diff options
author | Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> | 2022-03-15 01:09:37 +0300 |
---|---|---|
committer | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2022-03-16 21:40:41 +0300 |
commit | c7ff29763989bd09c433f73fae3c1e1c15d9cda4 (patch) | |
tree | 14b7d9de9785e48c066d09a8a2850cd9d1bfd8a2 /drivers/thermal/intel | |
parent | 668f69a5f863b877bc3ae129efe9a80b6f055141 (diff) | |
download | linux-c7ff29763989bd09c433f73fae3c1e1c15d9cda4.tar.xz |
thermal: int340x: Update OS policy capability handshake
Update the firmware with OS supported policies mask, so that firmware can
relinquish its internal controls. Without this update several Tiger Lake
laptops gets performance limited with in few seconds of executing in
turbo region.
The existing way of enumerating firmware policies via IDSP method and
selecting policy by directly writing those policy UUIDS via _OSC method
is not supported in newer generation of hardware.
There is a new UUID "B23BA85D-C8B7-3542-88DE-8DE2FFCFD698" is defined for
updating policy capabilities. As part of ACPI _OSC method:
Arg0 - UUID: B23BA85D-C8B7-3542-88DE-8DE2FFCFD698
Arg1 - Rev ID: 1
Arg2 - Count: 2
Arg3 - Capability buffers: Array of Arg2 DWORDS
DWORD1: As defined in the ACPI 5.0 Specification
- Bit 0: Query Flag
- Bits 1-3: Always 0
- Bits 4-31: Reserved
DWORD2 and beyond:
- Bit0: set to 1 to indicate Intel(R) Dynamic Tuning is active, 0 to
indicate it is disabled and legacy thermal mechanism should
be enabled.
- Bit1: set to 1 to indicate Intel(R) Dynamic Tuning is controlling
active cooling, 0 to indicate bios shall enable legacy thermal
zone with active trip point.
- Bit2: set to 1 to indicate Intel(R) Dynamic Tuning is controlling
passive cooling, 0 to indicate bios shall enable legacy thermal
zone with passive trip point.
- Bit3: set to 1 to indicate Intel(R) Dynamic Tuning is handling
critical trip point, 0 to indicate bios shall enable legacy
thermal zone with critical trip point.
- Bits 4:31: Reserved
From sysfs interface, there is an existing interface to update policy
UUID using attribute "current_uuid". User space can write the same UUID
for ACTIVE, PASSIVE and CRITICAL policy. Driver converts these UUIDs to
DWORD2 Bit 1 to Bit 3. When any of the policy is activated by user
space it is assumed that dynamic tuning is active.
For example
$cd /sys/bus/platform/devices/INTC1040:00/uuids
To support active policy
$echo "3A95C389-E4B8-4629-A526-C52C88626BAE" > current_uuid
To support passive policy
$echo "42A441D6-AE6A-462b-A84B-4A8CE79027D3" > current_uuid
To support critical policy
$echo "97C68AE7-15FA-499c-B8C9-5DA81D606E0A" > current_uuid
To check all the supported policies
$cat current_uuid
3A95C389-E4B8-4629-A526-C52C88626BAE
42A441D6-AE6A-462b-A84B-4A8CE79027D3
97C68AE7-15FA-499c-B8C9-5DA81D606E0A
To match the bit format for DWORD2, rearranged enum int3400_thermal_uuid
and int3400_thermal_uuids[] by swapping current INT3400_THERMAL_ACTIVE
and INT3400_THERMAL_PASSIVE_1.
If the policies are enumerated via IDSP method then legacy method is
used, if not the new method is used to update policy support.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers/thermal/intel')
-rw-r--r-- | drivers/thermal/intel/int340x_thermal/int3400_thermal.c | 146 |
1 files changed, 97 insertions, 49 deletions
diff --git a/drivers/thermal/intel/int340x_thermal/int3400_thermal.c b/drivers/thermal/intel/int340x_thermal/int3400_thermal.c index a0b599100106..4954800b9850 100644 --- a/drivers/thermal/intel/int340x_thermal/int3400_thermal.c +++ b/drivers/thermal/intel/int340x_thermal/int3400_thermal.c @@ -17,8 +17,8 @@ #define INT3400_KEEP_ALIVE 0xA0 enum int3400_thermal_uuid { + INT3400_THERMAL_ACTIVE = 0, INT3400_THERMAL_PASSIVE_1, - INT3400_THERMAL_ACTIVE, INT3400_THERMAL_CRITICAL, INT3400_THERMAL_ADAPTIVE_PERFORMANCE, INT3400_THERMAL_EMERGENCY_CALL_MODE, @@ -31,8 +31,8 @@ enum int3400_thermal_uuid { }; static char *int3400_thermal_uuids[INT3400_THERMAL_MAXIMUM_UUID] = { - "42A441D6-AE6A-462b-A84B-4A8CE79027D3", "3A95C389-E4B8-4629-A526-C52C88626BAE", + "42A441D6-AE6A-462b-A84B-4A8CE79027D3", "97C68AE7-15FA-499c-B8C9-5DA81D606E0A", "63BE270F-1C11-48FD-A6F7-3AF253FF3E2D", "5349962F-71E6-431D-9AE8-0A635B710AEE", @@ -59,6 +59,7 @@ struct int3400_thermal_priv { char *data_vault; int odvp_count; int *odvp; + u32 os_uuid_mask; struct odvp_attr *odvp_attrs; }; @@ -142,12 +143,55 @@ static ssize_t current_uuid_show(struct device *dev, struct device_attribute *devattr, char *buf) { struct int3400_thermal_priv *priv = dev_get_drvdata(dev); + int i, length = 0; + + if (priv->current_uuid_index > 0) + return sprintf(buf, "%s\n", + int3400_thermal_uuids[priv->current_uuid_index]); + + for (i = 0; i <= INT3400_THERMAL_CRITICAL; i++) { + if (priv->os_uuid_mask & BIT(i)) + length += scnprintf(&buf[length], + PAGE_SIZE - length, + "%s\n", + int3400_thermal_uuids[i]); + } - if (priv->current_uuid_index == -1) - return sprintf(buf, "INVALID\n"); + if (length) + return length; - return sprintf(buf, "%s\n", - int3400_thermal_uuids[priv->current_uuid_index]); + return sprintf(buf, "INVALID\n"); +} + +static int int3400_thermal_run_osc(acpi_handle handle, char *uuid_str, int *enable) +{ + u32 ret, buf[2]; + acpi_status status; + int result = 0; + struct acpi_osc_context context = { + .uuid_str = NULL, + .rev = 1, + .cap.length = 8, + }; + + context.uuid_str = uuid_str; + + buf[OSC_QUERY_DWORD] = 0; + buf[OSC_SUPPORT_DWORD] = *enable; + + context.cap.pointer = buf; + + status = acpi_run_osc(handle, &context); + if (ACPI_SUCCESS(status)) { + ret = *((u32 *)(context.ret.pointer + 4)); + if (ret != *enable) + result = -EPERM; + } else + result = -EPERM; + + kfree(context.ret.pointer); + + return result; } static ssize_t current_uuid_store(struct device *dev, @@ -164,16 +208,47 @@ static ssize_t current_uuid_store(struct device *dev, * If we have a list of supported UUIDs, make sure * this one is supported. */ - if (priv->uuid_bitmap && - !(priv->uuid_bitmap & (1 << i))) + if (priv->uuid_bitmap & BIT(i)) { + priv->current_uuid_index = i; + return count; + } + + /* + * There is support of only 3 policies via the new + * _OSC to inform OS capability: + * INT3400_THERMAL_ACTIVE + * INT3400_THERMAL_PASSIVE_1 + * INT3400_THERMAL_CRITICAL + */ + + if (i > INT3400_THERMAL_CRITICAL) return -EINVAL; - priv->current_uuid_index = i; - return count; + priv->os_uuid_mask |= BIT(i); + + break; } } - return -EINVAL; + if (priv->os_uuid_mask) { + int cap, ret; + + /* + * Capability bits: + * Bit 0: set to 1 to indicate DPTF is active + * Bi1 1: set to 1 to active cooling is supported by user space daemon + * Bit 2: set to 1 to passive cooling is supported by user space daemon + * Bit 3: set to 1 to critical trip is handled by user space daemon + */ + cap = ((priv->os_uuid_mask << 1) | 0x01); + ret = int3400_thermal_run_osc(priv->adev->handle, + "b23ba85d-c8b7-3542-88de-8de2ffcfd698", + &cap); + if (ret) + return ret; + } + + return count; } static DEVICE_ATTR_RW(current_uuid); @@ -236,41 +311,6 @@ end: return result; } -static int int3400_thermal_run_osc(acpi_handle handle, - enum int3400_thermal_uuid uuid, bool enable) -{ - u32 ret, buf[2]; - acpi_status status; - int result = 0; - struct acpi_osc_context context = { - .uuid_str = NULL, - .rev = 1, - .cap.length = 8, - }; - - if (uuid < 0 || uuid >= INT3400_THERMAL_MAXIMUM_UUID) - return -EINVAL; - - context.uuid_str = int3400_thermal_uuids[uuid]; - - buf[OSC_QUERY_DWORD] = 0; - buf[OSC_SUPPORT_DWORD] = enable; - - context.cap.pointer = buf; - - status = acpi_run_osc(handle, &context); - if (ACPI_SUCCESS(status)) { - ret = *((u32 *)(context.ret.pointer + 4)); - if (ret != enable) - result = -EPERM; - } else - result = -EPERM; - - kfree(context.ret.pointer); - - return result; -} - static ssize_t odvp_show(struct kobject *kobj, struct kobj_attribute *attr, char *buf) { @@ -426,10 +466,18 @@ static int int3400_thermal_change_mode(struct thermal_zone_device *thermal, if (!priv) return -EINVAL; - if (mode != thermal->mode) + if (mode != thermal->mode) { + int enabled; + + if (priv->current_uuid_index < 0 || + priv->current_uuid_index >= INT3400_THERMAL_MAXIMUM_UUID) + return -EINVAL; + + enabled = (mode == THERMAL_DEVICE_ENABLED); result = int3400_thermal_run_osc(priv->adev->handle, - priv->current_uuid_index, - mode == THERMAL_DEVICE_ENABLED); + int3400_thermal_uuids[priv->current_uuid_index], + &enabled); + } evaluate_odvp(priv); |