thermal: cpu_cooling: fix out of bounds access in time_in_idle
In __cpufreq_cooling_register() we allocate the arrays for time_in_idle
and time_in_idle_timestamp to be as big as the number of cpus in this
cpufreq device. However, in get_load() we access this array using the
cpu number as index, which can result in an out of bound access.
Index time_in_idle{,_timestamp} using the index in the cpufreq_device's
allowed_cpus mask, as we do for the load_cpu array in
cpufreq_get_requested_power()
Reported-by: Nicolas Boichat <drinkcat@chromium.org>
Cc: Amit Daniel Kachhap <amit.kachhap@gmail.com>
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Tested-by: Nicolas Boichat <drinkcat@chromium.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'drivers/thermal')
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 14 |
1 files changed, 8 insertions, 6 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index e3fbc5a5d88f..6ceac4f2d4b2 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -377,26 +377,28 @@ static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_device, * get_load() - get load for a cpu since last updated * @cpufreq_device: &struct cpufreq_cooling_device for this cpu * @cpu: cpu number + * @cpu_idx: index of the cpu in cpufreq_device->allowed_cpus * * Return: The average load of cpu @cpu in percentage since this * function was last called. */ -static u32 get_load(struct cpufreq_cooling_device *cpufreq_device, int cpu) +static u32 get_load(struct cpufreq_cooling_device *cpufreq_device, int cpu, + int cpu_idx) { u32 load; u64 now, now_idle, delta_time, delta_idle; now_idle = get_cpu_idle_time(cpu, &now, 0); - delta_idle = now_idle - cpufreq_device->time_in_idle[cpu]; - delta_time = now - cpufreq_device->time_in_idle_timestamp[cpu]; + delta_idle = now_idle - cpufreq_device->time_in_idle[cpu_idx]; + delta_time = now - cpufreq_device->time_in_idle_timestamp[cpu_idx]; if (delta_time <= delta_idle) load = 0; else load = div64_u64(100 * (delta_time - delta_idle), delta_time); - cpufreq_device->time_in_idle[cpu] = now_idle; - cpufreq_device->time_in_idle_timestamp[cpu] = now; + cpufreq_device->time_in_idle[cpu_idx] = now_idle; + cpufreq_device->time_in_idle_timestamp[cpu_idx] = now; return load; } @@ -598,7 +600,7 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev, u32 load; if (cpu_online(cpu)) - load = get_load(cpufreq_device, cpu); + load = get_load(cpufreq_device, cpu, i); else load = 0; |