regulator: pwm: Fix machine constraints application
If the zero duty cycle doesn't correspond to any voltage in the voltage table, the PWM regulator returns an -EINVAL from get_voltage_sel() which results in the core erroring out with a "failed to get the current voltage" and ending up not applying the machine constraints. Instead, return -ENOTRECOVERABLE which makes the core set the voltage since it's at an unknown value. For example, with this device tree: fooregulator { compatible = "pwm-regulator"; pwms = <&foopwm 0 100000>; regulator-min-microvolt = <2250000>; regulator-max-microvolt = <2250000>; regulator-name = "fooregulator"; regulator-always-on; regulator-boot-on; voltage-table = <2250000 30>; }; Before this patch: fooregulator: failed to get the current voltage(-22) After this patch: fooregulator: Setting 2250000-2250000uV fooregulator: 2250 mV Signed-off-by: Vincent Whitchurch <vincent.whitchurch@axis.com> Link: https://lore.kernel.org/r/20200902130952.24880-1-vincent.whitchurch@axis.com Signed-off-by: Mark Brown <broonie@kernel.org>
Diffstat (limited to 'drivers/regulator')
-rw-r--r--drivers/regulator/pwm-regulator.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/regulator/pwm-regulator.c b/drivers/regulator/pwm-regulator.c
index 3234b118b53e..990bd50771d8 100644
--- a/drivers/regulator/pwm-regulator.c
+++ b/drivers/regulator/pwm-regulator.c
@@ -279,7 +279,7 @@ static int pwm_regulator_init_table(struct platform_device *pdev,
return ret;
}
- drvdata->state = -EINVAL;
+ drvdata->state = -ENOTRECOVERABLE;
drvdata->duty_cycle_table = duty_cycle_table;
drvdata->desc.ops = &pwm_regulator_voltage_table_ops;