Age | Commit message (Collapse) | Author | Files | Lines | |
---|---|---|---|---|---|
2015-12-12 | iio: ina2xx: provide a sysfs parameter to allow async readout of the ADCs | Marc Titinger | 1 | -9/+45 | |
This can lead to repeated or skipped samples depending on the clock beat between the capture thread and the chip sampling clock, but will also spare reading/waiting for the Capture Ready Flag and improve the available i2c bandwidth for reading measurements. Output of iio_info: ...snip... 4 device-specific attributes found: attr 0: in_oversampling_ratio value: 4 attr 1: in_allow_async_readout value: 0 attr 2: integration_time_available value: 140 204 332 588 1100 2116... attr 3: in_sampling_frequency value: 114 Signed-off-by: Marc Titinger <mtitinger@baylibre.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org> | |||||
2015-12-12 | iio: ina2xx: add support for TI INA2xx Power Monitors | Marc Titinger | 1 | -0/+668 | |
in SOFTWARE buffer mode, a kthread will capture the active scan_elements into a kfifo, then compute the remaining time until the next capture tick and do an active wait (udelay). This will produce a stream of up to fours channels plus a 64bits timestamps (ns). Tested with ina226, on BeagleBoneBlack. Datasheet: http://www.ti.com/lit/gpn/ina226 Signed-off-by: Marc Titinger <mtitinger@baylibre.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org> |