-rw-r--r--Documentation/ABI/testing/sysfs-class-thermal2
-rw-r--r--Documentation/devicetree/bindings/thermal/exynos-thermal.txt106
-rw-r--r--Documentation/devicetree/bindings/thermal/qcom-lmh.yaml1
-rw-r--r--Documentation/devicetree/bindings/thermal/qcom-tsens.yaml1
-rw-r--r--Documentation/devicetree/bindings/thermal/samsung,exynos-thermal.yaml184
-rw-r--r--Documentation/driver-api/thermal/index.rst1
-rw-r--r--Documentation/driver-api/thermal/intel_dptf.rst272
-rw-r--r--Documentation/x86/index.rst1
-rw-r--r--Documentation/x86/intel-hfi.rst72
9 files changed, 533 insertions, 107 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-thermal b/Documentation/ABI/testing/sysfs-class-thermal
index 2c52bb1f864c..8eee37982b2a 100644
--- a/Documentation/ABI/testing/sysfs-class-thermal
+++ b/Documentation/ABI/testing/sysfs-class-thermal
@@ -203,7 +203,7 @@ Description:
- for generic ACPI: should be "Fan", "Processor" or "LCD"
- for memory controller device on intel_menlow platform:
- should be "Memory controller".
+ should be "Memory controller".
RO, Required
diff --git a/Documentation/devicetree/bindings/thermal/exynos-thermal.txt b/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
deleted file mode 100644
index 33004ce7e5df..000000000000
--- a/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
+++ /dev/null
@@ -1,106 +0,0 @@
-* Exynos Thermal Management Unit (TMU)
-
-** Required properties:
-
-- compatible : One of the following:
- "samsung,exynos3250-tmu"
- "samsung,exynos4412-tmu"
- "samsung,exynos4210-tmu"
- "samsung,exynos5250-tmu"
- "samsung,exynos5260-tmu"
- "samsung,exynos5420-tmu" for TMU channel 0, 1 on Exynos5420
- "samsung,exynos5420-tmu-ext-triminfo" for TMU channels 2, 3 and 4
- Exynos5420 (Must pass triminfo base and triminfo clock)
- "samsung,exynos5433-tmu"
- "samsung,exynos7-tmu"
-- reg : Address range of the thermal registers. For soc's which has multiple
- instances of TMU and some registers are shared across all TMU's like
- interrupt related then 2 set of register has to supplied. First set
- belongs to register set of TMU instance and second set belongs to
- registers shared with the TMU instance.
-
- NOTE: On Exynos5420, the TRIMINFO register is misplaced for TMU
- channels 2, 3 and 4
- Use "samsung,exynos5420-tmu-ext-triminfo" in cases, there is a misplaced
- register, also provide clock to access that base.
-
- TRIMINFO at 0x1006c000 contains data for TMU channel 3
- TRIMINFO at 0x100a0000 contains data for TMU channel 4
- TRIMINFO at 0x10068000 contains data for TMU channel 2
-
-- interrupts : Should contain interrupt for thermal system
-- clocks : The main clocks for TMU device
- -- 1. operational clock for TMU channel
- -- 2. optional clock to access the shared registers of TMU channel
- -- 3. optional special clock for functional operation
-- clock-names : Thermal system clock name
- -- "tmu_apbif" operational clock for current TMU channel
- -- "tmu_triminfo_apbif" clock to access the shared triminfo register
- for current TMU channel
- -- "tmu_sclk" clock for functional operation of the current TMU
- channel
-
-The Exynos TMU supports generating interrupts when reaching given
-temperature thresholds. Number of supported thermal trip points depends
-on the SoC (only first trip points defined in DT will be configured):
- - most of SoC: 4
- - samsung,exynos5433-tmu: 8
- - samsung,exynos7-tmu: 8
-
-** Optional properties:
-
-- vtmu-supply: This entry is optional and provides the regulator node supplying
- voltage to TMU. If needed this entry can be placed inside
- board/platform specific dts file.
-
-Example 1):
-
- tmu@100c0000 {
- compatible = "samsung,exynos4412-tmu";
- interrupt-parent = <&combiner>;
- reg = <0x100C0000 0x100>;
- interrupts = <2 4>;
- clocks = <&clock 383>;
- clock-names = "tmu_apbif";
- vtmu-supply = <&tmu_regulator_node>;
- #thermal-sensor-cells = <0>;
- };
-
-Example 2): (In case of Exynos5420 "with misplaced TRIMINFO register")
- tmu_cpu2: tmu@10068000 {
- compatible = "samsung,exynos5420-tmu-ext-triminfo";
- reg = <0x10068000 0x100>, <0x1006c000 0x4>;
- interrupts = <0 184 0>;
- clocks = <&clock 318>, <&clock 318>;
- clock-names = "tmu_apbif", "tmu_triminfo_apbif";
- #thermal-sensor-cells = <0>;
- };
-
- tmu_cpu3: tmu@1006c000 {
- compatible = "samsung,exynos5420-tmu-ext-triminfo";
- reg = <0x1006c000 0x100>, <0x100a0000 0x4>;
- interrupts = <0 185 0>;
- clocks = <&clock 318>, <&clock 319>;
- clock-names = "tmu_apbif", "tmu_triminfo_apbif";
- #thermal-sensor-cells = <0>;
- };
-
- tmu_gpu: tmu@100a0000 {
- compatible = "samsung,exynos5420-tmu-ext-triminfo";
- reg = <0x100a0000 0x100>, <0x10068000 0x4>;
- interrupts = <0 215 0>;
- clocks = <&clock 319>, <&clock 318>;
- clock-names = "tmu_apbif", "tmu_triminfo_apbif";
- #thermal-sensor-cells = <0>;
- };
-
-Note: For multi-instance tmu each instance should have an alias correctly
-numbered in "aliases" node.
-
-Example:
-
-aliases {
- tmuctrl0 = &tmuctrl_0;
- tmuctrl1 = &tmuctrl_1;
- tmuctrl2 = &tmuctrl_2;
-};
diff --git a/Documentation/devicetree/bindings/thermal/qcom-lmh.yaml b/Documentation/devicetree/bindings/thermal/qcom-lmh.yaml
index 289e9a845600..a9b7388ca9ac 100644
--- a/Documentation/devicetree/bindings/thermal/qcom-lmh.yaml
+++ b/Documentation/devicetree/bindings/thermal/qcom-lmh.yaml
@@ -19,6 +19,7 @@ properties:
compatible:
enum:
- qcom,sdm845-lmh
+ - qcom,sm8150-lmh
reg:
items:
diff --git a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
index d3b9e9b600a2..b6406bcc683f 100644
--- a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
+++ b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
@@ -43,6 +43,7 @@ properties:
- description: v2 of TSENS
items:
- enum:
+ - qcom,msm8953-tsens
- qcom,msm8996-tsens
- qcom,msm8998-tsens
- qcom,sc7180-tsens
diff --git a/Documentation/devicetree/bindings/thermal/samsung,exynos-thermal.yaml b/Documentation/devicetree/bindings/thermal/samsung,exynos-thermal.yaml
new file mode 100644
index 000000000000..17129f75d962
--- /dev/null
+++ b/Documentation/devicetree/bindings/thermal/samsung,exynos-thermal.yaml
@@ -0,0 +1,184 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/thermal/samsung,exynos-thermal.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Samsung Exynos SoC Thermal Management Unit (TMU)
+
+maintainers:
+ - Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com>
+
+description: |
+ For multi-instance tmu each instance should have an alias correctly numbered
+ in "aliases" node.
+
+properties:
+ compatible:
+ enum:
+ - samsung,exynos3250-tmu
+ - samsung,exynos4412-tmu
+ - samsung,exynos4210-tmu
+ - samsung,exynos5250-tmu
+ - samsung,exynos5260-tmu
+ # For TMU channel 0, 1 on Exynos5420:
+ - samsung,exynos5420-tmu
+ # For TMU channels 2, 3 and 4 of Exynos5420:
+ - samsung,exynos5420-tmu-ext-triminfo
+ - samsung,exynos5433-tmu
+ - samsung,exynos7-tmu
+
+ clocks:
+ minItems: 1
+ maxItems: 3
+
+ clock-names:
+ minItems: 1
+ maxItems: 3
+
+ interrupts:
+ description: |
+ The Exynos TMU supports generating interrupts when reaching given
+ temperature thresholds. Number of supported thermal trip points depends
+ on the SoC (only first trip points defined in DT will be configured)::
+ - most of SoC: 4
+ - samsung,exynos5433-tmu: 8
+ - samsung,exynos7-tmu: 8
+ maxItems: 1
+
+ reg:
+ items:
+ - description: TMU instance registers.
+ - description: |
+ Shared TMU registers.
+
+ Note:: On Exynos5420, the TRIMINFO register is misplaced for TMU
+ channels 2, 3 and 4 Use "samsung,exynos5420-tmu-ext-triminfo" in
+ cases, there is a misplaced register, also provide clock to access
+ that base.
+ TRIMINFO at 0x1006c000 contains data for TMU channel 3
+ TRIMINFO at 0x100a0000 contains data for TMU channel 4
+ TRIMINFO at 0x10068000 contains data for TMU channel 2
+ minItems: 1
+
+ '#thermal-sensor-cells': true
+
+ vtmu-supply:
+ description: The regulator node supplying voltage to TMU.
+
+required:
+ - compatible
+ - clocks
+ - clock-names
+ - interrupts
+ - reg
+
+allOf:
+ - $ref: /schemas/thermal/thermal-sensor.yaml
+ - if:
+ properties:
+ compatible:
+ contains:
+ const: samsung,exynos5420-tmu-ext-triminfo
+ then:
+ properties:
+ clocks:
+ items:
+ - description:
+ Operational clock for TMU channel.
+ - description:
+ Optional clock to access the shared registers (e.g. TRIMINFO) of TMU
+ channel.
+ clock-names:
+ items:
+ - const: tmu_apbif
+ - const: tmu_triminfo_apbif
+ reg:
+ minItems: 2
+ maxItems: 2
+ - if:
+ properties:
+ compatible:
+ contains:
+ enum:
+ - samsung,exynos5433-tmu
+ - samsung,exynos7-tmu
+ then:
+ properties:
+ clocks:
+ items:
+ - description:
+ Operational clock for TMU channel.
+ - description:
+ Optional special clock for functional operation of TMU channel.
+ clock-names:
+ items:
+ - const: tmu_apbif
+ - const: tmu_sclk
+ reg:
+ minItems: 1
+ maxItems: 1
+
+ - if:
+ properties:
+ compatible:
+ contains:
+ enum:
+ - samsung,exynos3250-tmu
+ - samsung,exynos4412-tmu
+ - samsung,exynos4210-tmu
+ - samsung,exynos5250-tmu
+ - samsung,exynos5260-tmu
+ - samsung,exynos5420-tmu
+ then:
+ properties:
+ clocks:
+ minItems: 1
+ maxItems: 1
+ reg:
+ minItems: 1
+ maxItems: 1
+
+additionalProperties: false
+
+examples:
+ - |
+ #include <dt-bindings/clock/exynos4.h>
+
+ tmu@100c0000 {
+ compatible = "samsung,exynos4412-tmu";
+ reg = <0x100C0000 0x100>;
+ interrupt-parent = <&combiner>;
+ interrupts = <2 4>;
+ #thermal-sensor-cells = <0>;
+ clocks = <&clock CLK_TMU_APBIF>;
+ clock-names = "tmu_apbif";
+ vtmu-supply = <&ldo10_reg>;
+ };
+
+ - |
+ #include <dt-bindings/interrupt-controller/arm-gic.h>
+
+ tmu@10068000 {
+ compatible = "samsung,exynos5420-tmu-ext-triminfo";
+ reg = <0x10068000 0x100>, <0x1006c000 0x4>;
+ interrupts = <GIC_SPI 184 IRQ_TYPE_LEVEL_HIGH>;
+ #thermal-sensor-cells = <0>;
+ clocks = <&clock 318>, <&clock 318>; /* CLK_TMU */
+ clock-names = "tmu_apbif", "tmu_triminfo_apbif";
+ vtmu-supply = <&ldo7_reg>;
+ };
+
+ - |
+ #include <dt-bindings/interrupt-controller/arm-gic.h>
+
+ tmu@10060000 {
+ compatible = "samsung,exynos5433-tmu";
+ reg = <0x10060000 0x200>;
+ interrupts = <GIC_SPI 95 IRQ_TYPE_LEVEL_HIGH>;
+ #thermal-sensor-cells = <0>;
+ clocks = <&cmu_peris 3>, /* CLK_PCLK_TMU0_APBIF */
+ <&cmu_peris 35>; /* CLK_SCLK_TMU0 */
+ clock-names = "tmu_apbif", "tmu_sclk";
+ vtmu-supply = <&ldo3_reg>;
+ };
diff --git a/Documentation/driver-api/thermal/index.rst b/Documentation/driver-api/thermal/index.rst
index 4cb0b9b6bfb8..030306ffa408 100644
--- a/Documentation/driver-api/thermal/index.rst
+++ b/Documentation/driver-api/thermal/index.rst
@@ -17,3 +17,4 @@ Thermal
intel_powerclamp
nouveau_thermal
x86_pkg_temperature_thermal
+ intel_dptf
diff --git a/Documentation/driver-api/thermal/intel_dptf.rst b/Documentation/driver-api/thermal/intel_dptf.rst
new file mode 100644
index 000000000000..96668dca753a
--- /dev/null
+++ b/Documentation/driver-api/thermal/intel_dptf.rst
@@ -0,0 +1,272 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+===============================================================
+Intel(R) Dynamic Platform and Thermal Framework Sysfs Interface
+===============================================================
+
+:Copyright: |copy| 2022 Intel Corporation
+
+:Author: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
+
+Introduction
+------------
+
+Intel(R) Dynamic Platform and Thermal Framework (DPTF) is a platform
+level hardware/software solution for power and thermal management.
+
+As a container for multiple power/thermal technologies, DPTF provides
+a coordinated approach for different policies to effect the hardware
+state of a system.
+
+Since it is a platform level framework, this has several components.
+Some parts of the technology is implemented in the firmware and uses
+ACPI and PCI devices to expose various features for monitoring and
+control. Linux has a set of kernel drivers exposing hardware interface
+to user space. This allows user space thermal solutions like
+"Linux Thermal Daemon" to read platform specific thermal and power
+tables to deliver adequate performance while keeping the system under
+thermal limits.
+
+DPTF ACPI Drivers interface
+----------------------------
+
+:file:`/sys/bus/platform/devices/<N>/uuids`, where <N>
+=INT3400|INTC1040|INTC1041|INTC10A0
+
+``available_uuids`` (RO)
+ A set of UUIDs strings presenting available policies
+ which should be notified to the firmware when the
+ user space can support those policies.
+
+ UUID strings:
+
+ "42A441D6-AE6A-462b-A84B-4A8CE79027D3" : Passive 1
+
+ "3A95C389-E4B8-4629-A526-C52C88626BAE" : Active
+
+ "97C68AE7-15FA-499c-B8C9-5DA81D606E0A" : Critical
+
+ "63BE270F-1C11-48FD-A6F7-3AF253FF3E2D" : Adaptive performance
+
+ "5349962F-71E6-431D-9AE8-0A635B710AEE" : Emergency call
+
+ "9E04115A-AE87-4D1C-9500-0F3E340BFE75" : Passive 2
+
+ "F5A35014-C209-46A4-993A-EB56DE7530A1" : Power Boss
+
+ "6ED722A7-9240-48A5-B479-31EEF723D7CF" : Virtual Sensor
+
+ "16CAF1B7-DD38-40ED-B1C1-1B8A1913D531" : Cooling mode
+
+ "BE84BABF-C4D4-403D-B495-3128FD44dAC1" : HDC
+
+``current_uuid`` (RW)
+ User space can write strings from available UUIDs, one at a
+ time.
+
+:file:`/sys/bus/platform/devices/<N>/`, where <N>
+=INT3400|INTC1040|INTC1041|INTC10A0
+
+``imok`` (WO)
+ User space daemon write 1 to respond to firmware event
+ for sending keep alive notification. User space receives
+ THERMAL_EVENT_KEEP_ALIVE kobject uevent notification when
+ firmware calls for user space to respond with imok ACPI
+ method.
+
+``odvp*`` (RO)
+ Firmware thermal status variable values. Thermal tables
+ calls for different processing based on these variable
+ values.
+
+``data_vault`` (RO)
+ Binary thermal table. Refer to
+ https:/github.com/intel/thermal_daemon for decoding
+ thermal table.
+
+
+ACPI Thermal Relationship table interface
+------------------------------------------
+
+:file:`/dev/acpi_thermal_rel`
+
+ This device provides IOCTL interface to read standard ACPI
+ thermal relationship tables via ACPI methods _TRT and _ART.
+ These IOCTLs are defined in
+ drivers/thermal/intel/int340x_thermal/acpi_thermal_rel.h
+
+ IOCTLs:
+
+ ACPI_THERMAL_GET_TRT_LEN: Get length of TRT table
+
+ ACPI_THERMAL_GET_ART_LEN: Get length of ART table
+
+ ACPI_THERMAL_GET_TRT_COUNT: Number of records in TRT table
+
+ ACPI_THERMAL_GET_ART_COUNT: Number of records in ART table
+
+ ACPI_THERMAL_GET_TRT: Read binary TRT table, length to read is
+ provided via argument to ioctl().
+
+ ACPI_THERMAL_GET_ART: Read binary ART table, length to read is
+ provided via argument to ioctl().
+
+DPTF ACPI Sensor drivers
+-------------------------
+
+DPTF Sensor drivers are presented as standard thermal sysfs thermal_zone.
+
+
+DPTF ACPI Cooling drivers
+--------------------------
+
+DPTF cooling drivers are presented as standard thermal sysfs cooling_device.
+
+
+DPTF Processor thermal PCI Driver interface
+--------------------------------------------
+
+:file:`/sys/bus/pci/devices/0000\:00\:04.0/power_limits/`
+
+Refer to Documentation/power/powercap/powercap.rst for powercap
+ABI.
+
+``power_limit_0_max_uw`` (RO)
+ Maximum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
+
+``power_limit_0_step_uw`` (RO)
+ Power limit increment/decrements for Intel RAPL constraint 0 power limit
+
+``power_limit_0_min_uw`` (RO)
+ Minimum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
+
+``power_limit_0_tmin_us`` (RO)
+ Minimum powercap sysfs constraint_0_time_window_us for Intel RAPL
+
+``power_limit_0_tmax_us`` (RO)
+ Maximum powercap sysfs constraint_0_time_window_us for Intel RAPL
+
+``power_limit_1_max_uw`` (RO)
+ Maximum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
+
+``power_limit_1_step_uw`` (RO)
+ Power limit increment/decrements for Intel RAPL constraint 1 power limit
+
+``power_limit_1_min_uw`` (RO)
+ Minimum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
+
+``power_limit_1_tmin_us`` (RO)
+ Minimum powercap sysfs constraint_1_time_window_us for Intel RAPL
+
+``power_limit_1_tmax_us`` (RO)
+ Maximum powercap sysfs constraint_1_time_window_us for Intel RAPL
+
+:file:`/sys/bus/pci/devices/0000\:00\:04.0/`
+
+``tcc_offset_degree_celsius`` (RW)
+ TCC offset from the critical temperature where hardware will throttle
+ CPU.
+
+:file:`/sys/bus/pci/devices/0000\:00\:04.0/workload_request`
+
+``workload_available_types`` (RO)
+ Available workload types. User space can specify one of the workload type
+ it is currently executing via workload_type. For example: idle, bursty,
+ sustained etc.
+
+``workload_type`` (RW)
+ User space can specify any one of the available workload type using
+ this interface.
+
+DPTF Processor thermal RFIM interface
+--------------------------------------------
+
+RFIM interface allows adjustment of FIVR (Fully Integrated Voltage Regulator)
+and DDR (Double Data Rate)frequencies to avoid RF interference with WiFi and 5G.
+
+Switching voltage regulators (VR) generate radiated EMI or RFI at the
+fundamental frequency and its harmonics. Some harmonics may interfere
+with very sensitive wireless receivers such as Wi-Fi and cellular that
+are integrated into host systems like notebook PCs. One of mitigation
+methods is requesting SOC integrated VR (IVR) switching frequency to a
+small % and shift away the switching noise harmonic interference from
+radio channels. OEM or ODMs can use the driver to control SOC IVR
+operation within the range where it does not impact IVR performance.
+
+DRAM devices of DDR IO interface and their power plane can generate EMI
+at the data rates. Similar to IVR control mechanism, Intel offers a
+mechanism by which DDR data rates can be changed if several conditions
+are met: there is strong RFI interference because of DDR; CPU power
+management has no other restriction in changing DDR data rates;
+PC ODMs enable this feature (real time DDR RFI Mitigation referred to as
+DDR-RFIM) for Wi-Fi from BIOS.
+
+
+FIVR attributes
+
+:file:`/sys/bus/pci/devices/0000\:00\:04.0/fivr/`
+
+``vco_ref_code_lo`` (RW)
+ The VCO reference code is an 11-bit field and controls the FIVR
+ switching frequency. This is the 3-bit LSB field.
+
+``vco_ref_code_hi`` (RW)
+ The VCO reference code is an 11-bit field and controls the FIVR
+ switching frequency. This is the 8-bit MSB field.
+
+``spread_spectrum_pct`` (RW)
+ Set the FIVR spread spectrum clocking percentage
+
+``spread_spectrum_clk_enable`` (RW)
+ Enable/disable of the FIVR spread spectrum clocking feature
+
+``rfi_vco_ref_code`` (RW)
+ This field is a read only status register which reflects the
+ current FIVR switching frequency
+
+``fivr_fffc_rev`` (RW)
+ This field indicated the revision of the FIVR HW.
+
+
+DVFS attributes
+
+:file:`/sys/bus/pci/devices/0000\:00\:04.0/dvfs/`
+
+``rfi_restriction_run_busy`` (RW)
+ Request the restriction of specific DDR data rate and set this
+ value 1. Self reset to 0 after operation.
+
+``rfi_restriction_err_code`` (RW)
+ 0 :Request is accepted, 1:Feature disabled,
+ 2: the request restricts more points than it is allowed
+
+``rfi_restriction_data_rate_Delta`` (RW)
+ Restricted DDR data rate for RFI protection: Lower Limit
+
+``rfi_restriction_data_rate_Base`` (RW)
+ Restricted DDR data rate for RFI protection: Upper Limit
+
+``ddr_data_rate_point_0`` (RO)
+ DDR data rate selection 1st point
+
+``ddr_data_rate_point_1`` (RO)
+ DDR data rate selection 2nd point
+
+``ddr_data_rate_point_2`` (RO)
+ DDR data rate selection 3rd point
+
+``ddr_data_rate_point_3`` (RO)
+ DDR data rate selection 4th point
+
+``rfi_disable (RW)``
+ Disable DDR rate change feature
+
+DPTF Power supply and Battery Interface
+----------------------------------------
+
+Refer to Documentation/ABI/testing/sysfs-platform-dptf
+
+DPTF Fan Control
+----------------------------------------
+
+Refer to Documentation/admin-guide/acpi/fan_performance_states.rst
diff --git a/Documentation/x86/index.rst b/Documentation/x86/index.rst
index f498f1d36cd3..982c8af853b9 100644
--- a/Documentation/x86/index.rst
+++ b/Documentation/x86/index.rst
@@ -21,6 +21,7 @@ x86-specific Documentation
tlb
mtrr
pat
+ intel-hfi
intel-iommu
intel_txt
amd-memory-encryption
diff --git a/Documentation/x86/intel-hfi.rst b/Documentation/x86/intel-hfi.rst
new file mode 100644
index 000000000000..49dea58ea4fb
--- /dev/null
+++ b/Documentation/x86/intel-hfi.rst
@@ -0,0 +1,72 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+============================================================
+Hardware-Feedback Interface for scheduling on Intel Hardware
+============================================================
+
+Overview
+--------
+
+Intel has described the Hardware Feedback Interface (HFI) in the Intel 64 and
+IA-32 Architectures Software Developer's Manual (Intel SDM) Volume 3 Section
+14.6 [1]_.
+
+The HFI gives the operating system a performance and energy efficiency
+capability data for each CPU in the system. Linux can use the information from
+the HFI to influence task placement decisions.
+
+The Hardware Feedback Interface
+-------------------------------
+
+The Hardware Feedback Interface provides to the operating system information
+about the performance and energy efficiency of each CPU in the system. Each
+capability is given as a unit-less quantity in the range [0-255]. Higher values
+indicate higher capability. Energy efficiency and performance are reported in
+separate capabilities. Even though on some systems these two metrics may be
+related, they are specified as independent capabilities in the Intel SDM.
+
+These capabilities may change at runtime as a result of changes in the
+operating conditions of the system or the action of external factors. The rate
+at which these capabilities are updated is specific to each processor model. On
+some models, capabilities are set at boot time and never change. On others,
+capabilities may change every tens of milliseconds. For instance, a remote
+mechanism may be used to lower Thermal Design Power. Such change can be
+reflected in the HFI. Likewise, if the system needs to be throttled due to
+excessive heat, the HFI may reflect reduced performance on specific CPUs.
+
+The kernel or a userspace policy daemon can use these capabilities to modify
+task placement decisions. For instance, if either the performance or energy
+capabilities of a given logical processor becomes zero, it is an indication that
+the hardware recommends to the operating system to not schedule any tasks on
+that processor for performance or energy efficiency reasons, respectively.
+
+Implementation details for Linux
+--------------------------------
+
+The infrastructure to handle thermal event interrupts has two parts. In the
+Local Vector Table of a CPU's local APIC, there exists a register for the
+Thermal Monitor Register. This register controls how interrupts are delivered
+to a CPU when the thermal monitor generates and interrupt. Further details
+can be found in the Intel SDM Vol. 3 Section 10.5 [1]_.
+
+The thermal monitor may generate interrupts per CPU or per package. The HFI
+generates package-level interrupts. This monitor is configured and initialized
+via a set of machine-specific registers. Specifically, the HFI interrupt and
+status are controlled via designated bits in the IA32_PACKAGE_THERM_INTERRUPT
+and IA32_PACKAGE_THERM_STATUS registers, respectively. There exists one HFI
+table per package. Further details can be found in the Intel SDM Vol. 3
+Section 14.9 [1]_.
+
+The hardware issues an HFI interrupt after updating the HFI table and is ready
+for the operating system to consume it. CPUs receive such interrupt via the
+thermal entry in the Local APIC's Local Vector Table.
+
+When servicing such interrupt, the HFI driver parses the updated table and
+relays the update to userspace using the thermal notification framework. Given
+that there may be many HFI updates every second, the updates relayed to
+userspace are throttled at a rate of CONFIG_HZ jiffies.
+
+References
+----------
+
+.. [1] https://www.intel.com/sdm