summaryrefslogtreecommitdiff
path: root/drivers/net/ethernet
AgeCommit message (Collapse)AuthorFilesLines
2021-10-06net: stmmac: trigger PCS EEE to turn off on link downWong Vee Khee1-1/+5
The current implementation enable PCS EEE feature in the event of link up, but PCS EEE feature is not disabled on link down. This patch makes sure PCE EEE feature is disabled on link down. Fixes: 656ed8b015f1 ("net: stmmac: fix EEE init issue when paired with EEE capable PHYs") Signed-off-by: Wong Vee Khee <vee.khee.wong@linux.intel.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-02net: stmmac: dwmac-rk: Fix ethernet on rk3399 based devicesPunit Agrawal1-0/+5
Commit 2d26f6e39afb ("net: stmmac: dwmac-rk: fix unbalanced pm_runtime_enable warnings") while getting rid of a runtime PM warning ended up breaking ethernet on rk3399 based devices. By dropping an extra reference to the device, the commit ends up enabling suspend / resume of the ethernet device - which appears to be broken. While the issue with runtime pm is being investigated, partially revert commit 2d26f6e39afb to restore the network on rk3399. Fixes: 2d26f6e39afb ("net: stmmac: dwmac-rk: fix unbalanced pm_runtime_enable warnings") Suggested-by: Heiko Stuebner <heiko@sntech.de> Signed-off-by: Punit Agrawal <punitagrawal@gmail.com> Cc: Michael Riesch <michael.riesch@wolfvision.net> Tested-by: Heiko Stuebner <heiko@sntech.de> Link: https://lore.kernel.org/r/20210929135049.3426058-1-punitagrawal@gmail.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-10-02net: mscc: ocelot: fix VCAP filters remaining active after being deletedVladimir Oltean1-2/+2
When ocelot_flower.c calls ocelot_vcap_filter_add(), the filter has a given filter->id.cookie. This filter is added to the block->rules list. However, when ocelot_flower.c calls ocelot_vcap_block_find_filter_by_id() which passes the cookie as argument, the filter is never found by filter->id.cookie when searching through the block->rules list. This is unsurprising, since the filter->id.cookie is an unsigned long, but the cookie argument provided to ocelot_vcap_block_find_filter_by_id() is a signed int, and the comparison fails. Fixes: 50c6cc5b9283 ("net: mscc: ocelot: store a namespaced VCAP filter ID") Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Link: https://lore.kernel.org/r/20210930125330.2078625-1-vladimir.oltean@nxp.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-10-01net/mlx5e: Mutually exclude setting of TX-port-TS and MQPRIO in channel modeAya Levin2-0/+19
TX-port-TS hijacks the PTP traffic to a specific HW TX-queue. This conflicts with MQPRIO in channel mode, which specifies explicitly which TC accepts the packet. This patch mutually excludes the above configuration. Fixes: ec60c4581bd9 ("net/mlx5e: Support MQPRIO channel mode") Signed-off-by: Aya Levin <ayal@nvidia.com> Reviewed-by: Tariq Toukan <tariqt@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5e: Fix the presented RQ index in PTP statsLama Kayal3-3/+5
PTP-RQ counters title format contains PTP-RQ identifier, which is mistakenly not passed to sprinft(). This leads to unexpected garbage values instead. This patch fixes it. Before applying the patch: ethtool -S eth3 | grep ptp_rq ptp_rq15_packets: 0 ptp_rq8_bytes: 0 ptp_rq6_csum_complete: 0 ptp_rq14_csum_complete_tail: 0 ptp_rq3_csum_complete_tail_slow : 0 ptp_rq9_csum_unnecessary: 0 ptp_rq1_csum_unnecessary_inner: 0 ptp_rq7_csum_none: 0 ptp_rq10_xdp_drop: 0 ptp_rq9_xdp_redirect: 0 ptp_rq13_lro_packets: 0 ptp_rq12_lro_bytes: 0 ptp_rq10_ecn_mark: 0 ptp_rq9_removed_vlan_packets: 0 ptp_rq5_wqe_err: 0 ptp_rq8_mpwqe_filler_cqes: 0 ptp_rq2_mpwqe_filler_strides: 0 ptp_rq5_oversize_pkts_sw_drop: 0 ptp_rq6_buff_alloc_err: 0 ptp_rq15_cqe_compress_blks: 0 ptp_rq2_cqe_compress_pkts: 0 ptp_rq2_cache_reuse: 0 ptp_rq12_cache_full: 0 ptp_rq11_cache_empty: 256 ptp_rq12_cache_busy: 0 ptp_rq11_cache_waive: 0 ptp_rq12_congst_umr: 0 ptp_rq11_arfs_err: 0 ptp_rq9_recover: 0 After applying the patch: ethtool -S eth3 | grep ptp_rq ptp_rq0_packets: 0 ptp_rq0_bytes: 0 ptp_rq0_csum_complete: 0 ptp_rq0_csum_complete_tail: 0 ptp_rq0_csum_complete_tail_slow : 0 ptp_rq0_csum_unnecessary: 0 ptp_rq0_csum_unnecessary_inner: 0 ptp_rq0_csum_none: 0 ptp_rq0_xdp_drop: 0 ptp_rq0_xdp_redirect: 0 ptp_rq0_lro_packets: 0 ptp_rq0_lro_bytes: 0 ptp_rq0_ecn_mark: 0 ptp_rq0_removed_vlan_packets: 0 ptp_rq0_wqe_err: 0 ptp_rq0_mpwqe_filler_cqes: 0 ptp_rq0_mpwqe_filler_strides: 0 ptp_rq0_oversize_pkts_sw_drop: 0 ptp_rq0_buff_alloc_err: 0 ptp_rq0_cqe_compress_blks: 0 ptp_rq0_cqe_compress_pkts: 0 ptp_rq0_cache_reuse: 0 ptp_rq0_cache_full: 0 ptp_rq0_cache_empty: 256 ptp_rq0_cache_busy: 0 ptp_rq0_cache_waive: 0 ptp_rq0_congst_umr: 0 ptp_rq0_arfs_err: 0 ptp_rq0_recover: 0 Fixes: a28359e922c6 ("net/mlx5e: Add PTP-RX statistics") Signed-off-by: Lama Kayal <lkayal@nvidia.com> Reviewed-by: Tariq Toukan <tariqt@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5: Fix setting number of EQs of SFsShay Drory1-2/+3
When setting number of completion EQs of the SF, consider number of online CPUs. Without this consideration, when number of online cpus are less than 8, unnecessary 8 completion EQs are allocated. Fixes: c36326d38d93 ("net/mlx5: Round-Robin EQs over IRQs") Signed-off-by: Shay Drory <shayd@nvidia.com> Reviewed-by: Parav Pandit <parav@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5: Fix length of irq_index in charsShay Drory1-2/+2
The maximum irq_index can be 2047, This means irq_name should have 4 characters reserve for the irq_index. Hence, increase it to 4. Fixes: 3af26495a247 ("net/mlx5: Enlarge interrupt field in CREATE_EQ") Signed-off-by: Shay Drory <shayd@nvidia.com> Reviewed-by: Parav Pandit <parav@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5: Avoid generating event after PPS out in Real time modeAya Levin1-8/+6
When in Real-time mode, HW clock is synced with the PTP daemon. Hence driver should not re-calibrate the next pulse (via MTPPSE repetitive events mechanism). This patch arms repetitive events only in free-running mode. Fixes: 432119de33d9 ("net/mlx5: Add cyc2time HW translation mode support") Signed-off-by: Aya Levin <ayal@nvidia.com> Reviewed-by: Eran Ben Elisha <eranbe@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5: Force round second at 1PPS out start timeAya Levin1-14/+11
Allow configuration of 1PPS start time only with time-stamp representing a round second. Prior to this patch driver allowed setting of a non-round-second which is not supported by the device. Avoid unexpected behavior by restricting start-time configuration to a round-second. Fixes: 4272f9b88db9 ("net/mlx5e: Change 1PPS out scheme") Signed-off-by: Aya Levin <ayal@nvidia.com> Reviewed-by: Eran Ben Elisha <eranbe@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5: E-Switch, Fix double allocation of acl flow counterMoshe Shemesh2-5/+11
Flow counter is allocated in eswitch legacy acl setting functions without checking if already allocated by previous setting. Add a check to avoid such double allocation. Fixes: 07bab9502641 ("net/mlx5: E-Switch, Refactor eswitch ingress acl codes") Fixes: ea651a86d468 ("net/mlx5: E-Switch, Refactor eswitch egress acl codes") Signed-off-by: Moshe Shemesh <moshe@nvidia.com> Reviewed-by: Tariq Toukan <tariqt@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5e: Improve MQPRIO resiliencyTariq Toukan2-32/+80
* Add netdev->tc_to_txq rollback in case of failure in mlx5e_update_netdev_queues(). * Fix broken transition between the two modes: MQPRIO DCB mode with tc==8, and MQPRIO channel mode. * Disable MQPRIO channel mode if re-attaching with a different number of channels. * Improve code sharing. Fixes: ec60c4581bd9 ("net/mlx5e: Support MQPRIO channel mode") Signed-off-by: Tariq Toukan <tariqt@nvidia.com> Reviewed-by: Maxim Mikityanskiy <maximmi@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5e: Keep the value for maximum number of channels in-syncTariq Toukan6-34/+57
The value for maximum number of channels is first calculated based on the netdev's profile and current function resources (specifically, number of MSIX vectors, which depends among other things on the number of online cores in the system). This value is then used to calculate the netdev's number of rxqs/txqs. Once created (by alloc_etherdev_mqs), the number of netdev's rxqs/txqs is constant and we must not exceed it. To achieve this, keep the maximum number of channels in sync upon any netdevice re-attach. Use mlx5e_get_max_num_channels() for calculating the number of netdev's rxqs/txqs. After netdev is created, use mlx5e_calc_max_nch() (which coinsiders core device resources, profile, and netdev) to init or update priv->max_nch. Before this patch, the value of priv->max_nch might get out of sync, mistakenly allowing accesses to out-of-bounds objects, which would crash the system. Track the number of channels stats structures used in a separate field, as they are persistent to suspend/resume operations. All the collected stats of every channel index that ever existed should be preserved. They are reset only when struct mlx5e_priv is, in mlx5e_priv_cleanup(), which is part of the profile changing flow. There is no point anymore in blocking a profile change due to max_nch mismatch in mlx5e_netdev_change_profile(). Remove the limitation. Fixes: a1f240f18017 ("net/mlx5e: Adjust to max number of channles when re-attaching") Signed-off-by: Tariq Toukan <tariqt@nvidia.com> Reviewed-by: Aya Levin <ayal@nvidia.com> Reviewed-by: Maxim Mikityanskiy <maximmi@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-10-01net/mlx5e: IPSEC RX, enable checksum completeRaed Salem1-6/+1
Currently in Rx data path IPsec crypto offloaded packets uses csum_none flag, so checksum is handled by the stack, this naturally have some performance/cpu utilization impact on such flows. As Nvidia NIC starting from ConnectX6DX provides checksum complete value out of the box also for such flows there is no sense in taking csum_none path, furthermore the stack (xfrm) have the method to handle checksum complete corrections for such flows i.e. IPsec trailer removal and consequently checksum value adjustment. Because of the above and in addition the ConnectX6DX is the first HW which supports IPsec crypto offload then it is safe to report csum complete for IPsec offloaded traffic. Fixes: b2ac7541e377 ("net/mlx5e: IPsec: Add Connect-X IPsec Rx data path offload") Signed-off-by: Raed Salem <raeds@nvidia.com> Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
2021-09-30net: stmmac: fix EEE init issue when paired with EEE capable PHYsWong Vee Khee1-0/+4
When STMMAC is paired with Energy-Efficient Ethernet(EEE) capable PHY, and the PHY is advertising EEE by default, we need to enable EEE on the xPCS side too, instead of having user to manually trigger the enabling config via ethtool. Fixed this by adding xpcs_config_eee() call in stmmac_eee_init(). Fixes: 7617af3d1a5e ("net: pcs: Introducing support for DWC xpcs Energy Efficient Ethernet") Cc: Michael Sit Wei Hong <michael.wei.hong.sit@intel.com> Signed-off-by: Wong Vee Khee <vee.khee.wong@linux.intel.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29net: hns3: disable firmware compatible features when uninstall PFGuangbin Huang1-8/+13
Currently, the firmware compatible features are enabled in PF driver initialization process, but they are not disabled in PF driver deinitialization process and firmware keeps these features in enabled status. In this case, if load an old PF driver (for example, in VM) which not support the firmware compatible features, firmware will still send mailbox message to PF when link status changed and PF will print "un-supported mailbox message, code = 201". To fix this problem, disable these firmware compatible features in PF driver deinitialization process. Fixes: ed8fb4b262ae ("net: hns3: add link change event report") Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29net: hns3: fix always enable rx vlan filter problem after selftestGuangbin Huang1-2/+4
Currently, the rx vlan filter will always be disabled before selftest and be enabled after selftest as the rx vlan filter feature is fixed on in old device earlier than V3. However, this feature is not fixed in some new devices and it can be disabled by user. In this case, it is wrong if rx vlan filter is enabled after selftest. So fix it. Fixes: bcc26e8dc432 ("net: hns3: remove unused code in hns3_self_test()") Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29net: hns3: PF enable promisc for VF when mac table is overflowGuangbin Huang1-2/+6
If unicast mac address table is full, and user add a new mac address, the unicast promisc needs to be enabled for the new unicast mac address can be used. So does the multicast promisc. Now this feature has been implemented for PF, and VF should be implemented too. When the mac table of VF is overflow, PF will enable promisc for this VF. Fixes: 1e6e76101fd9 ("net: hns3: configure promisc mode for VF asynchronously") Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29net: hns3: fix show wrong state when add existing uc mac addressJian Shen1-10/+9
Currently, if function adds an existing unicast mac address, eventhough driver will not add this address into hardware, but it will return 0 in function hclge_add_uc_addr_common(). It will cause the state of this unicast mac address is ACTIVE in driver, but it should be in TO-ADD state. To fix this problem, function hclge_add_uc_addr_common() returns -EEXIST if mac address is existing, and delete two error log to avoid printing them all the time after this modification. Fixes: 72110b567479 ("net: hns3: return 0 and print warning when hit duplicate MAC") Signed-off-by: Jian Shen <shenjian15@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29net: hns3: fix mixed flag HCLGE_FLAG_MQPRIO_ENABLE and HCLGE_FLAG_DCB_ENABLEJian Shen2-28/+10
HCLGE_FLAG_MQPRIO_ENABLE is supposed to set when enable multiple TCs with tc mqprio, and HCLGE_FLAG_DCB_ENABLE is supposed to set when enable multiple TCs with ets. But the driver mixed the flags when updating the tm configuration. Furtherly, PFC should be available when HCLGE_FLAG_MQPRIO_ENABLE too, so remove the unnecessary limitation. Fixes: 5a5c90917467 ("net: hns3: add support for tc mqprio offload") Signed-off-by: Jian Shen <shenjian15@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29net: hns3: don't rollback when destroy mqprio failJian Shen1-6/+11
For destroy mqprio is irreversible in stack, so it's unnecessary to rollback the tc configuration when destroy mqprio failed. Otherwise, it may cause the configuration being inconsistent between driver and netstack. As the failure is usually caused by reset, and the driver will restore the configuration after reset, so it can keep the configuration being consistent between driver and hardware. Fixes: 5a5c90917467 ("net: hns3: add support for tc mqprio offload") Signed-off-by: Jian Shen <shenjian15@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29net: hns3: remove tc enable checkingJian Shen4-17/+2
Currently, in function hns3_nic_set_real_num_queue(), the driver doesn't report the queue count and offset for disabled tc. If user enables multiple TCs, but only maps user priorities to partial of them, it may cause the queue range of the unmapped TC being displayed abnormally. Fix it by removing the tc enable checking, ensure the queue count is not zero. With this change, the tc_en is useless now, so remove it. Fixes: a75a8efa00c5 ("net: hns3: Fix tc setup when netdev is first up") Signed-off-by: Jian Shen <shenjian15@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29net: hns3: do not allow call hns3_nic_net_open repeatedlyJian Shen1-0/+5
hns3_nic_net_open() is not allowed to called repeatly, but there is no checking for this. When doing device reset and setup tc concurrently, there is a small oppotunity to call hns3_nic_net_open repeatedly, and cause kernel bug by calling napi_enable twice. The calltrace information is like below: [ 3078.222780] ------------[ cut here ]------------ [ 3078.230255] kernel BUG at net/core/dev.c:6991! [ 3078.236224] Internal error: Oops - BUG: 0 [#1] PREEMPT SMP [ 3078.243431] Modules linked in: hns3 hclgevf hclge hnae3 vfio_iommu_type1 vfio_pci vfio_virqfd vfio pv680_mii(O) [ 3078.258880] CPU: 0 PID: 295 Comm: kworker/u8:5 Tainted: G O 5.14.0-rc4+ #1 [ 3078.269102] Hardware name: , BIOS KpxxxFPGA 1P B600 V181 08/12/2021 [ 3078.276801] Workqueue: hclge hclge_service_task [hclge] [ 3078.288774] pstate: 60400009 (nZCv daif +PAN -UAO -TCO BTYPE=--) [ 3078.296168] pc : napi_enable+0x80/0x84 tc qdisc sho[w 3d0e7v8 .e3t0h218 79] lr : hns3_nic_net_open+0x138/0x510 [hns3] [ 3078.314771] sp : ffff8000108abb20 [ 3078.319099] x29: ffff8000108abb20 x28: 0000000000000000 x27: ffff0820a8490300 [ 3078.329121] x26: 0000000000000001 x25: ffff08209cfc6200 x24: 0000000000000000 [ 3078.339044] x23: ffff0820a8490300 x22: ffff08209cd76000 x21: ffff0820abfe3880 [ 3078.349018] x20: 0000000000000000 x19: ffff08209cd76900 x18: 0000000000000000 [ 3078.358620] x17: 0000000000000000 x16: ffffc816e1727a50 x15: 0000ffff8f4ff930 [ 3078.368895] x14: 0000000000000000 x13: 0000000000000000 x12: 0000259e9dbeb6b4 [ 3078.377987] x11: 0096a8f7e764eb40 x10: 634615ad28d3eab5 x9 : ffffc816ad8885b8 [ 3078.387091] x8 : ffff08209cfc6fb8 x7 : ffff0820ac0da058 x6 : ffff0820a8490344 [ 3078.396356] x5 : 0000000000000140 x4 : 0000000000000003 x3 : ffff08209cd76938 [ 3078.405365] x2 : 0000000000000000 x1 : 0000000000000010 x0 : ffff0820abfe38a0 [ 3078.414657] Call trace: [ 3078.418517] napi_enable+0x80/0x84 [ 3078.424626] hns3_reset_notify_up_enet+0x78/0xd0 [hns3] [ 3078.433469] hns3_reset_notify+0x64/0x80 [hns3] [ 3078.441430] hclge_notify_client+0x68/0xb0 [hclge] [ 3078.450511] hclge_reset_rebuild+0x524/0x884 [hclge] [ 3078.458879] hclge_reset_service_task+0x3c4/0x680 [hclge] [ 3078.467470] hclge_service_task+0xb0/0xb54 [hclge] [ 3078.475675] process_one_work+0x1dc/0x48c [ 3078.481888] worker_thread+0x15c/0x464 [ 3078.487104] kthread+0x160/0x170 [ 3078.492479] ret_from_fork+0x10/0x18 [ 3078.498785] Code: c8027c81 35ffffa2 d50323bf d65f03c0 (d4210000) [ 3078.506889] ---[ end trace 8ebe0340a1b0fb44 ]--- Once hns3_nic_net_open() is excute success, the flag HNS3_NIC_STATE_DOWN will be cleared. So add checking for this flag, directly return when HNS3_NIC_STATE_DOWN is no set. Fixes: e888402789b9 ("net: hns3: call hns3_nic_net_open() while doing HNAE3_UP_CLIENT") Signed-off-by: Jian Shen <shenjian15@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-29ixgbe: Fix NULL pointer dereference in ixgbe_xdp_setupFeng Zhou2-3/+7
The ixgbe driver currently generates a NULL pointer dereference with some machine (online cpus < 63). This is due to the fact that the maximum value of num_xdp_queues is nr_cpu_ids. Code is in "ixgbe_set_rss_queues"". Here's how the problem repeats itself: Some machine (online cpus < 63), And user set num_queues to 63 through ethtool. Code is in the "ixgbe_set_channels", adapter->ring_feature[RING_F_FDIR].limit = count; It becomes 63. When user use xdp, "ixgbe_set_rss_queues" will set queues num. adapter->num_rx_queues = rss_i; adapter->num_tx_queues = rss_i; adapter->num_xdp_queues = ixgbe_xdp_queues(adapter); And rss_i's value is from f = &adapter->ring_feature[RING_F_FDIR]; rss_i = f->indices = f->limit; So "num_rx_queues" > "num_xdp_queues", when run to "ixgbe_xdp_setup", for (i = 0; i < adapter->num_rx_queues; i++) if (adapter->xdp_ring[i]->xsk_umem) It leads to panic. Call trace: [exception RIP: ixgbe_xdp+368] RIP: ffffffffc02a76a0 RSP: ffff9fe16202f8d0 RFLAGS: 00010297 RAX: 0000000000000000 RBX: 0000000000000020 RCX: 0000000000000000 RDX: 0000000000000000 RSI: 000000000000001c RDI: ffffffffa94ead90 RBP: ffff92f8f24c0c18 R8: 0000000000000000 R9: 0000000000000000 R10: ffff9fe16202f830 R11: 0000000000000000 R12: ffff92f8f24c0000 R13: ffff9fe16202fc01 R14: 000000000000000a R15: ffffffffc02a7530 ORIG_RAX: ffffffffffffffff CS: 0010 SS: 0018 7 [ffff9fe16202f8f0] dev_xdp_install at ffffffffa89fbbcc 8 [ffff9fe16202f920] dev_change_xdp_fd at ffffffffa8a08808 9 [ffff9fe16202f960] do_setlink at ffffffffa8a20235 10 [ffff9fe16202fa88] rtnl_setlink at ffffffffa8a20384 11 [ffff9fe16202fc78] rtnetlink_rcv_msg at ffffffffa8a1a8dd 12 [ffff9fe16202fcf0] netlink_rcv_skb at ffffffffa8a717eb 13 [ffff9fe16202fd40] netlink_unicast at ffffffffa8a70f88 14 [ffff9fe16202fd80] netlink_sendmsg at ffffffffa8a71319 15 [ffff9fe16202fdf0] sock_sendmsg at ffffffffa89df290 16 [ffff9fe16202fe08] __sys_sendto at ffffffffa89e19c8 17 [ffff9fe16202ff30] __x64_sys_sendto at ffffffffa89e1a64 18 [ffff9fe16202ff38] do_syscall_64 at ffffffffa84042b9 19 [ffff9fe16202ff50] entry_SYSCALL_64_after_hwframe at ffffffffa8c0008c So I fix ixgbe_max_channels so that it will not allow a setting of queues to be higher than the num_online_cpus(). And when run to ixgbe_xdp_setup, take the smaller value of num_rx_queues and num_xdp_queues. Fixes: 4a9b32f30f80 ("ixgbe: fix potential RX buffer starvation for AF_XDP") Signed-off-by: Feng Zhou <zhoufeng.zf@bytedance.com> Tested-by: Sandeep Penigalapati <sandeep.penigalapati@intel.com> Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-28net: hns3: fix hclge_dbg_dump_tm_pg() stack usageArnd Bergmann1-4/+24
This function copies strings around between multiple buffers including a large on-stack array that causes a build warning on 32-bit systems: drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_debugfs.c: In function 'hclge_dbg_dump_tm_pg': drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_debugfs.c:782:1: error: the frame size of 1424 bytes is larger than 1400 bytes [-Werror=frame-larger-than=] The function can probably be cleaned up a lot, to go back to printing directly into the output buffer, but dynamically allocating the structure is a simpler workaround for now. Fixes: 04d96139ddb3 ("net: hns3: refine function hclge_dbg_dump_tm_pri()") Signed-off-by: Arnd Bergmann <arnd@arndb.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-28net: sun: SUNVNET_COMMON should depend on INETRandy Dunlap1-0/+1
When CONFIG_INET is not set, there are failing references to IPv4 functions, so make this driver depend on INET. Fixes these build errors: sparc64-linux-ld: drivers/net/ethernet/sun/sunvnet_common.o: in function `sunvnet_start_xmit_common': sunvnet_common.c:(.text+0x1a68): undefined reference to `__icmp_send' sparc64-linux-ld: drivers/net/ethernet/sun/sunvnet_common.o: in function `sunvnet_poll_common': sunvnet_common.c:(.text+0x358c): undefined reference to `ip_send_check' Signed-off-by: Randy Dunlap <rdunlap@infradead.org> Cc: "David S. Miller" <davem@davemloft.net> Cc: Jakub Kicinski <kuba@kernel.org> Cc: Aaron Young <aaron.young@oracle.com> Cc: Rashmi Narasimhan <rashmi.narasimhan@oracle.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-28ionic: fix gathering of debug statsShannon Nelson1-9/+0
Don't print stats for which we haven't reserved space as it can cause nasty memory bashing and related bad behaviors. Fixes: aa620993b1e5 ("ionic: pull per-q stats work out of queue loops") Signed-off-by: Shannon Nelson <snelson@pensando.io> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-28Merge branch '1GbE' of git://git.kernel.org/pub/scm/linux/kernel/git/tDavid S. Miller1-7/+15
nguy/net-queue Tony Nguyen says: ==================== Intel Wired LAN Driver Updates 2021-09-27 This series contains updates to e100 driver only. Jake corrects under allocation of register buffer due to incorrect calculations and fixes buffer overrun of register dump. ==================== Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-28net: ks8851: fix link errorArnd Bergmann2-4/+10
An object file cannot be built for both loadable module and built-in use at the same time: arm-linux-gnueabi-ld: drivers/net/ethernet/micrel/ks8851_common.o: in function `ks8851_probe_common': ks8851_common.c:(.text+0xf80): undefined reference to `__this_module' Change the ks8851_common code to be a standalone module instead, and use Makefile logic to ensure this is built-in if at least one of its two users is. Fixes: 797047f875b5 ("net: ks8851: Implement Parallel bus operations") Link: https://lore.kernel.org/netdev/20210125121937.3900988-1-arnd@kernel.org/ Reviewed-by: Andrew Lunn <andrew@lunn.ch> Acked-by: Marek Vasut <marex@denx.de> Signed-off-by: Arnd Bergmann <arnd@arndb.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-27e100: fix buffer overrun in e100_get_regsJacob Keller1-6/+10
The e100_get_regs function is used to implement a simple register dump for the e100 device. The data is broken into a couple of MAC control registers, and then a series of PHY registers, followed by a memory dump buffer. The total length of the register dump is defined as (1 + E100_PHY_REGS) * sizeof(u32) + sizeof(nic->mem->dump_buf). The logic for filling in the PHY registers uses a convoluted inverted count for loop which counts from E100_PHY_REGS (0x1C) down to 0, and assigns the slots 1 + E100_PHY_REGS - i. The first loop iteration will fill in [1] and the final loop iteration will fill in [1 + 0x1C]. This is actually one more than the supposed number of PHY registers. The memory dump buffer is then filled into the space at [2 + E100_PHY_REGS] which will cause that memcpy to assign 4 bytes past the total size. The end result is that we overrun the total buffer size allocated by the kernel, which could lead to a panic or other issues due to memory corruption. It is difficult to determine the actual total number of registers here. The only 8255x datasheet I could find indicates there are 28 total MDI registers. However, we're reading 29 here, and reading them in reverse! In addition, the ethtool e100 register dump interface appears to read the first PHY register to determine if the device is in MDI or MDIx mode. This doesn't appear to be documented anywhere within the 8255x datasheet. I can only assume it must be in register 28 (the extra register we're reading here). Lets not change any of the intended meaning of what we copy here. Just extend the space by 4 bytes to account for the extra register and continue copying the data out in the same order. Change the E100_PHY_REGS value to be the correct total (29) so that the total register dump size is calculated properly. Fix the offset for where we copy the dump buffer so that it doesn't overrun the total size. Re-write the for loop to use counting up instead of the convoluted down-counting. Correct the mdio_read offset to use the 0-based register offsets, but maintain the bizarre reverse ordering so that we have the ABI expected by applications like ethtool. This requires and additional subtraction of 1. It seems a bit odd but it makes the flow of assignment into the register buffer easier to follow. Fixes: 1da177e4c3f4 ("Linux-2.6.12-rc2") Reported-by: Felicitas Hetzelt <felicitashetzelt@gmail.com> Signed-off-by: Jacob Keller <jacob.e.keller@intel.com> Tested-by: Jacob Keller <jacob.e.keller@intel.com> Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
2021-09-27e100: fix length calculation in e100_get_regs_lenJacob Keller1-1/+5
commit abf9b902059f ("e100: cleanup unneeded math") tried to simplify e100_get_regs_len and remove a double 'divide and then multiply' calculation that the e100_reg_regs_len function did. This change broke the size calculation entirely as it failed to account for the fact that the numbered registers are actually 4 bytes wide and not 1 byte. This resulted in a significant under allocation of the register buffer used by e100_get_regs. Fix this by properly multiplying the register count by u32 first before adding the size of the dump buffer. Fixes: abf9b902059f ("e100: cleanup unneeded math") Reported-by: Felicitas Hetzelt <felicitashetzelt@gmail.com> Signed-off-by: Jacob Keller <jacob.e.keller@intel.com> Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
2021-09-27Revert "ibmvnic: check failover_pending in login response"Desnes A. Nunes do Rosario1-8/+0
This reverts commit d437f5aa23aa2b7bd07cd44b839d7546cc17166f. Code has been duplicated through commit <273c29e944bd> "ibmvnic: check failover_pending in login response" Signed-off-by: Desnes A. Nunes do Rosario <desnesn@linux.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-27net: bgmac-platform: handle mac-address deferralMatthew Hagan1-0/+3
This patch is a replication of Christian Lamparter's "net: bgmac-bcma: handle deferred probe error due to mac-address" patch for the bgmac-platform driver [1]. As is the case with the bgmac-bcma driver, this change is to cover the scenario where the MAC address cannot yet be discovered due to reliance on an nvmem provider which is yet to be instantiated, resulting in a random address being assigned that has to be manually overridden. [1] https://lore.kernel.org/netdev/20210919115725.29064-1-chunkeey@gmail.com Signed-off-by: Matthew Hagan <mnhagan88@gmail.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-27net: hns: Fix spelling mistake "maped" -> "mapped"Colin Ian King1-1/+1
There is a spelling mistake in a dev_err error message. Fix it. Signed-off-by: Colin Ian King <colin.king@canonical.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-24net: enetc: fix the incorrect clearing of IF_MODE bitsVladimir Oltean1-2/+1
The enetc phylink .mac_config handler intends to clear the IFMODE field (bits 1:0) of the PM0_IF_MODE register, but incorrectly clears all the other fields instead. For normal operation, the bug was inconsequential, due to the fact that we write the PM0_IF_MODE register in two stages, first in phylink .mac_config (which incorrectly cleared out a bunch of stuff), then we update the speed and duplex to the correct values in phylink .mac_link_up. Judging by the code (not tested), it looks like maybe loopback mode was broken, since this is one of the settings in PM0_IF_MODE which is incorrectly cleared. Fixes: c76a97218dcb ("net: enetc: force the RGMII speed and duplex instead of operating in inband mode") Reported-by: Pavel Machek (CIP) <pavel@denx.de> Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-23atlantic: Fix issue in the pm resume flow.Sudarsana Reddy Kalluru1-2/+2
After fixing hibernation resume flow, another usecase was found which should be explicitly handled - resume when device is in "down" state. Invoke aq_nic_init jointly with aq_nic_start only if ndev was already up during suspend/hibernate. We still need to perform nic_deinit() if caller requests for it, to handle the freeze/resume scenarios. Fixes: 57f780f1c433 ("atlantic: Fix driver resume flow.") Signed-off-by: Sudarsana Reddy Kalluru <skalluru@marvell.com> Signed-off-by: Igor Russkikh <irusskikh@marvell.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-23net/mlx4_en: Don't allow aRFS for encapsulated packetsAya Levin1-0/+3
Driver doesn't support aRFS for encapsulated packets, return early error in such a case. Fixes: 1eb8c695bda9 ("net/mlx4_en: Add accelerated RFS support") Signed-off-by: Aya Levin <ayal@nvidia.com> Signed-off-by: Tariq Toukan <tariqt@nvidia.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-23net: mscc: ocelot: fix forwarding from BLOCKING ports remaining enabledVladimir Oltean1-3/+8
The blamed commit made the fatally incorrect assumption that ports which aren't in the FORWARDING STP state should not have packets forwarded towards them, and that is all that needs to be done. However, that logic alone permits BLOCKING ports to forward to FORWARDING ports, which of course allows packet storms to occur when there is an L2 loop. The ocelot_get_bridge_fwd_mask should not only ask "what can the bridge do for you", but "what can you do for the bridge". This way, only FORWARDING ports forward to the other FORWARDING ports from the same bridging domain, and we are still compatible with the idea of multiple bridges. Fixes: df291e54ccca ("net: ocelot: support multiple bridges") Suggested-by: Colin Foster <colin.foster@in-advantage.com> Reported-by: Colin Foster <colin.foster@in-advantage.com> Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Signed-off-by: Colin Foster <colin.foster@in-advantage.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-23net: ethernet: mtk_eth_soc: avoid creating duplicate offload entriesFelix Fietkau1-0/+3
Sometimes multiple CLS_REPLACE calls are issued for the same connection. rhashtable_insert_fast does not check for these duplicates, so multiple hardware flow entries can be created. Fix this by checking for an existing entry early Fixes: 502e84e2382d ("net: ethernet: mtk_eth_soc: add flow offloading support") Signed-off-by: Felix Fietkau <nbd@nbd.name> Signed-off-by: Ilya Lipnitskiy <ilya.lipnitskiy@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-22qed: rdma - don't wait for resources under hw error recovery flowShai Malin2-0/+16
If the HW device is during recovery, the HW resources will never return, hence we shouldn't wait for the CID (HW context ID) bitmaps to clear. This fix speeds up the error recovery flow. Fixes: 64515dc899df ("qed: Add infrastructure for error detection and recovery") Signed-off-by: Michal Kalderon <mkalderon@marvell.com> Signed-off-by: Ariel Elior <aelior@marvell.com> Signed-off-by: Shai Malin <smalin@marvell.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-20net: hns3: fix a return value error in hclge_get_reset_status()Yufeng Mo1-4/+11
hclge_get_reset_status() should return the tqp reset status. However, if the CMDQ fails, the caller will take it as tqp reset success status by mistake. Therefore, uses a parameters to get the tqp reset status instead. Fixes: 46a3df9f9718 ("net: hns3: Add HNS3 Acceleration Engine & Compatibility Layer Support") Signed-off-by: Yufeng Mo <moyufeng@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-20net: hns3: check vlan id before using itliaoguojia1-0/+3
The input parameters may not be reliable, so check the vlan id before using it, otherwise may set wrong vlan id into hardware. Fixes: dc8131d846d4 ("net: hns3: Fix for packet loss due wrong filter config in VLAN tbls") Signed-off-by: liaoguojia <liaoguojia@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-20net: hns3: check queue id range before usingYufeng Mo1-0/+8
The input parameters may not be reliable. Before using the queue id, we should check this parameter. Otherwise, memory overwriting may occur. Fixes: d34100184685 ("net: hns3: refactor the mailbox message between PF and VF") Signed-off-by: Yufeng Mo <moyufeng@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-20net: hns3: fix misuse vf id and vport id in some logsJiaran Zhang4-10/+12
vport_id include PF and VFs, vport_id = 0 means PF, other values mean VFs. So the actual vf id is equal to vport_id minus 1. Some VF print logs are actually vport, and logs of vf id actually use vport id, so this patch fixes them. Fixes: ac887be5b0fe ("net: hns3: change print level of RAS error log from warning to error") Fixes: adcf738b804b ("net: hns3: cleanup some print format warning") Signed-off-by: Jiaran Zhang <zhangjiaran@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-20net: hns3: fix inconsistent vf id printJian Shen1-2/+5
The vf id from ethtool is added 1 before configured to driver. So it's necessary to minus 1 when printing it, in order to keep consistent with user's configuration. Fixes: dd74f815dd41 ("net: hns3: Add support for rule add/delete for flow director") Signed-off-by: Jian Shen <shenjian15@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-20net: hns3: fix change RSS 'hfunc' ineffective issueJian Shen2-33/+64
When user change rss 'hfunc' without set rss 'hkey' by ethtool -X command, the driver will ignore the 'hfunc' for the hkey is NULL. It's unreasonable. So fix it. Fixes: 46a3df9f9718 ("net: hns3: Add HNS3 Acceleration Engine & Compatibility Layer Support") Fixes: 374ad291762a ("net: hns3: Add RSS general configuration support for VF") Signed-off-by: Jian Shen <shenjian15@huawei.com> Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-20bnxt_en: Fix TX timeout when TX ring size is set to the smallestMichael Chan3-5/+10
The smallest TX ring size we support must fit a TX SKB with MAX_SKB_FRAGS + 1. Because the first TX BD for a packet is always a long TX BD, we need an extra TX BD to fit this packet. Define BNXT_MIN_TX_DESC_CNT with this value to make this more clear. The current code uses a minimum that is off by 1. Fix it using this constant. The tx_wake_thresh to determine when to wake up the TX queue is half the ring size but we must have at least BNXT_MIN_TX_DESC_CNT for the next packet which may have maximum fragments. So the comparison of the available TX BDs with tx_wake_thresh should be >= instead of > in the current code. Otherwise, at the smallest ring size, we will never wake up the TX queue and will cause TX timeout. Fixes: c0c050c58d84 ("bnxt_en: New Broadcom ethernet driver.") Reviewed-by: Pavan Chebbi <pavan.chebbi@broadcom.com> Signed-off-by: Michael Chan <michael.chan@broadocm.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-19net/mlx4_en: Resolve bad operstate valueLama Kayal2-19/+29
Any link state change that's done prior to net device registration isn't reflected on the state, thus the operational state is left obsolete, with 'UNKNOWN' status. To resolve the issue, query link state from FW upon open operations to ensure operational state is updated. Fixes: c27a02cd94d6 ("mlx4_en: Add driver for Mellanox ConnectX 10GbE NIC") Signed-off-by: Lama Kayal <lkayal@nvidia.com> Signed-off-by: Tariq Toukan <tariqt@nvidia.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-19net: bgmac-bcma: handle deferred probe error due to mac-addressChristian Lamparter1-0/+2
Due to the inclusion of nvmem handling into the mac-address getter function of_get_mac_address() by commit d01f449c008a ("of_net: add NVMEM support to of_get_mac_address") it is now possible to get a -EPROBE_DEFER return code. Which did cause bgmac to assign a random ethernet address. This exact issue happened on my Meraki MR32. The nvmem provider is an EEPROM (at24c64) which gets instantiated once the module driver is loaded... This happens once the filesystem becomes available. With this patch, bgmac_probe() will propagate the -EPROBE_DEFER error. Then the driver subsystem will reschedule the probe at a later time. Cc: Petr Štetiar <ynezz@true.cz> Cc: Michael Walle <michael@walle.cc> Fixes: d01f449c008a ("of_net: add NVMEM support to of_get_mac_address") Signed-off-by: Christian Lamparter <chunkeey@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-19net: freescale: drop unneeded MODULE_ALIASKrzysztof Kozlowski1-1/+0
The MODULE_DEVICE_TABLE already creates proper alias for platform driver. Having another MODULE_ALIAS causes the alias to be duplicated. Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2021-09-19net: mscc: ocelot: remove buggy duplicate write to DEV_CLOCK_CFGColin Foster1-6/+0
When updating ocelot to use phylink, a second write to DEV_CLOCK_CFG was mistakenly left in. It used the variable "speed" which, previously, would would have been assigned a value of OCELOT_SPEED_1000. In phylink the variable is be SPEED_1000, which is invalid for the DEV_CLOCK_LINK_SPEED macro. Removing it as unnecessary and buggy. Fixes: e6e12df625f2 ("net: mscc: ocelot: convert to phylink") Signed-off-by: Colin Foster <colin.foster@in-advantage.com> Reviewed-by: Vladimir Oltean <vladimir.oltean@nxp.com> Signed-off-by: David S. Miller <davem@davemloft.net>