diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2021-04-29 01:50:24 +0300 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2021-04-29 01:50:24 +0300 |
commit | 0080665fbd0e6a771aee366bb2aa208626e43def (patch) | |
tree | 26694bbbf64ad79186da20f7c1b39c7eec851595 /drivers/of/unittest-data/overlay_base.dts | |
parent | 5a69e9bce9984806029926f405b4517878e703e2 (diff) | |
parent | 031cc263c037a95e5d1249cbd3d55b77021f1eb8 (diff) | |
download | linux-0080665fbd0e6a771aee366bb2aa208626e43def.tar.xz |
Merge tag 'devicetree-for-5.13' of git://git.kernel.org/pub/scm/linux/kernel/git/robh/linux
Pull devicetree updates from Rob Herring:
- Refactor powerpc and arm64 kexec DT handling to common code. This
enables IMA on arm64.
- Add kbuild support for applying DT overlays at build time. The first
user are the DT unittests.
- Fix kerneldoc formatting and W=1 warnings in drivers/of/
- Fix handling 64-bit flag on PCI resources
- Bump dtschema version required to v2021.2.1
- Enable undocumented compatible checks for dtbs_check. This allows
tracking of missing binding schemas.
- DT docs improvements. Regroup the DT docs and add the example schema
and DT kernel ABI docs to the doc build.
- Convert Broadcom Bluetooth and video-mux bindings to schema
- Add QCom sm8250 Venus video codec binding schema
- Add vendor prefixes for AESOP, YIC System Co., Ltd, and Siliconfile
Technologies Inc.
- Cleanup of DT schema type references on common properties and
standard unit properties
* tag 'devicetree-for-5.13' of git://git.kernel.org/pub/scm/linux/kernel/git/robh/linux: (64 commits)
powerpc: If kexec_build_elf_info() fails return immediately from elf64_load()
powerpc: Free fdt on error in elf64_load()
of: overlay: Fix kerneldoc warning in of_overlay_remove()
of: linux/of.h: fix kernel-doc warnings
of/pci: Add IORESOURCE_MEM_64 to resource flags for 64-bit memory addresses
dt-bindings: bcm4329-fmac: add optional brcm,ccode-map
docs: dt: update writing-schema.rst references
dt-bindings: media: venus: Add sm8250 dt schema
of: base: Fix spelling issue with function param 'prop'
docs: dt: Add DT API documentation
of: Add missing 'Return' section in kerneldoc comments
of: Fix kerneldoc output formatting
docs: dt: Group DT docs into relevant sub-sections
docs: dt: Make 'Devicetree' wording more consistent
docs: dt: writing-schema: Include the example schema in the doc build
docs: dt: writing-schema: Remove spurious indentation
dt-bindings: Fix reference in submitting-patches.rst to the DT ABI doc
dt-bindings: ddr: Add optional manufacturer and revision ID to LPDDR3
dt-bindings: media: video-interfaces: Drop the example
devicetree: bindings: clock: Minor typo fix in the file armada3700-tbg-clock.txt
...
Diffstat (limited to 'drivers/of/unittest-data/overlay_base.dts')
-rw-r--r-- | drivers/of/unittest-data/overlay_base.dts | 90 |
1 files changed, 1 insertions, 89 deletions
diff --git a/drivers/of/unittest-data/overlay_base.dts b/drivers/of/unittest-data/overlay_base.dts index 99ab9d12d00b..ab9014589c5d 100644 --- a/drivers/of/unittest-data/overlay_base.dts +++ b/drivers/of/unittest-data/overlay_base.dts @@ -2,92 +2,4 @@ /dts-v1/; /plugin/; -/* - * Base device tree that overlays will be applied against. - * - * Do not add any properties in node "/". - * Do not add any nodes other than "/testcase-data-2" in node "/". - * Do not add anything that would result in dtc creating node "/__fixups__". - * dtc will create nodes "/__symbols__" and "/__local_fixups__". - */ - -/ { - testcase-data-2 { - #address-cells = <1>; - #size-cells = <1>; - - electric_1: substation@100 { - compatible = "ot,big-volts-control"; - reg = < 0x00000100 0x100 >; - status = "disabled"; - - hvac_1: hvac-medium-1 { - compatible = "ot,hvac-medium"; - heat-range = < 50 75 >; - cool-range = < 60 80 >; - }; - - spin_ctrl_1: motor-1 { - compatible = "ot,ferris-wheel-motor"; - spin = "clockwise"; - rpm_avail = < 50 >; - }; - - spin_ctrl_2: motor-8 { - compatible = "ot,roller-coaster-motor"; - }; - }; - - rides_1: fairway-1 { - #address-cells = <1>; - #size-cells = <1>; - compatible = "ot,rides"; - status = "disabled"; - orientation = < 127 >; - - ride@100 { - #address-cells = <1>; - #size-cells = <1>; - compatible = "ot,roller-coaster"; - reg = < 0x00000100 0x100 >; - hvac-provider = < &hvac_1 >; - hvac-thermostat = < 29 > ; - hvac-zones = < 14 >; - hvac-zone-names = "operator"; - spin-controller = < &spin_ctrl_2 5 &spin_ctrl_2 7 >; - spin-controller-names = "track_1", "track_2"; - queues = < 2 >; - - track@30 { - reg = < 0x00000030 0x10 >; - }; - - track@40 { - reg = < 0x00000040 0x10 >; - }; - - }; - }; - - lights_1: lights@30000 { - compatible = "ot,work-lights"; - reg = < 0x00030000 0x1000 >; - status = "disabled"; - }; - - lights_2: lights@40000 { - compatible = "ot,show-lights"; - reg = < 0x00040000 0x1000 >; - status = "disabled"; - rate = < 13 138 >; - }; - - retail_1: vending@50000 { - reg = < 0x00050000 0x1000 >; - compatible = "ot,tickets"; - status = "disabled"; - }; - - }; -}; - +#include "overlay_common.dtsi" |