diff options
author | Viresh Kumar <viresh.kumar@linaro.org> | 2015-07-30 10:10:32 +0300 |
---|---|---|
committer | Eduardo Valentin <edubezval@gmail.com> | 2015-08-15 04:26:22 +0300 |
commit | a24af233a1fd09002cabc05d6da248cc5656a2e1 (patch) | |
tree | 3a0dc316c1cd06e65ec744e7886a8028ecedf64c /drivers | |
parent | 166529c9b6f91b97d771e2e7ebf748aadb239b44 (diff) | |
download | linux-a24af233a1fd09002cabc05d6da248cc5656a2e1.tar.xz |
thermal/cpu_cooling: convert 'switch' block to 'if' block in notifier
We just need to take care of single event here and there is no need to
increase indentation level of most of the code (which causes lines
longer that 80 columns to break).
Kill the switch block.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 26 |
1 files changed, 10 insertions, 16 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 093537f00db3..1cf897cd993c 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -221,27 +221,21 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, unsigned long max_freq; struct cpufreq_cooling_device *cpufreq_dev; - switch (event) { + if (event != CPUFREQ_ADJUST) + return NOTIFY_DONE; - case CPUFREQ_ADJUST: - mutex_lock(&cooling_list_lock); - list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { - if (!cpumask_test_cpu(policy->cpu, - &cpufreq_dev->allowed_cpus)) - continue; + mutex_lock(&cooling_list_lock); + list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { + if (!cpumask_test_cpu(policy->cpu, &cpufreq_dev->allowed_cpus)) + continue; - max_freq = cpufreq_dev->cpufreq_val; + max_freq = cpufreq_dev->cpufreq_val; - if (policy->max != max_freq) - cpufreq_verify_within_limits(policy, 0, - max_freq); - break; - } - mutex_unlock(&cooling_list_lock); + if (policy->max != max_freq) + cpufreq_verify_within_limits(policy, 0, max_freq); break; - default: - return NOTIFY_DONE; } + mutex_unlock(&cooling_list_lock); return NOTIFY_OK; } |