diff options
author | Javi Merino <javi.merino@arm.com> | 2014-12-17 14:11:24 +0300 |
---|---|---|
committer | Eduardo Valentin <edubezval@gmail.com> | 2014-12-17 16:00:04 +0300 |
commit | 503ccc3fec4a56cdcfedc507cd1ea0d85e1fbfa2 (patch) | |
tree | 1d2e39ee5a9eb3bf24f02fa9eb8754826ee57859 /include/linux/cpu_cooling.h | |
parent | 2d2e95ea8f124869b96ad929d1701bd64844a06a (diff) | |
download | linux-503ccc3fec4a56cdcfedc507cd1ea0d85e1fbfa2.tar.xz |
thermal: cpu_cooling: return ERR_PTR() for !CPU_THERMAL or !THERMAL_OF
The documentation of of_cpufreq_cooling_register() and
cpufreq_cooling_register() say that they return ERR_PTR() on error.
Accordingly, callers only check for IS_ERR(). Therefore, make them
return ERR_PTR(-ENOSYS) as is customary in the kernel when config
options are missing.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'include/linux/cpu_cooling.h')
-rw-r--r-- | include/linux/cpu_cooling.h | 6 |
1 files changed, 3 insertions, 3 deletions
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h index c303d383def1..bd955270d5aa 100644 --- a/include/linux/cpu_cooling.h +++ b/include/linux/cpu_cooling.h @@ -50,7 +50,7 @@ static inline struct thermal_cooling_device * of_cpufreq_cooling_register(struct device_node *np, const struct cpumask *clip_cpus) { - return NULL; + return ERR_PTR(-ENOSYS); } #endif @@ -65,13 +65,13 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq); static inline struct thermal_cooling_device * cpufreq_cooling_register(const struct cpumask *clip_cpus) { - return NULL; + return ERR_PTR(-ENOSYS); } static inline struct thermal_cooling_device * of_cpufreq_cooling_register(struct device_node *np, const struct cpumask *clip_cpus) { - return NULL; + return ERR_PTR(-ENOSYS); } static inline void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) |