summaryrefslogtreecommitdiff
path: root/drivers
diff options
context:
space:
mode:
Diffstat (limited to 'drivers')
-rw-r--r--drivers/thermal/cpu_cooling.c31
1 files changed, 20 insertions, 11 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 6509c61b9648..5ae0524bed19 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -107,6 +107,9 @@ struct cpufreq_cooling_device {
static DEFINE_IDR(cpufreq_idr);
static DEFINE_MUTEX(cooling_cpufreq_lock);
+static unsigned int cpufreq_dev_count;
+
+static DEFINE_MUTEX(cooling_list_lock);
static LIST_HEAD(cpufreq_dev_list);
/**
@@ -185,14 +188,14 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
{
struct cpufreq_cooling_device *cpufreq_dev;
- mutex_lock(&cooling_cpufreq_lock);
+ mutex_lock(&cooling_list_lock);
list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) {
- mutex_unlock(&cooling_cpufreq_lock);
+ mutex_unlock(&cooling_list_lock);
return get_level(cpufreq_dev, freq);
}
}
- mutex_unlock(&cooling_cpufreq_lock);
+ mutex_unlock(&cooling_list_lock);
pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu);
return THERMAL_CSTATE_INVALID;
@@ -221,7 +224,7 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
switch (event) {
case CPUFREQ_ADJUST:
- mutex_lock(&cooling_cpufreq_lock);
+ mutex_lock(&cooling_list_lock);
list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
if (!cpumask_test_cpu(policy->cpu,
&cpufreq_dev->allowed_cpus))
@@ -233,7 +236,7 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
cpufreq_verify_within_limits(policy, 0,
max_freq);
}
- mutex_unlock(&cooling_cpufreq_lock);
+ mutex_unlock(&cooling_list_lock);
break;
default:
return NOTIFY_DONE;
@@ -866,12 +869,14 @@ __cpufreq_cooling_register(struct device_node *np,
mutex_lock(&cooling_cpufreq_lock);
+ mutex_lock(&cooling_list_lock);
+ list_add(&cpufreq_dev->node, &cpufreq_dev_list);
+ mutex_unlock(&cooling_list_lock);
+
/* Register the notifier for first cpufreq cooling device */
- if (list_empty(&cpufreq_dev_list))
+ if (!cpufreq_dev_count++)
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
- list_add(&cpufreq_dev->node, &cpufreq_dev_list);
-
mutex_unlock(&cooling_cpufreq_lock);
return cool_dev;
@@ -1013,13 +1018,17 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
return;
cpufreq_dev = cdev->devdata;
- mutex_lock(&cooling_cpufreq_lock);
- list_del(&cpufreq_dev->node);
/* Unregister the notifier for the last cpufreq cooling device */
- if (list_empty(&cpufreq_dev_list))
+ mutex_lock(&cooling_cpufreq_lock);
+ if (!--cpufreq_dev_count)
cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
+
+ mutex_lock(&cooling_list_lock);
+ list_del(&cpufreq_dev->node);
+ mutex_unlock(&cooling_list_lock);
+
mutex_unlock(&cooling_cpufreq_lock);
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);