diff options
Diffstat (limited to 'Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8')
-rw-r--r-- | Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 | 133 |
1 files changed, 0 insertions, 133 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 b/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 deleted file mode 100644 index bac3d0d48b7b..000000000000 --- a/Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8 +++ /dev/null @@ -1,133 +0,0 @@ -What: /sys/bus/iio/devices/iio:deviceX/in_count_count_mode_available -What: /sys/bus/iio/devices/iio:deviceX/in_count_noise_error_available -What: /sys/bus/iio/devices/iio:deviceX/in_count_quadrature_mode_available -What: /sys/bus/iio/devices/iio:deviceX/in_index_index_polarity_available -What: /sys/bus/iio/devices/iio:deviceX/in_index_synchronous_mode_available -KernelVersion: 4.10 -Contact: linux-iio@vger.kernel.org -Description: - This interface is deprecated; please use the Counter subsystem. - - Discrete set of available values for the respective counter - configuration are listed in this file. - -What: /sys/bus/iio/devices/iio:deviceX/in_countY_count_mode -KernelVersion: 4.10 -Contact: linux-iio@vger.kernel.org -Description: - This interface is deprecated; please use the Counter subsystem. - - Count mode for channel Y. Four count modes are available: - normal, range limit, non-recycle, and modulo-n. The preset value - for channel Y is used by the count mode where required. - - Normal: - Counting is continuous in either direction. - - Range Limit: - An upper or lower limit is set, mimicking limit switches - in the mechanical counterpart. The upper limit is set to - the preset value, while the lower limit is set to 0. The - counter freezes at count = preset when counting up, and - at count = 0 when counting down. At either of these - limits, the counting is resumed only when the count - direction is reversed. - - Non-recycle: - Counter is disabled whenever a 24-bit count overflow or - underflow takes place. The counter is re-enabled when a - new count value is loaded to the counter via a preset - operation or write to raw. - - Modulo-N: - A count boundary is set between 0 and the preset value. - The counter is reset to 0 at count = preset when - counting up, while the counter is set to the preset - value at count = 0 when counting down; the counter does - not freeze at the bundary points, but counts - continuously throughout. - -What: /sys/bus/iio/devices/iio:deviceX/in_countY_noise_error -KernelVersion: 4.10 -Contact: linux-iio@vger.kernel.org -Description: - This interface is deprecated; please use the Counter subsystem. - - Read-only attribute that indicates whether excessive noise is - present at the channel Y count inputs in quadrature clock mode; - irrelevant in non-quadrature clock mode. - -What: /sys/bus/iio/devices/iio:deviceX/in_countY_preset -KernelVersion: 4.10 -Contact: linux-iio@vger.kernel.org -Description: - This interface is deprecated; please use the Counter subsystem. - - If the counter device supports preset registers, the preset - count for channel Y is provided by this attribute. - -What: /sys/bus/iio/devices/iio:deviceX/in_countY_quadrature_mode -KernelVersion: 4.10 -Contact: linux-iio@vger.kernel.org -Description: - This interface is deprecated; please use the Counter subsystem. - - Configure channel Y counter for non-quadrature or quadrature - clock mode. Selecting non-quadrature clock mode will disable - synchronous load mode. In quadrature clock mode, the channel Y - scale attribute selects the encoder phase division (scale of 1 - selects full-cycle, scale of 0.5 selects half-cycle, scale of - 0.25 selects quarter-cycle) processed by the channel Y counter. - - Non-quadrature: - The filter and decoder circuit are bypassed. Encoder A - input serves as the count input and B as the UP/DOWN - direction control input, with B = 1 selecting UP Count - mode and B = 0 selecting Down Count mode. - - Quadrature: - Encoder A and B inputs are digitally filtered and - decoded for UP/DN clock. - -What: /sys/bus/iio/devices/iio:deviceX/in_countY_set_to_preset_on_index -KernelVersion: 4.10 -Contact: linux-iio@vger.kernel.org -Description: - This interface is deprecated; please use the Counter subsystem. - - Whether to set channel Y counter with channel Y preset value - when channel Y index input is active, or continuously count. - Valid attribute values are boolean. - -What: /sys/bus/iio/devices/iio:deviceX/in_indexY_index_polarity -KernelVersion: 4.10 -Contact: linux-iio@vger.kernel.org -Description: - This interface is deprecated; please use the Counter subsystem. - - Active level of channel Y index input; irrelevant in - non-synchronous load mode. - -What: /sys/bus/iio/devices/iio:deviceX/in_indexY_synchronous_mode -KernelVersion: 4.10 -Contact: linux-iio@vger.kernel.org -Description: - This interface is deprecated; please use the Counter subsystem. - - Configure channel Y counter for non-synchronous or synchronous - load mode. Synchronous load mode cannot be selected in - non-quadrature clock mode. - - Non-synchronous: - A logic low level is the active level at this index - input. The index function (as enabled via - set_to_preset_on_index) is performed directly on the - active level of the index input. - - Synchronous: - Intended for interfacing with encoder Index output in - quadrature clock mode. The active level is configured - via index_polarity. The index function (as enabled via - set_to_preset_on_index) is performed synchronously with - the quadrature clock on the active level of the index - input. |