summaryrefslogtreecommitdiff
path: root/drivers/nvme
diff options
context:
space:
mode:
authorMax Gurtovoy <maxg@mellanox.com>2020-03-09 18:04:12 +0300
committerKeith Busch <kbusch@kernel.org>2020-03-25 22:51:54 +0300
commit2db24e4a22bc97c713261a81fc75e2a36db65715 (patch)
tree8282f56d98e92a3e1dd0f57a5e872d2d2b8e672d /drivers/nvme
parent761ad26c45b0260a8516bc1fc9d25bb66ca4e25c (diff)
downloadlinux-2db24e4a22bc97c713261a81fc75e2a36db65715.tar.xz
nvme-pci: properly print controller address
Align PCI address print with fabrics address that is printed with newline character. Before: [root@server40 linux]# cat /sys/class/nvme/nvme2/address 0000:0b:00.0[root@server40 linux]# After: [root@server40 linux]# cat /sys/class/nvme/nvme2/address 0000:0b:00.0 [root@server40 linux]# Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Max Gurtovoy <maxg@mellanox.com>
Diffstat (limited to 'drivers/nvme')
-rw-r--r--drivers/nvme/host/pci.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/nvme/host/pci.c b/drivers/nvme/host/pci.c
index f45e26e6af7e..e6fa0c7bb96c 100644
--- a/drivers/nvme/host/pci.c
+++ b/drivers/nvme/host/pci.c
@@ -2656,7 +2656,7 @@ static int nvme_pci_get_address(struct nvme_ctrl *ctrl, char *buf, int size)
{
struct pci_dev *pdev = to_pci_dev(to_nvme_dev(ctrl)->dev);
- return snprintf(buf, size, "%s", dev_name(&pdev->dev));
+ return snprintf(buf, size, "%s\n", dev_name(&pdev->dev));
}
static const struct nvme_ctrl_ops nvme_pci_ctrl_ops = {