diff options
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 31 |
1 files changed, 20 insertions, 11 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 6509c61b9648..5ae0524bed19 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -107,6 +107,9 @@ struct cpufreq_cooling_device { static DEFINE_IDR(cpufreq_idr); static DEFINE_MUTEX(cooling_cpufreq_lock); +static unsigned int cpufreq_dev_count; + +static DEFINE_MUTEX(cooling_list_lock); static LIST_HEAD(cpufreq_dev_list); /** @@ -185,14 +188,14 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq) { struct cpufreq_cooling_device *cpufreq_dev; - mutex_lock(&cooling_cpufreq_lock); + mutex_lock(&cooling_list_lock); list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) { - mutex_unlock(&cooling_cpufreq_lock); + mutex_unlock(&cooling_list_lock); return get_level(cpufreq_dev, freq); } } - mutex_unlock(&cooling_cpufreq_lock); + mutex_unlock(&cooling_list_lock); pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu); return THERMAL_CSTATE_INVALID; @@ -221,7 +224,7 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, switch (event) { case CPUFREQ_ADJUST: - mutex_lock(&cooling_cpufreq_lock); + mutex_lock(&cooling_list_lock); list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { if (!cpumask_test_cpu(policy->cpu, &cpufreq_dev->allowed_cpus)) @@ -233,7 +236,7 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, cpufreq_verify_within_limits(policy, 0, max_freq); } - mutex_unlock(&cooling_cpufreq_lock); + mutex_unlock(&cooling_list_lock); break; default: return NOTIFY_DONE; @@ -866,12 +869,14 @@ __cpufreq_cooling_register(struct device_node *np, mutex_lock(&cooling_cpufreq_lock); + mutex_lock(&cooling_list_lock); + list_add(&cpufreq_dev->node, &cpufreq_dev_list); + mutex_unlock(&cooling_list_lock); + /* Register the notifier for first cpufreq cooling device */ - if (list_empty(&cpufreq_dev_list)) + if (!cpufreq_dev_count++) cpufreq_register_notifier(&thermal_cpufreq_notifier_block, CPUFREQ_POLICY_NOTIFIER); - list_add(&cpufreq_dev->node, &cpufreq_dev_list); - mutex_unlock(&cooling_cpufreq_lock); return cool_dev; @@ -1013,13 +1018,17 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) return; cpufreq_dev = cdev->devdata; - mutex_lock(&cooling_cpufreq_lock); - list_del(&cpufreq_dev->node); /* Unregister the notifier for the last cpufreq cooling device */ - if (list_empty(&cpufreq_dev_list)) + mutex_lock(&cooling_cpufreq_lock); + if (!--cpufreq_dev_count) cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block, CPUFREQ_POLICY_NOTIFIER); + + mutex_lock(&cooling_list_lock); + list_del(&cpufreq_dev->node); + mutex_unlock(&cooling_list_lock); + mutex_unlock(&cooling_cpufreq_lock); thermal_cooling_device_unregister(cpufreq_dev->cool_dev); |