diff --git a/Documentation/hwmon/lm90.rst b/Documentation/hwmon/lm90.rst index 953315987c06..78dfc01b47a2 100644 --- a/Documentation/hwmon/lm90.rst +++ b/Documentation/hwmon/lm90.rst @@ -123,6 +123,18 @@ Supported chips: http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3497 + * Maxim MAX6654 + + Prefix: 'max6654' + + Addresses scanned: I2C 0x18, 0x19, 0x1a, 0x29, 0x2a, 0x2b, + + 0x4c, 0x4d and 0x4e + + Datasheet: Publicly available at the Maxim website + + https://www.maximintegrated.com/en/products/sensors/MAX6654.html + * Maxim MAX6657 Prefix: 'max6657' @@ -301,6 +313,13 @@ ADT7461, ADT7461A, NCT1008: * Extended temperature range (breaks compatibility) * Lower resolution for remote temperature +MAX6654: + * Better local resolution + * Selectable address + * Remote sensor type selection + * Extended temperature range + * Extended resolution only available when conversion rate <= 1 Hz + MAX6657 and MAX6658: * Better local resolution * Remote sensor type selection @@ -336,8 +355,8 @@ SA56004X: All temperature values are given in degrees Celsius. Resolution is 1.0 degree for the local temperature, 0.125 degree for the remote -temperature, except for the MAX6657, MAX6658 and MAX6659 which have a -resolution of 0.125 degree for both temperatures. +temperature, except for the MAX6654, MAX6657, MAX6658 and MAX6659 which have +a resolution of 0.125 degree for both temperatures. Each sensor has its own high and low limits, plus a critical limit. Additionally, there is a relative hysteresis value common to both critical |