-1/+2
To prevent a hardware memory leak when a DEVX DCT object is destroyed without calling DRAIN DCT before, (e.g. under cleanup flow), need to manage its creation and destruction via mlx5 core. In that case the DRAIN DCT command will be called and only once that it will be completed the DESTROY DCT command will be called. Otherwise, the DESTROY DCT may fail and a hardware leak may occur. As of that change the DRAIN DCT command should not be exposed any more from DEVX, it's managed internally by the driver to work as expected by the device specification. Fixes: 7efce3691d33 ("IB/mlx5: Add obj create and destroy functionality") Signed-off-by: Yishai Hadas <yishaih@mellanox.com> Reviewed-by: Artemy Kovalyov <artemyko@mellanox.com> Signed-off-by: Leon Romanovsky <leonro@mellanox.com> Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>
2019-03-10Merge tag 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/rdma/rdmaLinus Torvalds1-4/+1
Pull rdma updates from Jason Gunthorpe: "This has been a slightly more active cycle than normal with ongoing core changes and quite a lot of collected driver updates. - Various driver fixes for bnxt_re, cxgb4, hns, mlx5, pvrdma, rxe - A new data transfer mode for HFI1 giving higher performance - Significant functional and bug fix update to the mlx5 On-Demand-Paging MR feature - A chip hang reset recovery system for hns - Change mm->pinned_vm to an atomic64 - Update bnxt_re to support a new 57500 chip - A sane netlink 'rdma link add' method for creating rxe devices and fixing the various unregistration race conditions in rxe's unregister flow - Allow lookup up objects by an ID over netlink - Various reworking of the core to driver interface: - drivers should not assume umem SGLs are in PAGE_SIZE chunks - ucontext is accessed via udata not other means - start to make the core code responsible for object memory allocation - drivers should convert struct device to struct ib_device via a helper - drivers have more tools to avoid use after unregister problems" * tag 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/rdma/rdma: (280 commits) net/mlx5: ODP support for XRC transport is not enabled by default in FW IB/hfi1: Close race condition on user context disable and close RDMA/umem: Revert broken 'off by one' fix RDMA/umem: minor bug fix in error handling path RDMA/hns: Use GFP_ATOMIC in hns_roce_v2_modify_qp cxgb4: kfree mhp after the debug print IB/rdmavt: Fix concurrency panics in QP post_send and modify to error IB/rdmavt: Fix loopback send with invalidate ordering IB/iser: Fix dma_nents type definition IB/mlx5: Set correct write permissions for implicit ODP MR bnxt_re: Clean cq for kernel consumers only RDMA/uverbs: Don't do double free of allocated PD RDMA: Handle ucontext allocations by IB/core RDMA/core: Fix a WARN() message bnxt_re: fix the regression due to changes in alloc_pbl IB/mlx4: Increase the timeout for CM cache IB/core: Abort page fault handler silently during owning process exit IB/mlx5: Validate correct PD before prefetch MR IB/mlx5: Protect against prefetch of invalid MR RDMA/uverbs: Store PR pointer before it is overwritten ...
2019-03-01net/mlx5: Emit port affinity event for multipath offloadsRoi Dayan1-0/+1
Under multipath offload scheme, as part of handling fib events, emit mlx5 port affinity event on the enabled ports which will be handled by the tc offloads code. Signed-off-by: Roi Dayan <roid@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-03-01net/mlx5: Add multipath modeRoi Dayan1-0/+1
In order to offload ecmp-on-host scheme where next-hop routes are used, we will make use of HW LAG. Add accessor function to let upper layers in the driver to realize if the lag acts in multi-path mode. Signed-off-by: Roi Dayan <roid@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-23net/mlx5e: Fix GRE key by controlling port tunnel entropy calculationEli Britstein1-0/+2
Flow entropy is calculated on the inner packet headers and used for flow distribution in processing, routing etc. For GRE-type encapsulations the entropy value is placed in the eight LSB of the key field in the GRE header as defined in NVGRE RFC 7637. For UDP based encapsulations the entropy value is placed in the source port of the UDP header. The hardware may support entropy calculation specifically for GRE and for all tunneling protocols. With commit df2ef3bff193 ("net/mlx5e: Add GRE protocol offloading") GRE is offloaded, but the hardware is configured by default to calculate flow entropy so packets transmitted on the wire have a wrong key. To support UDP based tunnels (i.e VXLAN), GRE (i.e. no flow entropy) and NVGRE (i.e. with flow entropy) the hardware behaviour must be controlled by the driver. Ensure port entropy calculation is enabled for offloaded VXLAN tunnels and disable port entropy calculation in the presence of offloaded GRE tunnels by monitoring the presence of entropy enabling tunnels (i.e VXLAN) and entropy disabing tunnels (i.e GRE). Fixes: df2ef3bff193 ("net/mlx5e: Add GRE protocol offloading") Signed-off-by: Eli Britstein <elibr@mellanox.com> Reviewed-by: Oz Shlomo <ozsh@mellanox.com> Reviewed-by: Roi Dayan <roid@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-23net/mlx5: Introduce tunnel entropy control in PCMR registerEli Britstein1-2/+10
When using the device packet encapsulation offload, the device calculates an entropy value, representing the inner packet headers. The entropy field is placed inside the outer packet headers. For UDP-type encapsulations, the entropy is placed in the source port field of the UDP header. For GRE-type encapsulations, the entropy is placed in the 8 LSB of the key field in the GRE header. If the device does not recognize the encapsulation type, the entropy is not placed in the packet. Entropy setting can be controlled using PCMR register. if encapsulation offload is not used force_entropy_cap should be set to 0x0. Entropy setting is enabled/disabled using entropy_calc, and could be additionally enabled/disabled for GRE encapsulation by entropy_gre_calc. As a pre-step to automatically control the tunnel entropy, introduce the entropy fields in the PCMR register with no functional change. Signed-off-by: Eli Britstein <elibr@mellanox.com> Reviewed-by: Oz Shlomo <ozsh@mellanox.com> Reviewed-by: Roi Dayan <roid@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-21Merge branch 'mlx5-next' into rdma.git for-nextJason Gunthorpe5-33/+122
From git://git.kernel.org/pub/scm/linux/kernel/git/mellanox/linux To resolve conflicts with net-next and pick up the first patch. * branch 'mlx5-next': net/mlx5: Factor out HCA capabilities functions IB/mlx5: Add support for 50Gbps per lane link modes net/mlx5: Add support to ext_* fields introduced in Port Type and Speed register net/mlx5: Add new fields to Port Type and Speed register net/mlx5: Refactor queries to speed fields in Port Type and Speed register net/mlx5: E-Switch, Avoid magic numbers when initializing offloads mode net/mlx5: Relocate vport macros to the vport header file net/mlx5: E-Switch, Normalize the name of uplink vport number net/mlx5: Provide an alternative VF upper bound for ECPF net/mlx5: Add host params change event net/mlx5: Add query host params command net/mlx5: Update enable HCA dependency net/mlx5: Introduce Mellanox SmartNIC and modify page management logic IB/mlx5: Use unified register/load function for uplink and VF vports net/mlx5: Use consistent vport num argument type net/mlx5: Use void pointer as the type in address_of macro net/mlx5: Align ODP capability function with netdev coding style mlx5: use RCU lock in mlx5_eq_cq_get() Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>
2019-02-16net/mlx5: E-Switch, Consider ECPF vport depends on eswitch ownershipBodong Wang3-4/+12
ECPF connects to the eswitch through vport 0xfffe. ECPF may or may not be the eswitch manager depending on firmware configuration. 1. If ECPF is eswitch manager: ECPF will take over the eswitch manager responsibility. A rep of the host PF shall be created at the ECPF side for the eswitch manager to control. 2. If ECPF is not eswitch manager: host PF will be the eswitch manager, ECPF acts similar as a VF to the host PF. Host PF will be aware of the ECPF vport presence and control it's rep. Signed-off-by: Bodong Wang <bodong@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-16net/mlx5: E-Switch, Assign a different position for uplink rep and vportBodong Wang1-3/+8
In offloads mode, the current implementation puts the uplink representor at index zero of the vport reps array. It is not "natural" to place it at index 0 since we want to put the representor for vport 0 at index 0 with the introduction of SmartNIC. A separate patch will handle the case whether a rep is needed for vport 0 (PF vport). So, we want to have a different placeholder for uplink vport and representor. It was placed at the end of vport and rep array. Since vport number can no longer act as an index into the vport or representors arrays, use functions to map vport numbers to indices when accessing the vports or representors arrays, and vice versa. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-16net/mlx5: E-Switch, Centralize repersentor reg/unreg to eswitch driverBodong Wang1-7/+4
Eswitch has two users: IB and ETH. They both register repersentors when mlx5 interface is added, and unregister the repersentors when mlx5 interface is removed. Ideally, each driver should only deal with the entities which are unique to itself. However, current IB and ETH drivers have to perform the following eswitch operations: 1. When registering, specify how many vports to register. This number is the same for both drivers which is the total available vport numbers. 2. When unregistering, specify the number of registered vports to do unregister. Also, unload the repersentors which are already loaded. It's unnecessary for eswitch driver to hands out the control of above operations to individual driver users, as they're not unique to each driver. Instead, such operations should be centralized to eswitch driver. This consolidates eswitch control flow, and simplified IB and ETH driver. This patch doesn't change any functionality. Signed-off-by: Bodong Wang <bodong@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-16net/mlx5: E-Switch, Add state to eswitch vport representorsBodong Wang1-1/+7
Currently the eswitch vport reps have a valid indicator, which is set on register and unset on unregister. However, a rep can be loaded or not loaded when doing unregister, current driver checks if the vport of that rep is enabled as a flag to imply the rep is loaded. However, for ECPF, this is not valid as the host PF will enable the vports for its VFs instead. Add three states: {unregistered, registered, loaded}, with the following state changes across different operations: create: (none) -> unregistered reg: unregistered -> registered load: registered -> loaded unload: loaded -> registered unreg: registered -> unregistered Note that the state shall only be updated inside eswitch driver rather than individual drivers such as ETH or IB. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Suggested-by: Mark Bloch <markb@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-16net/mlx5: E-Switch, Split VF and special vports for offloads modeBodong Wang1-0/+1
When driver is entering offloads mode, there are two major tasks to do: initialize flow steering and create representors. Flow steering should make sure enough flow table/group spaces are reserved for all reps. Representors will be created in a group, all or none. With the introduction of ECPF, flow steering should still reserve the same spaces. But, the representors are not always loaded/unloaded in a single piece. Once ECPF is in offloads mode, it will get the number of VF changing event from host PF. In such scenario, only the VF reps should be loaded/unloaded, not the reps for special vports (such as the uplink vport). Thus, when entering offloads mode, driver should specify the total number of reps, and the number of VF reps separately. When leaving offloads mode, the cleanup should use the information self-contained in eswitch such as number of VFs. This patch doesn't change any functionality. Signed-off-by: Bodong Wang <bodong@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-16net/mlx5: E-Switch, Properly refer to host PF vport as other vportBodong Wang1-2/+2
Commands referring to vports use the following scheme: 1. When referring to my own vport, put 0 in vport and 0 in other_vport. 2. When referring to another vport, put the vport number of the referred vport and put 1 in other_vport. It was assumed that driver is accessing other vport when vport number is greater than 0. With the above scheme, the case that ECPF eswitch manager is trying to access host PF vport will fall over with scheme 1 as the vport number is 0. This is apparently wrong as driver is trying to refer other vport. As such usage can only happen in the eswitch context, change relevant functions to provide other vport input properly. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-16net/mlx5: E-Switch, Properly refer to the esw manager vportBodong Wang1-0/+2
In SmartNIC mode, the eswitch manager is not necessarily the PF (vport 0). Use a helper function to get the correct eswitch manager vport number and cache on the eswitch instance for fast reference. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Add support to ext_* fields introduced in Port Type and Speed registerAya Levin1-0/+19
This patch exposes new link modes (including 50Gbps per lane), and ext_* fields which describes the new link modes in Port Type and Speed register (PTYS). Access functions, translation functions (speed <-> HW bits) and link max speed function were modified. Signed-off-by: Aya Levin <ayal@mellanox.com> Reviewed-by: Eran Ben Elisha <eranbe@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Add new fields to Port Type and Speed registerAya Levin1-4/+8
Register Port Type and Speed (PTYS) introduces three new fields extending the speed/protocols the can be reported and configured. Signed-off-by: Aya Levin <ayal@mellanox.com> Reviewed-by: Eran Ben Elisha <eranbe@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Refactor queries to speed fields in Port Type and Speed registerAya Levin1-11/+0
This patch fascicles queries to speed related fields in Port Type and Speed register (PTYS) into a single API. I addition, this patch refactors functions which serves only Ethernet driver: remove the protocol type as an input parameter, move code from 'core' directory into 'en' directory and add 'eth' prefix to the function's name. The patch also encapsulates functions that are not used outside the Ethernet driver removes redundant include files. Signed-off-by: Aya Levin <ayal@mellanox.com> Reviewed-by: Eran Ben Elisha <eranbe@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: E-Switch, Avoid magic numbers when initializing offloads modeBodong Wang1-1/+3
When dealing with the offloads mode initialization, driver refers to the number of VFs and add magic number one (1) to take account of the uplink. This is not clear and will make the code less readable after adding other vports (e.g. host PF). As these are special vports compared to VF vports, add a helper macro to denote such special vports and eliminate the use of magic number. Moreover, when creating offloads flow table and groups, the driver reserves two more slots for UC and MC miss rules. Replace this magic number with a helper macro as well. This patch doesn't change any functionality. Signed-off-by: Bodong Wang <bodong@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Relocate vport macros to the vport header fileBodong Wang2-6/+7
These are two macros in the driver general header which deal with the number of total vports and if a vport is vport manager. Such macros are vport entities, better to place them at the vport header file. This patch doesn't change any functionality. Signed-off-by: Bodong Wang <bodong@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: E-Switch, Normalize the name of uplink vport numberBodong Wang1-0/+4
Driver used to name uplink vport as FDB_UPLINK_VPORT, it's hard to comply with the same naming convention along with the introduction of other vports. Use MLX5_VPORT as the prefix for such vports and relocate the uplink vport definition to public header file for the benefits of both net and IB drivers. This patch doesn't change any functionality. Signed-off-by: Bodong Wang <bodong@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Provide an alternative VF upper bound for ECPFBodong Wang1-1/+10
ECPF doesn't support SR-IOV, but an ECPF E-Switch manager shall know the max VFs supported by its peer host PF in order to control those VF vports. The current driver implementation uses the total vfs quantity as provided by the pci sub-system for an upper bound of the VF vports the e-switch code needs to deal with. This obviously can't work as is on ECPF e-switch manager. For now, we use a hard coded value of 128 on such systems. Signed-off-by: Bodong Wang <bodong@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Add host params change eventBodong Wang2-0/+7
In Embedded CPU (EC) configurations, the EC driver needs to know when the number of virtual functions change on the corresponding PF at the host side. This is required so the EC driver can create or destroy representor net devices that represent the VFs ports. Whenever a change in the number of VFs occurs, firmware will generate an event towards the EC which will trigger a work to complete the rest of the handling. The specifics of the handling will be introduced in a downstream patch. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Add query host params commandBodong Wang1-0/+41
The QUERY_HOST_PARAMS command is used by an Embedded CPU Physical Function (ECPF) driver to identify and retrieve information about the PF on the host side. E.g, number of virtual functions and PCI BDF. The number of VFs can be changed on the fly, a function is added to query current number of VFs and will be used in downstream patches. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Update enable HCA dependencyBodong Wang1-2/+4
With the introduction of ECPF, we require that the ECPF driver will aways call enable/disable HCA for that PF in the same way a PF does this for its VFs. The PF is still responsible for calling enable and disable HCA for its VFs. To distinguish between the ECPF executing enable/disable HCA for itself or for the PF, it sets the embedded CPU function bit in the input params struct of these commands. When the bit is cleared and function ID is zero, it refers to the peer PF. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Introduce Mellanox SmartNIC and modify page management logicBodong Wang3-6/+17
Mellanox's SmartNIC combines embedded CPU(e.g, ARM) processing power with advanced network offloads to accelerate a multitude of security, networking and storage applications. With the introduction of the SmartNIC, there is a new PCI function called Embedded CPU Physical Function(ECPF). And it's possible for a PF to get its ICM pages from the ECPF PCI function. Driver shall identify if it is running on such a function by reading a bit in the initialization segment. When firmware asks for pages, it would issue a page request event specifying how many pages it requests and for which function. That driver responds with a manage_pages command providing the requested pages along with an indication for which function it is providing these pages. The encoding before this patch was as follows: function_id == 0: pages are requested for the function receiving the EQE. function_id != 0: pages are requested for VF identified by the function_id value A new one bit field in the EQE identifies that pages are requested for the ECPF. The notion of page_supplier can be introduced here and to support that, manage pages and query pages were modified so firmware can distinguish the following cases: 1. Function provides pages for itself 2. PF provides pages for its VF 3. ECPF provides pages to itself 4. ECPF provides pages for another function This distinction is possible through the introduction of the bit "embedded_cpu_function" in query_pages, manage_pages and page request EQE. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Use consistent vport num argument typeBodong Wang1-4/+4
Use u16 for vport number, which matches how hardware refers to this argument throughout commands. This patch doesn't change any functionality. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-14net/mlx5: Use void pointer as the type in address_of macroBodong Wang1-1/+1
Better to use void * and avoid unnecessary casts. This patch doesn't change any functionality. Signed-off-by: Bodong Wang <bodong@mellanox.com> Signed-off-by: Eli Cohen <eli@mellanox.com> Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com> Reviewed-by: Daniel Jurgens <danielj@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
2019-02-05Merge branch 'mlx5-next into rdma.git for-nextJason Gunthorpe2-1/+7
From git://git.kernel.org/pub/scm/linux/kernel/git/mellanox/linux For dependencies needed in the next ODP patches. * branch 'mlx5-next': net/mlx5: Set ODP SRQ support in firmware net/mlx5: Add XRC transport to ODP device capabilities layout
2019-02-03net/mlx5: Set ODP SRQ support in firmwareMoni Shoua2-0/+4
To avoid compatibility issue with older kernels the firmware doesn't allow SRQ to work with ODP unless kernel asks for it. Signed-off-by: Moni Shoua <monis@mellanox.com> Reviewed-by: Majd Dibbiny <majd@mellanox.com> Signed-off-by: Leon Romanovsky <leonro@mellanox.com>
2019-02-03net/mlx5: Add XRC transport to ODP device capabilities layoutMoni Shoua1-1/+3
The device capabilities for ODP structure was missing the field for XRC transport so add it here. Signed-off-by: Moni Shoua <monis@mellanox.com> Reviewed-by: Majd Dibbiny <majd@mellanox.com> Signed-off-by: Leon Romanovsky <leonro@mellanox.com>
2019-01-29Merge branch 'devx-async' into k.o/for-nextJason Gunthorpe1-8/+26
Yishai Hadas says: Enable DEVX asynchronous query commands This series enables querying a DEVX object in an asynchronous mode. The userspace application won't block when calling the firmware and it will be able to get the response back once that it will be ready. To enable the above functionality: - DEVX asynchronous command completion FD object was introduced. - The applicable file operations were implemented to enable using it by the user application. - Query asynchronous method was added to the DEVX object, it will call the firmware asynchronously and manages the response on the given input FD. - Hot unplug support was added for the FD to work properly upon unbind/disassociate. - mlx5 core fence for asynchronous commands was implemented and used to prevent racing upon unbind/disassociate. This branch is based on mlx5-next & v5.0-rc2 due to dependencies, from git://git.kernel.org/pub/scm/linux/kernel/git/mellanox/linux * branch 'devx-async': IB/mlx5: Implement DEVX hot unplug for async command FD IB/mlx5: Implement the file ops of DEVX async command FD IB/mlx5: Introduce async DEVX obj query API IB/mlx5: Introduce MLX5_IB_OBJECT_DEVX_ASYNC_CMD_FD Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>
2019-01-24net/mlx5: Make mlx5_cmd_exec_cb() a safe APIJason Gunthorpe1-6/+26
APIs that have deferred callbacks should have some kind of cleanup function that callers can use to fence the callbacks. Otherwise things like module unloading can lead to dangling function pointers, or worse. The IB MR code is the only place that calls this function and had a really poor attempt at creating this fence. Provide a good version in the core code as future patches will add more places that need this fence. Signed-off-by: Jason Gunthorpe <jgg@mellanox.com> Signed-off-by: Yishai Hadas <yishaih@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: Leon Romanovsky <leonro@mellanox.com>
2019-01-22IB/mlx5: Manage indirection mkey upon DEVX flow for ODPYishai Hadas1-0/+1
Manage indirection mkey upon DEVX flow to support ODP. To support a page fault event on the indirection mkey it needs to be part of the device mkey radix tree. Both the creation and the deletion flows for a DEVX object which is indirection mkey were adapted to handle that. Signed-off-by: Yishai Hadas <yishaih@mellanox.com> Reviewed-by: Artemy Kovalyov <artemyko@mellanox.com> Signed-off-by: Leon Romanovsky <leonro@mellanox.com> Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>